Summary of Contents for Brunton ADC-Summit

  • Page 1: User Manual

    06MAR 12:38.28 88.2% 28.0 User Manual Downloaded from www.Manualslib.com manuals search engine...
  • Page 2: General Guide

    1.0 General Guide Thank you for purchasing your new ADC. We recommend reading this manual, and WARNING ! practicing the operations before using your Make sure that you fully understand the ADC in the field. functions and limitations of the ADC before relying on it.
  • Page 3: Care And Maintenance

    2.0 Care and Maintenance Prevent getting dirt in the ADC propeller. It could clog the mechanism. Avoid exposing this product to extreme heat or extreme cold for an unreasonable amount of time. Avoid severe impacts to the ADC. Store the ADC in a dry place when it is not in use.
  • Page 4: Part Description

    3.0 Part description North Orientation blade (RED) 1st row 06MAR 2nd row 12:38.28 3rd row 88.2% 28.0 4nd row Propeller Propeller blades 06MAR Display 12:38.28 88.2% 28.0 [mode] [light] Infrared Port (send data from this product to PC via [set] Buttons this port) [reset]...
  • Page 5: Button Operation Summary

    4.0 Button Operation Summary 1 [mode] Button Press the mode button to select among the [mode] major function modes In function modes: Press and hold the mode button to select setting display In any setting display: Press the mode button to select among different settings.
  • Page 6 4.1 Button Operation Summary 2 [reset] Button In Chronograph Mode (counting): Press the reset button to get Lap Time Display. In Chronograph Mode (stop-counting): Press the reset button to reset the display to zero. In Timer Mode (stop-counting): Press the [light] reset button to reset the timer to target time.
  • Page 7 5.0 Major Functional Modes [set] 06MAR BARO TEMP WIND DAILY ALARM [mode] [mode] [mode] 12:38.28 12:00 1001.3 28.3 21.3 88.2% 28.0 18.2 13.2 18.3 Barometer Mode Wind Mode Current Time Mode Daily Alarm Mode Temperature Mode [mode] [mode] [mode] [mode] ALTITUDE m DATALOG RACE TIMER...
  • Page 8: Current Time Mode

    Current Time Mode - Functional Displays Functional Displays Weather Current Time Mode includes three different Forecast Date 06MAR displays: the Weather Forecast Display, Symbol Altitude Display and Barometer Display. Current Day of week 12:38.28 The above displays rotate through every 5 Time 88.2% 28.0...
  • Page 9 Current Time Mode - Setting the Current Time Mode To Select Setting Display Setting the current time and date, and their 06MAR display formats, press and hold the [mode] reset Second to zero button for about 2 seconds to select the 12:38.28 setting display (the '12' indicator will start 88.2%...
  • Page 10 Current Time Mode - Weather Forecast Symbols Weather Forecast Symbol The ADC includes a weather forecast function Weather Forecast Symbols that predicts the weather for the next 12 hours. The ADC will display the forecasted weather by the weather forecast symbol. There are five Sunny Partial Cloudy Rainy Stormy kind of weather forecast symbols, they are the...
  • Page 11: Daily Alarm Mode

    7.0 Daily Alarm Mode - Daily Alarm Display Daily Alarm Display Mode indicator In Daily Alarm Mode, the display will show DAILY ALARM the following: Alarm ON/OFF DAILY ALARM 1) The mode indicator ' ' appears 12:00 Status on the 1st row of the display. Alarm time 2) The ' ' or '...
  • Page 12 7.1 Daily Alarm Mode - Setting the Daily Alarm Mode To Select the Setting Display Setting the Daily Alarm Time, press and hold the [mode] button for about 2 seconds DAILY ALARM scroll the scroll to select the setting display (the 'minute' setting by the setting increment of 1...
  • Page 13: Chronograph Mode

    8.0 Chronograph Mode - Chronograph Display Chronograph Function The ADC is equipped with a Chronograph Mode Indicator CHRONO Mode, it can measure 3 different periods of Chronograph GRAPH time. They are: Time (second) Chronograph 0:00.00 Time (hour) 1) Elapsed time, 2) Accumulative elapsed time Chronograph Time Chronograph...
  • Page 14: Using The Chronograph

