Download Print this page

General Lock WP-380 User Manual page 2

Wp-380 a ccd camera

Advertisement

9. Our factory settings is for you to get the best image within 3~5 Meters. If it is out
of focus, you can also adjust the focus according the following procedures.
a. Remove the three fixing screws, which hold the housing cover.
b. Carefully pull the housing cover from the back plate.
(Please pay attention to prevent damage to the "O"-Ring seal.)
c. Loosen the lens mount fixing screw located at side of the lens by using the
L Wrench (supplied).
d. Adjust the lens to bring the subject into focus.
e. Secure the lens mount fixing screw firmly again.
f. Overlaying the cover gently in order to prevent damage to the "O"-Ring and
camera components.
Notes:
(A)Make wiring connections only after it has been determined that power has
been disconnected. Use only a 12VDC power supply for the WP-380 series
(300 mA minimum recommended).
(B)There is a desiccant pack attached to the housing base under the camera,
which is designed to absorb any moisture trapped inside the housing during
adjustment. To avoid excessive moisture build up, it is recommended that the
camera not be installed in rainy or excessively damp conditions. It is also
advisable to limit the number of times the housing cover is removed. The
desiccant pack can be replaced if condensation develops inside the housing.
WP-380 Users Manual and Installation Instructions

Advertisement