12 DIAGNOSTICS SYSTEM

12.1 Access to diagnostics system

Using a single procedure, it is possible to access to the diagnostics system. After accessing this function,
the following operations can be performed:
control of the operation of each of the components in the appliance
read / cancel the alarms
The diagnostics cycles are available only if the communication between the main PCB and the display
board is correct; moreover there should not be configuration errors of the appliance.
To access:
1. Cancel the set programme and switch the appliance off.
2. Press the start/pause and exit buttons simultaneously, then, holding them down,
switch the appliance on rotating the programme selector of one position
clockwise.
3. Hold the START/PAUSE and EXIT buttons down up to DIAGNOSTIC MODE
appears (about 5 seconds).
In the first position the function test of the buttons and the corresponding LEDs is performed; by rotating
the programme selector clockwise the operation diagnostics of each component and the reading of the
alarms is carried out.

12.2 Exiting diagnostics system

To exit the diagnostics system switch the appliance off, on and then off again.

12.3 Phases of the diagnostics test

After activating the diagnostics system, the operation diagnostics of the different components and the
reading of the alarms can be performed, by rotating the selector clockwise.
In the diagnostics cycle all alarms are activated. If during the cycle operation an alarm occurs, the
appliance blocks and the code of the relative alarm appears.