    8.1 Chronograph Mode - Using the Chronograph Chronograph Function Lap Time In 'Zero' Display, press the [set] button once CHRONO (the chronograph to start the counting. When it is counting, is counting in the RUNNING background) press the [set] button again to stop the 0:00.00 counting, and the elapsed time of which the chronograph is counting will appear.
  • Page 15 8.2 Chronograph Mode - Recall the Lap Time To Recall the Lap Time Select the lap time by Select the lap time by In Stop Counting Display, press and hold backward scrolling backward scrolling (fast scrolling) (1 lap per step) the [mode] button to select the Chronograph Recall Display.
  • Page 16 9.0 Race Timer Mode - Race Timer Display The Target Time Mode The ADC is equipped with a countdown timer to RACE TIMER Indicator keep track of a fixed period of time (target time). The user can set a target time of up to 99 hours, 0:10.00 59 minutes 59 seconds.
  • Page 17 9.1 Race Timer Mode - Setting the Race Timer Mode To Select the Setting Display Setting the target time in Race Timer Mode, RACE TIMER press and hold the [mode] button for about 2 seconds to select the setting display (the scroll through scroll the scroll...
  • Page 18 9.2 Race Timer Mode - Using the Race Timer To Use the Race Timer RACE TIMER RACE TIMER Once a target time has been set, press the beeps STOPPED [set] button once to start the countdown. 0:10.00 0:00.00 When it is running, press the [set] button stop again to stop the countdown.
  • Page 19 10.0 Sensor Functions Mode - Manual Data Log Function Data Log Function BARO WIND Km/H TEMP The ADC is equipped with a function to log the sensor functional mode readings. They 1001.3 21.3 28.3 are the current wind speed, ambient 18.3 18.2 13.2...
  • Page 20 11.0 Wind Speed Mode - Before Using the Wind Speed Mode How Wind Speed is Measured the propeller blades are entirely The ADC is equipped with a propeller that is exposed to air similar to a traditional aerovane. When the propeller faces the wind, it rotates and generates signal.
  • Page 21 11.1 Wind Speed Mode - Wind Speed Mode Function Wind Speed Mode Functions ! This ADC has the following wind speed Current, Max Beaufort functions: and Average Scale Wind Speed 1) The Beaufort Scale: The longest and most widely used set of criteria to describe the wind conditions.
  • Page 22 11.2 Wind Speed Mode - Wind Speed Display Wind Speed Display Mode In Wind Speed Mode, the display will show Wind Indicator Speed Unit the following: WIND WIND 1) The ' ' Indicator and the wind speed Beaufort unit appear on the 1st row of the display. Scale Current 21.3...
  • Page 23 11.3 Wind Speed Mode - What is Beaufort Scale? What is Beaufort Scale? Beaufort Scale is the longest and most widely used set of criteria to describe the WIND wind conditions and its effects on land as Beaufort well as on sea. Scale 21.3 (by average...
  • Page 24 11.4 Wind Speed Mode - Beaufort Scale Table Downloaded from www.Manualslib.com manuals search engine...
  • Page 25 11.5 Wind Speed Mode - Wind Speed Display Lock, Reset Max Wind Speed Wind Speed Display Lock The ADC is equipped with a function to hold WIND mph the fluctuating wind speed reading on the display. 21.3 In Wind Speed Mode, press the [set] button 18.3 to lock the wind speed reading (the display will hold the current reading for 5 seconds).
  • Page 26 11.6 Wind Speed Mode - Wind Speed Alarm Wind Speed Alarm Wind Speed The ADC is equipped with a wind speed 'beep' for 5 alarm. seconds That alarm alerts user when the current (every 2 Alarm Range minutes) wind speed is equal to or higher than the preset wind speed level.
  • Page 27 11.7 Wind Speed Mode - Setting the Wind Speed Alarm and Time Span To Set the Wind Speed Alarm, and Time Span Wind Speed Alarm and for Average Wind Speed Calculation hold Time Span Setting Sequence [mode] To set the wind speed alarm, press and hold WIND mph [mode] the [mode] button for about 2 seconds to...
  • Page 28 11.8 Wind Speed Mode - Using the Propeller as a Mechanical Compass Propeller as a Mechanical Compass The ADC measures ambient temperature, wind speed, and it also tells compass North East directions. North Target object One of the propeller blades is red-colored to pole indicate the magnetic north pole.
  • Page 29 12.0 Temperature - Temperature Functions Temperature Mode Functions ! The ADC has the following temperature functions: Current, Minimum Current Wind Chill 1) The Current Temperature: The Current Temperature Temperature Temperature readings. 2) The Current and Minimum Wind Chill t e m p e r a t u r e : T h e w i n d e f f e c t o n t e m p e r a t u r e .
  • Page 30: Temperature Display

