Led Fault Code Indications; Limited Warranty Information - PRO Charging System i2412 Safety, Installation And Operating Instructions

Pro charging system battery chargers - safety, installation and operating instructions
Table of Contents

Advertisement

This is the normal operating procedure for the system. It indicates that a reanalysis of the battery status was initiated and
after a series of steps the green LED will illuminate.
LIGHT EMITTING DIODES (LED) FAULT CODE INDICATIONS
The microprocessor is constantly monitoring the charger circuitry and will both detect and display blinking LED indications if a
fault is detected. The battery type LED will be OFF during a fault code condition.
30% RED LED BLINKING .....................................................NO BATTERY DETECTED
This indication occurs whenever the charger circuitry cannot detect a battery. The charger circuitry will not allow charge
current to flow under this condition. With the AC power supply cord unplugged, check the connection to the batteries for
proper polarity (black wire to negative or -). