2. Top Vent - Vertical Termination
V
= 40 ft. Max. (12.4 m)
1
V
= 3 ft. Min. (914mm)
1
NOTE: If installing a vertical vent/
termination off the top of the appli-
ance, the optional vertical termina-
tion baffle should be used.
No Elbow
Figure 5.6
Heat & Glo • 6000GLX-IPI-S/-R, 6000GLX-IPILP-S/-R • 2101-900 Rev. H • 4/07
Flue Restrictor Instructions
1. Remove the top piece of refractory, if already installed
(see Figure 5.7).
TOP
REFRAcTORY
Figure 5.7
2. Break the Flue Restrictor into two pieces. Do this by
bending the part back and forth until it breaks (see
Figure 5.8).
BREAK
hERE
Figure 5.8
Flue Restrictor
FLuE
RESTRIcTOR
15