  • Page 1 06MAR 12:38.28 88.2% 28.0 User Manual...
  • Page 2: General Guide

    1.0 General Guide Thank you for purchasing your new ADC. We recommend reading this manual, and practicing the operations before using your ADC in the field. The ADC is designed to provide you with information essential to your needs. Data such as temperature, wind speed, barometric pressure, altitude and humidity are features specific to four different ADC models: Wind,...
  • Page 3: Care And Maintenance

    2.0 Care and Maintenance Prevent getting dirt in the ADC propeller. It could clog the mechanism. Avoid exposing this product to extreme heat or extreme cold for an unreasonable amount of time. Avoid severe impacts to the ADC. Store the ADC in a dry place when it is not in use.
  • Page 4: Part Description

    3.0 Part description 1st row 06MAR 2nd row 12:38.28 3rd row 88.2% 28.0 4nd row Display Infrared Port (send data from this product to PC via this port) 06MAR 12:38.28 88.2% 28.0 [set] Detachable Belt Clip North Orientation blade (RED) Propeller Propeller blades...
  • Page 5: Button Operation Summary

    4.0 Button Operation Summary 1 [mode] [set] Note: T h e b u t t o n o p e r a t i o n s a r e summarized in the following paragraphs, for detail operating instructions, please continue reading.
  • Page 6 4.1 Button Operation Summary 2 [reset] Note: T h e b u t t o n o p e r a t i o n s a r e summarized in the following paragraphs, for detail operating instructions, please continue reading.
  • Page 7 5.0 Major Functional Modes BARO TEMP [mode] 1001.3 28.3 18.2 13.2 Barometer Mode Temperature Mode [mode] ALTITUDE m [mode] Altitude Mode Sensor Function WIND [mode] [mode] 21.3 18.3 Wind Mode Current Time Mode [mode] DATALOG 06 MAR 2003 2:10.30 r001-0023 Data Log Mode Major Functional Modes [set]...
  • Page 8: Current Time Mode

    Current Time Mode - Weather Forecast Date 06MAR Symbol Current Day of week 12:38.28 Time 88.2% 28.0 Current Temperature Weather Forecast Display 5 Seconds Mode ALTITUDE: Indicator Current 12:38.28 Altitude 88.2% 28.0 Altitude Display 5 Seconds 5 Seconds Mode BAROMETER: Indicator 1001.3h Pa Current...
  • Page 9: Setting The Current Time Mode

    Current Time Mode - 06MAR reset Second to zero 12:38.28 88.2% 28.0 '12' changes to '24'; '24' changes to '12'. [set] Current Time Mode or [reset] hold hold [mode] [mode] [mode] 12/24 [reset] scroll through [mode] the settings by increment hour hold [reset] scroll...
  • Page 10 Current Time Mode - Weather Forecast Symbols Sunny Partial Cloudy Rainy Stormy Cloudy 06MAR 12:38.28 88.2% 28.0 Weather Forecast Display Current Time Mode Note: ! When the ADC has been reset or the battery has been replaced, partial cloudy symbol will be displayed.
  • Page 11: Daily Alarm Mode

    7.0 Daily Alarm Mode - Mode indicator DAILY ALARM Alarm ON/OFF 12:00 Status Alarm time Alarm ON Display Alarm ON Indicator [set] DAILY ALARM -- : -- Alarm OFF Display Daily Alarm Mode Daily Alarm Display Daily Alarm Display In Daily Alarm Mode, the display will show the following: 1) The mode indicator ' on the 1st row of the display.
  • Page 12 7.1 Daily Alarm Mode - DAILY ALARM scroll the setting by increment of 1 12:00 [reset] Daily Alarm Mode [mode] hold hold [mode] [mode] Minute [mode] Daily Alarm Mode Setting Sequence [set] scroll the setting by decrement of 1 Setting the Daily Alarm Mode To Select the Setting Display Setting the Daily Alarm Time, press and hold the [mode] button for about 2 seconds...
  • Page 13: Chronograph Mode

