Auto Recovery

Hunter's Auto Recovery feature meets the ENERGY STAR
allowing the heating or cooling system to recover gradually from an energy-saving setpoint
temperature to a comfort setpoint temperature.
Auto Recovery calculates how early to turn your system back On, so that the room temperature is
already comfortable by the start of the comfort temperature program period. Auto Recovery
works in both Heat and Cool modes.
When the thermostat is in Auto Recovery mode, the display
will alternate "RECO" with time, and the program indicator
will flash.
Auto Recovery can be disabled by sliding the Recovery
switch on the circuit board.
Auto Recovery will not operate if Permanent hold or Tempo-
rary hold is in operation.
Auto Recovery can be canceled manually if
HOLD / RETURN is pressed during the recovery process.
Auto Recovery will be canceled and change to Temporary
Manual Override mode if the setpoint is adjusted during the
recovery process.

Error Mode

If the thermostat is unable to control your system due to an
unexpected battery problem, the thermostat will enter Error
Mode. In this condition, the thermostat flashes "Err" on the
LCD display, and shuts off your system. To correct this problem,
replace the batteries with 2 new AA alkaline batteries, even if
you have recently replaced them. Next, use a paper clip to
press the RESET button next to the keypad. You will need to
reprogram your thermostat and confirm normal operation.
If Error Mode returns, please call Hunter Technical support at 1-888-830-1326 for further
information.

Auto Cut Off

Your thermostat will automatically cut-off in Heat mode if the room temperature rises
above 95˚F (35˚C). It will cut-off in Cool mode if the room temperature drops below 40˚F
(4˚C).
Note that if your system has malfunctioned and no longer responds to thermostat controls, the
Auto Cut-Off will have no effect.
®
guidelines for energy efficiency by
2
HEAT TEMP

TROUBLESHOOTING

Problem
Solution
No Display
1. Check battery connections and batteries.
2. Press RESET button with a small pin and hold in
Entire Display Dims
1. Replace Batteries
Program Does Not Change
1. Check that the time is set properly to "AM"
at your Desired Setting
2. Check that the thermostat is not in Permanent
3. Check for the correct day setting.
Auto Fan Does Not
1. Move HG/HE selector to correct position.
Turn On Properly
Heating or Cooling Does
1. Check that the function switch is in the correct
Not Go On or Off
2. There may be as much as 4-minute delay before
3. Check your circuit breakers and switches to ensure
4. Replace batteries.
5. Make sure your furnace blower door is
6. If your non-heat pump system only uses 4-wires, be
7. Check the position of the System Selector switch:
Erratic Display
1. Press the reset button once with a small pin and hold
If unit continues to operate
1. Replace unit.
in the Off position
Thermostat permanently
1. Replace unit.
reads "HI", "LO", or "ERR"
If you experience any other problems, call 1-888-830-1326 from 8 AM to 5 PM Central Time
for technical assistance.
© 2003 Hunter Fan Company
41640-01 07/01/03
for two seconds.
or "PM".
HOLD mode.
position ("HEAT" or "COOL").
the system turns On – wait and check. (Compressor
protection delay.)
there is power to the system.
closed properly.
sure the jumper wire is installed between the RC and
RH terminals.
Standard or Heat Pump.
for two seconds. Then reprogram.
Hunter Fan Company
2500 FRISCO AVENUE
®
MEMPHIS, TN 38114
7