    12.1 Temperature - Temperature Display Temperature Display In Temperature Mode, the display will show Mode Temperature the following: Indicator Unit TEMP TEMP 1) The ' ' Indicator and the temperature Current unit appear on the 1st row of the display. Temperature 28.3 2) The Current Temperature appears on the...
  • Page 31: Temperature Mode

    12.2 Temperature Mode- Wind Chill Temperature What is Wind Chill Temperature Wind chill is a temperature factor that Current Wind Chill combines air temperature and the effect of Wind Temperature Temperature Case Conditions Weather blowing wind. As blowing wind makes you feel as though the temperature is lower than simple air NO wind 15F/ -9.4C...
  • Page 32 12.3 Temperature Mode - To Reset Minimum Wind Chill Temperature To R e s e t t h e M i n i m u m W i n d C h i l l Temperature TEMP To reset the minimum wind chill temperature, press and hold the [reset] button for 2 28.3 seconds to select the Reset Display.
  • Page 33 12.4 Temperature Mode - Temperature History Graph for the Last 24 Hours Temperature History Graph TEMP The ADC is equipped with a temperature memory function. It records the last 24-hour temperature and displays them by bar-graph. 28.3 18.2 13.2 In Temperature Mode, press the [set] button to select the Temperature History Graph Temperature Mode Display.
  • Page 34 12.5 Temperature Mode - Wind Chill Temperature Alarm Wind Chill Temperature Alarm Wind Chill The ADC is equipped with a wind chill Temperature temperature alarm. That alarm alerts user when the current wind chill temperature is equal to or lower than the preset wind chill temperature level.
  • Page 35 12.6 Temperature Mode - Setting the Wind Chill Temperature Alarm To Select Setting Display Wind Chill Temperature Alarm and hold To select the setting display, press and hold Temperature Calibration [mode] Setting Sequence the [mode] button for about 2 seconds to TEMP [mode] select the setting display (temperature digits...
  • Page 36 12.7 Temperature Mode - Calibrating the Temperature To Select Setting Display Following the previous ' Setting the Wind TEMP Chill Temperature Alarm ' section to select OFFSET the Calibration Display. In the Calibration Display, press and hold 18.3 the [reset] button for 2 seconds to select the Calibration Setting Display.
  • Page 37: Barometer Mode

    13.0 Barometer Mode - Barometer Mode Function Barometer Mode Functions ! The ADC has the following barometric pressure functions: 24 Hour Pressure Stormy Alarm 1) The 24-Hour Pressure History Graph: History Graph The Barometric Pressure Memory for the last 24 hours. 2) Storm Alarm: The alarm that alerts the user when the upcoming weather is stormy.
  • Page 38: Barometer Display

    13.1 Barometer Mode - Barometer Display Barometer Display Mode Pressure In Barometer Mode, the display will show the Indicator Unit following: BARO BARO Current 1) The mode indicator ' ' Indicator and Barometric 1001.3 the barometric pressure unit appear on the Pressure 1st row of the display.
  • Page 39 13.2 Barometer Mode - Pressure History Graph for the Last 24 Hours Pressure History Graph The ADC is equipped with a barometric BARO pressure memory function. It records the last 24 hours barometric pressure readings, and 1001.3 it can display them by bar-graph. In Barometer Mode, press the [set] button to select the Pressure History Graph Display.
  • Page 40 13.3 Barometer Mode - About Storm Alarm About Stormy Alarm The alarm gives beep alert when the ADC Weather Forecast Symbols predicts the upcoming weather as stormy. Then, in the Current time - Weather Forecast Display, the 'stormy' weather forecast symbol will appear. Stormy Storm Alarm Sound beep...
  • Page 41 13.4 Barometer Mode - Setting the Storm Alarm Select the Setting Display hold Storm Alarm and Pressure Press and hold the [mode] button for about [mode] Calibration Setting Sequence 2 second to select the setting display (the BARO [mode] ' or ' ' will start flashing).
  • Page 42 13.5 Barometer Mode - Calibrating the Barometric Pressure To Calibrate the Barometric Pressure Following the previous 'Setting the Storm Alarm' section to select the Calibration Display. BARO OFFSET In the Calibration Display, press and hold the [reset] button for 2 seconds to select the 1001.3 Calibration Setting Display.
  • Page 43: Altimeter Mode

    14.0 Altimeter Mode - Altimeter Mode Functions Altimeter Mode Functions This mode has the following functions: 1) The different altitude readings: Current, Accumulative Current, Min & Minimum and Maximum Altitude. Ascend & Descend Max Altitude Altitude 2) The Accumulative Ascend and Descent Altitude: The sums of the ascending/ descending distance for ski sport.
  • Page 44: Altitude Mode

    14.1 Altitude Mode - Functional Displays unctional Displays Ski Run Altimeter Mode includes three different ALTITUDE m number functional displays, they are the Ski-Run SKI RUN: 99 Display, Max-Min Display and Air-Density Accumulated Display. Descent 2237 2418 In Altimeter Mode, press the [set] button to select between the above displays following Accumulated Ski-Run Display...
  • Page 45 14.2 Altimeter Mode - To Change Altitude Units To Change Altitude Units The ADC can display altitude in the following units: 1) Meter (m) 2) Feet (ft). [reset] In any of the functional displays (Ski-Run, Max-Min and Air-Density Display), press the [reset] button to select the altitude unit following the adjacent diagram.
  • Page 46 14.3.0 Altimeter Mode - Altitude Ski-Run Display Ski-Run Display Altitude Mode The ADC is equipped with functions to register unit Indicator ski runs. They are the Ski-Run Counter, ALTITUDE m Ski Run SKI RUN: 99 A c c u m u l a t i v e A s c e n d i n g A l t i t u d e a n d Current counter Accumulative Descending Altitude.
  • Page 47 14.3.1 Altimeter Mode - To Turn Ski-Run Function ON and OFF To Turn Ski-Run Function ON and OFF Ski-Run Function ON-OFF Setting To select the setting display, press and hold Function OFF Function ON the [reset] button for about 2 seconds (the 'YES' or 'NO' will start flashing).
  • Page 48 14.3.2 Altimeter Mode - To Reset the Ski-Run Counter, Ascend & Descend To Reset Ski-Run Counter, Ascending and SKIRUN SKIRUN Descending Altitude. RESET? RESET? [set] Following the previous 'To Turn Ski-Run ALTITUDE m Function ON and OFF' section to enter the SKI RUN: 99 Ski-Run Reset Setting.
  • Page 49 14.4.0 Altimeter Mode - Altitude Max-Min Functions Altitude Max-Min Display ! Altitude Max-Min Display includes three Highest point Highest point altitude (m) d i f f e r e n t a l t i t u d e r e a d i n g s : C u r r e n t , Minimum and Maximum Altitude.
  • Page 50 14.4.1 Altimeter Mode - To Reset Minimum and Maximum Altitude To Reset the Maximum and Minimum Altitude ALTITUDE m To reset the maximum and minimum altitude, press and hold the [reset] button for about 2 seconds to select the Reset Display. When the Minimum Altitude Reset Display is hold displaying, press the [mode] button to select...
  • Page 51: Altitude Alarm

    14.5 Altimeter Mode - Altitude Alarm Altitude Alarm Altitude The ADC is equipped with an altitude alarm. That alarm alerts user when the current altitude is equal to or higher than the preset 'beep' Undesirable Range altitude level. for 5 seconds preset Check the 'Setting the Altimeter Mode'...
  • Page 52 14.6.0 Altimeter Mode - Altitude Mode Setting Altimeter Mode Setting The following functions can be performed in hold [mode] [mode] the Altimeter Setting Mode. ALTITUDE m Altitude Altitude 1) Altitude Alarm Settings, Alarm Calibration a) ON or OFF Setting Display b) Target Altitude Level for alarm hold [mode]...
  • Page 53: Setting The Altitude Alarm

    14.6.1 Altimeter Mode - Setting the Altitude Alarm To Set the Altitude Alarm Altitude Alarm Setting Following the previous 'Altimeter Mode Alarm ON Alarm OFF Setting Sequence' to select the Altitude Alarm Setting Display. ALTITUDE m ALTITUDE m W.CHILL When the altitude alarm digits are flashing, [set] press the [reset] button to scroll by 1 to - - - -...
  • Page 54: Calibrating The Altitude

    14.6.2 Altimeter Mode - Calibrating the Altitude To Calibrate the Altitude Following the previous 'Altimeter Mode Setting Sequence' enter the Calibration ALTITUDE m Display. When the Calibration Display ADJUST the offset value appears, press and hold the [reset] button for about 2 seconds to select the Calibration the current Setting Display.
  • Page 55: Data Log Mode