    8.0 Chronograph Mode - Mode Indicator CHRONO Chronograph GRAPH Time (second) Chronograph 0:00.00 Time (hour) Chronograph Time Chronograph Chronograph Mode (1/100 Second) Time (minute) (Zero Display) 1. Elapsed time [set] 2. Accumulative elapsed time [set] [set] [set] 3. Lap time [set] [reset] [reset]...
  • Page 14: Using The Chronograph

    8.1 Chronograph Mode - Lap Time (the chronograph is counting in the background) Lap No. 10 seconds CHRONO [set] GRAPH 0:00.00 counting Chronograph Mode ('Zero' Display) Elapsed Time (the chronograph is stop counting) [reset] Note: This diagram illustrates the general flow among different functional displays only, and may NOT conform to fact in all instances.
  • Page 15 8.2 Chronograph Mode - Select the lap time by Select the lap time by backward scrolling backward scrolling (fast scrolling) (1 lap per step) hold [set] CHRONO CHRONO hold STOP [mode] RECALL 0:00.00 0:02.02 Stop Counting Display Lap Time Recall Display (Total Time) hold [reset] Select the lap time by...
  • Page 16 9.0 Race Timer Mode - Mode RACE TIMER Indicator 0:10.00 Target Time (Hour, minute, second) Race Timer Mode 1. Single-phase down [set] beep counting 2. Multi-phases down [set] [set] [set] counting 3. Reset to [set] [set] [reset] preset target time time Single/multi-down Counting &...
  • Page 17 9.1 Race Timer Mode - RACE TIMER scroll through scroll the the settings by setting by 0:10.00 increment of 1 increment [reset] Race Timer Mode hold [mode] hold [mode] [mode] Second [mode] Race Timer Mode Setting Sequence [set] scroll through scroll the the settings by setting by...
  • Page 18: Using The Race Timer

    9.2 Race Timer Mode - RACE TIMER beeps 0:10.00 stop counting Stop-Counting Display set the target time to 30 minute RACE TIMER [set] 0:30.00 counting Stop-Counting Display [reset] stop counting Note: This diagram illustrates the general flow among different functional displays only, and may NOT conform to fact in all instances.
  • Page 19 10.0 Sensor Functions Mode - BARO WIND Km/H 1001.3 21.3 18.3 Barometer Mode Wind Mode ALTITUDE m Altitude Mode Sensor Functional Mode hold [set] 2 beeps ambient Record no. & Data no temperature Logging time & date current altitude at the wind speed current location ambient barometric...
  • Page 20 11.0 Wind Speed Mode - the propeller blades are entirely exposed to air Propeller Closed Propeller Opened wind wind display Point the Propeller towards the wind direction Before Using the Wind Speed Mode How Wind Speed is Measured The ADC is equipped with a propeller that is similar to a traditional aerovane.
  • Page 21 11.1 Wind Speed Mode - Current, Max Beaufort and Average Scale Wind Speed Wind Wind Speed Speed Display Lock Alarm Manual Time Span Data Log Setting Wind Speed Mode Functions Wind Speed Mode Function Wind Speed Mode Functions ! This ADC has the following wind speed functions: 1) The Beaufort Scale: The longest and most widely used set of criteria to...
  • Page 22 11.2 Wind Speed Mode - Mode Indicator WIND Beaufort Scale 21.3 (by average wind speed) 18.3 Maximum Wind Speed Wind Speed Mode [reset] Km/h [reset] [reset] [reset] Knots Wind Speed Unit Selection Sequence Wind Speed Display Wind Speed Display In Wind Speed Mode, the display will show Wind Speed Unit the following:...
  • Page 23 11.3 Wind Speed Mode - WIND Beaufort Scale 21.3 (by average wind speed) 18.3 Wind Speed Mode Beaufort Scale (calculated by average wind speed) force force force no. 1 no. 5 no. 10 Example A: Number 5 of Beaufort Scale Beaufort Scale (calculated by average wind speed) force...
  • Page 24 11.4 Wind Speed Mode - Beaufort Scale Table...
  • Page 25 11.5 Wind Speed Mode - WIND mph 21.3 18.3 Wind Speed Mode [set] 5 seconds WIND mph lock 21.3 indicator 18.3 display flashing keep still Wind Speed Mode (Display Locked) hold [mode] (confirm Note: reset) This diagram illustrates the general flow among d i f f e r e n t f u n c t i o n a l displays only, and may NOT conform to fact in...
  • Page 26 11.6 Wind Speed Mode - Wind Speed Alarm Range preset wind speed level Below Alarm Range The Wind Speed Alarm Range Wind Speed Alarm Wind Speed Alarm The ADC is equipped with a wind speed 'beep' for 5 alarm. seconds That alarm alerts user when the current (every 2 minutes)
  • Page 27 11.7 Wind Speed Mode - Wind Speed Alarm and hold Time Span Setting Sequence [mode] WIND mph Wind Speed 21.3 Alarm 18.3 hold [mode] Wind Speed Mode Wind Speed Alarm Setting Alarm OFF Alarm ON WIND mph WIND mph [set] - - - - 50.3 18.3...
  • Page 28 11.8 Wind Speed Mode - North East North Target object pole red-colored blade Using the Propeller as a Mechanical Compass Using the Propeller as a Mechanical Compass Propeller as a Mechanical Compass The ADC measures ambient temperature, wind speed, and it also tells compass directions.
  • Page 29: Temperature Functions

    12.0 Temperature - Temperature Functions Current, Minimum Current Wind Chill Temperature Temperature Wind Chill Temperature Temperature History Graph Alarm Manual Temperature Data Log Calibration Temperature Mode Functions Temperature Mode Functions ! The ADC has the following temperature functions: 1) The Current Temperature: The Current Temperature readings.
  • Page 30: Temperature Display

    12.1 Temperature - Temperature Display Mode Indicator TEMP 28.3 18.2 13.2 Current Wind Chill Temperature Temperature Mode [reset] Temperature Display In Temperature Mode, the display will show Temperature the following: Unit TEMP 1) The ' Current unit appear on the 1st row of the display. Temperature 2) The Current Temperature appears on the Minimum Wind Chill...
  • Page 31: Temperature Mode

    12.2 Temperature Mode- Current Wind Temperature Temperature Case Conditions NO wind 15F/ -9.4C 15F/ -9.4C wind speed 15F/ -9.4C -10F/ -23.3C at 50 mph/ 80.5 km/h NO wind -10F/ -23.3C -10F/ -23.3C Wind Chill Temperature Effects Wind Chill Temperature What is Wind Chill Temperature Wind chill is a temperature factor that Wind Chill combines air temperature and the effect of...
  • Page 32 12.3 Temperature Mode - TEMP 28.3 18.2 13.2 Temperature Mode RESET MIN W.CHILL? 18.2 Maximum Wind Speed Reset Display - NO hold [mode] (confirm Note: reset) RESET MIN This diagram illustrates W.CHILL? the general flow among d i f f e r e n t f u n c t i o n a l displays only, and may 18.2 not conform to fact in...
  • Page 33 12.4 Temperature Mode - TEMP 28.3 18.2 13.2 Temperature Mode [mode] [set] -24 hour the temperature of the selected 28.3 record (numeric) 18.2 1-00 current wind chill Temperature History Graph Display hold [reset] [reset] Select the record by forward scrolling (1 hour per step) Select the lap time by Select the lap time by...
  • Page 34 12.5 Temperature Mode - Wind Chill Temperature High Temperature Range preset wind chill temperature Low Temperature Range level The Wind Chill Temperature Alarm Wind Chill Temperature Alarm Wind Chill Temperature Alarm The ADC is equipped with a wind chill temperature alarm. That alarm alerts user when the current wind chill temperature is equal to or lower than the preset wind chill temperature level.
  • Page 35 12.6 Temperature Mode - Wind Chill Temperature Alarm and hold Temperature Calibration [mode] Setting Sequence TEMP Wind Chill Temperature 28.3 Alarm 18.2 13.2 hold [mode] Temperature Mode Wind Chill Temperature Alarm Setting Alarm ON Alarm OFF W.CHILL W.CHILL [set] - - - - -10.0 18.3 18.3...
  • Page 36: Calibrating The Temperature

