Connecting the Cables to the Outdoor Unit
UCC2400C
UCC2800C
UCC4400C
48
E-
Two electric cables must be connected to the outdoor unit.
The connection cord connecting the indoor unit to the outdoor unit
The power cable connecting the auxiliary circuit breaker to the
outdoor unit
1
Remove the terminal board cover on the side of the outdoor unit.
2
Connect the connection cord(1, 2, 3,
terminals through the conduit hole as shown in the diagram.
3
Connect the power cable to the auxiliary circuit breaker.
An all pole disconnection from the power supply must be incorporated in the
1
fixed wiring(≥3mm/ ").
8
4
Replace the terminal board cover, carefully tightening the screw.
Conduit hole
Outdoor Unit
Auxiliary circuit
breaker
Wiring Diagram
Wiring Diagram
C
A
U
T
I
O
N
C
A
U
T
I
O
N
Keep the power cable and the connection cord in a steel
pipe to protect them against liquids, outside impacts
and so on.
) and power cable(L1, L2) to
Indoor Unit
Communication
Power
Power Cable
Indoor Unit
1
2
3
Power
Communication
EARTH
Outdoor Unit
1
2
3
L1 L2
Power Cable
Auxiliary circuit
breaker
EARTH