    15.0 Data Log Mode - Data Log Function Data Log Function The ADC is equipped with a function to log the sensor functional mode data. These record data are the current wind speed, ambient data data data temperature, barometric pressure, relative Free Memory Display humidity and the altitude at the current Data Log Display...
  • Page 56 15.1 Data Log Mode - Data Log Display and Free Memory Display Functional Displays Data Log Mode includes two different functional displays; they are the Free DATALOG the date that the time that Memory Display and Data Log Display. this record this record 06 MAR 2003 was logged...
  • Page 57 15.2 Data Log Mode - Automatic Data Log To Log Data Automatically (Auto-Log) Press and hold the [set] button for about 2 seconds in the Data Log Mode to enable or DATALOG DATALOG disable the automatic log function. 06 MAR 2003 06 MAR 2003 hold [set] When the function is enabled, a 'LOG' indicator...
  • Page 58 15.3 Data Log Mode - Data and Record Administration Log a New Data When a new data is logged, this data will become the last one of the data list. data 1 data 1 Delete a Existing Record data If the displaying record is erased, the record will data 2 Log a data 2...
  • Page 59 15.4.0 Data Log Mode - Data Log Mode Setting Data Log Mode Setting The following functions can be performed in the Data Log Mode Setting. Delete Logging the current interval 1) Delete the current data data setting 2) Set the logging interval for auto log 3) Enable the PC Synchronization Delete (transfer data from the ADC to PC)
  • Page 60 15.4.1 Data Log Mode - Setting Data Log Mode To Select Setting Display flash DEL? DEL? Press and hold the [mode] button for about 06 MAR 2003 06 MAR 2003 2 seconds to select the Data Log Mode [set] Setting Display (the ' ' starts flashing).
  • Page 61 15.5 Data Log Mode - PC Synchronization Transfer Data from the ADC to PC The ADC is equipped with a function to PC SYNC PC SYNC ... transfer/backup the data from the ADC to [set] START? STOP? To be able to transfer data to a PC, the accessory ADC-IR (optional extra) is if the send needed.
  • Page 62 15.6.0 Data Log Mode - Logged Record and Data To review Logged Data [reset] [reset] Erase a Dive Record [set] The adjacent diagram shows the operations for employing a review on the logged data. Check the 'To Select the Logged Record' record data data...
  • Page 63 15.6.1 Data Log Mode - To Select the Logged Record To Select the Logged Record [reset] Press the [reset] button to scroll forward to DATALOG select the target record (the logging time [reset] 06 MAR 2003 the next and date) among the logged records (from Logged 2:10.30 record 1 to the last record) following the...
  • Page 64 15.6.2 Data Log Mode - To Review the Logged Data To Review the Logged Data [set]/[reset] data Following the previous 'To Select the RXXX -0001 Logged Record' section to select the target 06 MAR 2003 [set]/ the next record. 2:10.30 Logged [reset] Data...
  • Page 65 16.0 Specifications A Current Time Mode Barometer Mode Hour, minute and second Current Barometric pressure Month, day, day of week and year Storm Alarm 12 / 24 hour format selectable User defined offset for Calibration Auto calendar from year 2003 to 2099 Graphical and numerical displays for barometric pressure for the last 24 hours Wind Speed Mode...
  • Page 66 16.1 Specifications - B Data Log Mode Race Timer Mode Log data includes logging time and date, Resolution: 1 second wind speed, barometric pressure, altitude Setting limit: 99 hours, 59 minutes, 59 and temperature. seconds Manual and Automatic Data Log Alarm sound: User define logging interval for automatic Last 10 minutes: beep once for every...
  • Page 67 16.2 Accuracy, resolution and units Wind Speed Altimeter Up to 3.0 m/s, better than +/-10% Better than +/- 3 meter provided properly Over 3.0 m/s, better than +/-5% calibrated. Resolution: 0.1 m/s Resolution: 1 meter Units: m/s, km/h, mph, knots, ft/s Units: meter, feet Temperature Time...
  • Page 68: Warranty

    Send a copy of your proof of purchase, the RA#, a short description of the problem Would you like to receive a Brunton Catalog? ( )Yes ( )No and the product to Brunton at the following address. Brunton suggests insuring the product in case of damage or loss in shipment.