    12.7 Temperature Mode - TEMP OFFSET 18.3 Temperature Calibration Display [mode] hold [reset] TEMP OFFSET wind chill temperature 18.3 Calibration Setting Display hold [reset] [reset] Select the setting by forward scrolling Select the setting by Select the setting by forward scrolling backward scrolling (fast scrolling) (fast scrolling)
  • Page 37: Barometer Mode

    13.0 Barometer Mode - 24 Hour Pressure Stormy Alarm History Graph Pressure Data Log Calibration Barometer Mode Functions Barometer Mode Function Barometer Mode Functions ! The ADC has the following barometric pressure functions: 1) The 24-Hour Pressure History Graph: The Barometric Pressure Memory for the last 24 hours.
  • Page 38: Barometer Display

    13.1 Barometer Mode - Mode Indicator BARO 1001.3 Barometer Mode [reset] [reset] [reset] inHg Barometric Pressure Unit Selection Sequence Barometer Display Barometer Display Pressure In Barometer Mode, the display will show the Unit following: Current 1) The mode indicator ' Barometric the barometric pressure unit appear on the Pressure...
  • Page 39 13.2 Barometer Mode - BARO 1001.3 Barometer Mode [mode] [set] -24 hour the pressure of the selected 1023.2 record (numeric) 1-00 Pressure History Graph Display hold [reset] [reset] Select the record by forward scrolling from -24 hour to current (1 hour per step) Select the lap time by Select the lap time by forward scrolling...
  • Page 40 13.3 Barometer Mode - Weather Forecast Symbols Stormy Storm 06MAR alarm on 12:38.28 88.2% 28.0 Weather Forecast Display About Storm Alarm About Stormy Alarm The alarm gives beep alert when the ADC predicts the upcoming weather as stormy. Then, in the Current time - Weather Forecast Display, the 'stormy' weather forecast symbol will appear.
  • Page 41 13.4 Barometer Mode - hold Storm Alarm and Pressure [mode] Calibration Setting Sequence BARO Stormy 1001.3 Alarm Barometer Mode hold hold [mode] [mode] (Alarm OFF) (Alarm ON) BARO BARO [set] STORM STORM 1001.3 1001.3 current Alarm ON Alarm OFF barometric pressure Storm Alarm Setting Setting the Storm Alarm...
  • Page 42 13.5 Barometer Mode - BARO OFFSET 1001.3 Pressure Calibration Display [mode] hold [reset] BARO OFFSET 1001.3 Calibration Setting Display hold [reset] [reset] hold [set] Select the setting by forward scrolling Select the setting by Select the setting by forward scrolling backward scrolling (fast scrolling) (fast scrolling)
  • Page 43: Altimeter Mode

    14.0 Altimeter Mode - Accumulative Current, Min & Ascend & Descend Max Altitude Altitude Calibration manual Data Log Altimeter Mode Functions Altimeter Mode Functions Altimeter Mode Functions This mode has the following functions: 1) The different altitude readings: Current, Minimum and Maximum Altitude. Altitude 2) The Accumulative Ascend and Descent Altitude: The sums of the ascending/...
  • Page 44: Altitude Mode

    14.1 Altitude Mode - ALTITUDE m SKI RUN: 99 2237 2418 Ski-Run Display [set] Mode Indicator ALTITUDE m Altitude Max-Min Display Altimeter Mode Functional Displays unctional Displays Ski Run Altimeter Mode includes three different number functional displays, they are the Ski-Run Display, Max-Min Display and Air-Density Accumulated Display.
  • Page 45 14.2 Altimeter Mode - [reset] Select among the Altitude Units Altimeter Mode To Change Altitude Units To Change Altitude Units The ADC can display altitude in the following units: 1) Meter (m) 2) Feet (ft). In any of the functional displays (Ski-Run, Max-Min and Air-Density Display), press the [reset] button to select the altitude unit following the adjacent diagram.
  • Page 46 14.3.0 Altimeter Mode - Mode Indicator ALTITUDE m SKI RUN: 99 Current Altitude 2237 2418 Accumulated Ascent Ski Run Display Altimeter Mode record ski-run count altitude (m) (counter +1) Starting point point Ski-Run 1 Altitude Ski-Run Display Ski-Run Display Altitude The ADC is equipped with functions to register unit ski runs.
  • Page 47 14.3.1 Altimeter Mode - Ski-Run Function ON-OFF Setting Function OFF Function ON SKI RUN ON? SKI RUN ON? [set] hold [mode] hold [mode] (Ski-Run (Ski-Run Function ON) Function OFF) ALTITUDE m hold SKI RUN: 99 [reset] Ski-Run Function ON-OFF 2237 2418 Ski Run Display Ski-Run...
  • Page 48 14.3.2 Altimeter Mode - SKIRUN RESET? ALTITUDE m SKI RUN: 99 Activated 2237 2418 Ski-Run Counter Reset Setting Ski Run Display hold hold [reset] [mode] Ski-Run Function ON-OFF [mode] DESCEND Ski-Run RESET? Descend Reset 2237 2418 Ski-Run Counter, Ascend and Descend Reset Setting Sequence Activated [set]...
  • Page 49 14.4.0 Altimeter Mode - Highest point altitude (m) Starting Lowest Starting point point point point (reset the max Trail 1 & min altitude) This Product will display Trail 1 Trail 2 at point A Maximum 500 m 550 m Altitude Minimum 150 m 200 m...
  • Page 50 14.4.1 Altimeter Mode - ALTITUDE m hold Max-Min Display [mode] (abort reset) flashing RESET MAX [mode] ALT ? flashing Maximum Altitude Minimum Altitude Reset Display - NO Reset Display - NO [set] flashing RESET MAX ALT ? [mode] flashing Maximum Altitude Minimum Altitude Reset Display - YES Reset Display - YES...
  • Page 51: Altitude Alarm

    14.5 Altimeter Mode - Altitude Undesirable Range preset altitude level Desirable Range The Altitude Alarm Altitude Alarm Altitude Alarm The ADC is equipped with an altitude alarm. That alarm alerts user when the current altitude is equal to or higher than the preset 'beep' altitude level.
  • Page 52 14.6.0 Altimeter Mode - hold [mode] ALTITUDE m Altitude Alarm Setting hold [mode] Altitmeter Mode Altimeter Mode Setting Sequence Altitude Mode Setting Altimeter Mode Setting The following functions can be performed in [mode] the Altimeter Setting Mode. Altitude 1) Altitude Alarm Settings, Calibration a) ON or OFF Display...
  • Page 53 14.6.1 Altimeter Mode - Altitude Alarm Setting Alarm OFF ALTITUDE m ALTITUDE m W.CHILL [set] - - - - 18.3 hold [reset] [reset] scroll the setting faster Setting the Altitude Alarm To Set the Altitude Alarm Following the previous 'Altimeter Mode Alarm ON Setting Sequence' to select the Altitude Alarm Setting Display.
  • Page 54: Calibrating The Altitude

    14.6.2 Altimeter Mode - ALTITUDE m ADJUST Altitude Calibration Display [mode] hold [reset] ALTITUDE m ADJUST Calibration Setting Display hold [reset] [reset] hold [set] Select the setting by forward scrolling Select the setting by Select the setting by forward scrolling backward scrolling (fast scrolling) (fast scrolling)
  • Page 55 15.0 Data Log Mode - data data data Free Memory Display Record ambient Record no. & Data no temperature Logging time & date current altitude at the wind speed current location ambient barometric relative pressure humidity The Elements of a Data Record and Data MEMORY FULL...
  • Page 56: Data Log Mode

    15.1 Data Log Mode - DATALOG the date that this record 06 MAR 2003 was logged 2:10.30 the record r001-0023 no. of this record Data Log Display 3 seconds FREE: 1350 06 MAR 2003 2:10.30 r001-0023 Free Memory Display DATALOG NO RECORD -- : -- -- r000-0000...
  • Page 57 15.2 Data Log Mode - DATALOG DATALOG 06 MAR 2003 06 MAR 2003 hold [set] 2:10.30 r001-0023 Data Log Display Data Log Display (Auto-Log OFF) (Auto-Log ON) Example 1: data 1 data 2 data 3 logged logged logged Record 1 (set 10 seconds hold [set] beep...
  • Page 58 15.3 Data Log Mode - Data and Record Administration data 1 data Log a data 2 new data Record Acquire a New Data Record 1 Record 2 Record 2 Delete a Record 3 record Delete a Record Log a New Data When a new data is logged, this data will become the last one of the data list.
  • Page 59 15.4.0 Data Log Mode - Delete Logging the current interval data setting Delete all Record Synchronization & Data Data Log Mode Setting Data Log Mode Setting Data Log Mode Setting The following functions can be performed in the Data Log Mode Setting. 1) Delete the current data 2) Set the logging interval for auto log 3) Enable the PC Synchronization...
  • Page 60 15.4.1 Data Log Mode - DEL? 06 MAR 2003 2:10.30 DATALOG r001-0023 06 MAR 2003 2:10.30 Activated r001-0023 Delete the Current Data Data Log Display hold hold [mode] Delete the [mode] record that is displaying [mode] DEL ALL ? Delete all record and data Data Log Mode...
  • Page 61 15.5 Data Log Mode - PC SYNC PC SYNC ... [set] START? STOP? if the send Ready Sending completed PC Synchronization Infrared Port Pointing this port towards the ADC-IR connected to a PC PC Synchronization Transfer Data from the ADC to PC The ADC is equipped with a function to transfer/backup the data from the ADC to To be able to transfer data to a PC, the...
  • Page 62 15.6.0 Data Log Mode - [reset] Erase a Dive Record [set] data data data hold [mode] Record [set] [mode] ambient Record no. & Data no temperature Logging time & date current altitude at the wind speed current location ambient barometric relative pressure humidity...
  • Page 63 15.6.1 Data Log Mode - DATALOG [reset] 06 MAR 2003 2:10.30 r001-0023 record 0023 Data Log Display (Record 1) this record consist of 23 data [reset] Record Selection Sequence [set] data RXXX -0001 06 MAR 2003 [set]/ 2:10.30 [reset] 88.2% 28.0 Data Log Display (Data 1)
  • Page 64 15.6.2 Data Log Mode - data RXXX -0001 06 MAR 2003 [set]/ 2:10.30 [reset] 88.2% 28.0 Data Log Display (Data 1) [set]/[reset] Data Selection Sequence [mode] wind speed R001 -0001 06 MAR 2003 [mode] logging date & 2:10.30 time 88.2% 28.0 temperature Date &...
  • Page 65 16.0 Specifications A Current Time Mode Hour, minute and second Month, day, day of week and year 12 / 24 hour format selectable Auto calendar from year 2003 to 2099 Wind Speed Mode Current, Average and Maximum Wind Speed Beaufort Scale for Average Wind Speed 5 Wind Speed Unit Selection (Km/h, mph, feet/s, m/s, and Knots).
  • Page 66 16.1 Specifications - B Data Log Mode Log data includes logging time and date, wind speed, barometric pressure, altitude and temperature. Manual and Automatic Data Log User define logging interval for automatic data log Data transfer from the ADC to PC via the infrared synchronization, ADC-IR unit is required.
  • Page 67 16.2 Accuracy, resolution and units Wind Speed Up to 3.0 m/s, better than +/-10% Over 3.0 m/s, better than +/-5% Resolution: 0.1 m/s Units: m/s, km/h, mph, knots, ft/s Temperature Better than +/-1 Celsius degree (offset calibration possible) Resolution: 0.1 degree Units: Celsius, Fahrenheit Barometer Better than +/-1.5mb (700 ~ 1100 mb) (offset...
  • Page 68: Warranty

    City: _______________________ State: ___________ Zip: ________________ Phone: ___________________________Email__________________________ Date Purchased: ______________________ Amount Paid: _________________________ Would you like to receive a Brunton Catalog? ( )Yes ( )No Please let us know where you purchased your ADC Store Name: ________________________ City: _______________________ State: ___________ Zip: ____________...