Connecting the Cables to the Outdoor Unit
One electric cable must be connected to the outdoor unit:
◆ The assembly cable connecting the indoor unit to the outdoor unit
1
Remove the terminal board cover on the side of the outdoor unit.
2
Connect the assembly cable to terminals as shown in the figure.
➢
Each wire is labelled with the corresponding terminal number.
➢
Each wire from the terminal number of the indoor unit.
Shall be comected with the same terminal number of its outdoor unit.
3
Connect the earth wires to the earth terminals.
➢ Refer to the page 15 for further details on how to check that earthing
is correct.
4
Replace the terminal board cover, carefully tightening the screw.
I
O
NSTALLING THE
UTDOOR
✴✴07/09✴✴
AS12AA(B)MCF
Indoor
E
(A) 1
L1 L2
unit
1
L1
L2
E
E
1
L1
L2
Outdoor
unit
L1 L2 1
2
3
L1
L2
E
Ground
terminal
Circuit Breaker(Main Power)
U
NIT
13
E-