Heatilator GDST5244I Owner's Manual page 16

See-through direct vent gas appliance
Hide thumbs Also See for GDST5244I:
Table of Contents

Advertisement

Top Vent--Horizontal Termina6tion--Two or three Elbows
You may use a maximum of three 90° elbows (or six 45° elbows) in any vent confi guration, Some may be installed
horizontally.
Figure 5.6 Two or Three Elbows, some Horizontal
16
Note: Subtract 3 ft (914 mm) from the total horizontal
measurement for each 90° elbow installed horizontally.
Subtract 1-1/2 ft (457 mm) from the total horizontal
measurement for each 45° elbow installed horizontally.
V
min.
V
max.
1
1
18 in./457 mm
x
24 in./610 mm
x
x
25 ft/7.62 m
H
3
Installed
Horizontally
H
H
2
2
Heatilator • GDST5244I • 4045-127 Rev Q • 02/07
Table 5.3
H
+H
max.
H
+H
1
2
1
18 ft/5.49 m
18 ft/5.49 m
25 ft/7.62 m
25 ft/7.62 m
25 ft/7.62 m
25 ft/7.62 m
+H
max.
2
3
Installed
Vertically
V
H
1
1