Outdoor Fan Motor Control - Toshiba RAS-B10SKVP-E Service Manual

Split type air conditioner
Hide thumbs Also See for RAS-B10SKVP-E:
Table of Contents

Advertisement

Item
3. Outdoor fan
The blowing air volume at the outdoor unit side is controlled.
motor control
Receiving the operation command from the controller of
indoor unit, the controller of outdoor unit controls fan speed.
* For the fan motor, a DC motor with non-stage variable
speed system is used. However, it is limited to 16 stages
for reasons of controlling.
Air conditioner ON
(Remote controller)
Indoor unit controller
1) Outdoor unit
operation command
(Outdoor fan control)
2) Fan speed
when the motor stopped.
Fan motor ON
3) Fan lock
4) Motor operates as shown in the table below.
In cooling operation
Compressor speed (rps)
To > 38°C
To > 28°C
To > 15°C
To
To > 5.5°C
To > 0°C
To > 38°C
During
SLEEP MODE To < 38°C
When To is abnormal
10SAVP-E
T ap
10SAVP-ND
f 1
200
f 2
300
f 3
390
f 4
450
f 5
500
f 6
500
f 7
600
f 8
600
Operation flow and applicable data, etc.
YES
400
fan motor continues.
NO
YES
Air conditioner
NO
~ 13.8
~ 31.7
MIN MAX MIN MAX MIN MAX
f 2
f 3
f C
f D
f 2
f 3
f B
f C
f 2
f 3
f 8
f 9
f 2
f 3
f 6
f 7
f 1
f 2
f 4
f 5
f 2
f 3
f B
f C
f 2
f 3
f 2
f 3
f D
f F
f D
f F
Outdoor fan speed (rpm)
13SAVP-E
16SAVP-E
13SAVP-ND
16SAVP-ND
200
200
300
300
390
390
450
450
500
500
500
500
600
650
600
650
OFF status of
Alarm
OFF
display
32.3 ~ MAX
Compressor speed (rps)
f E
f F
To
f E
f F
f A
f B
f 8
f 9
During
f 6
f 7
SLEEP
f C
f D
MODE
f B
f C
f D
f F
When To is abnormal
10SAVP-E
T ap
10SAVP-ND
f 9
700
f A
700
f B
700
f C
700
f D
750
f E
750
f F
750
– 33 –
Description
1) The operation command sent
from the remote controller is
processed by the indoor unit
controller and transferred to the
controller of the outdoor unit.
2) When strong wind blows at
outdoor side, the operation of air
conditioner continues with the fan
motor stopped.
3) Whether the fan is locked or not
is detected, and the operation of
air conditioner stops and an
alarm is displayed if the fan is
locked.
4) According to each operation
mode, by the conditions of
outdoor temperature (To) and
compressor revolution, the speed
of the outdoor fan shown in the
table is selected.
In Heating operation
~16.8 ~47.9 48.5 ~ MAX
To > 15°C
f 3
f 8
To < 15°C
f 3
f 9
To < 5.5°C
f 8
f A
To < –5.0°C
f B
f C
To > 15°C
f 3
f 3
To < 15°C
f 3
f 3
To < 5.5°C
f 5
f 9
To < –5.5°C
f 7
f A
f A
f B
13SAVP-E
16SAVP-E
13SAVP-ND
16SAVP-ND
700
700
700
700
840
840
840
f 9
f A
f D
f D
f 6
f 8
f 9
f B
f D
750
750
750
750
920
920
920

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents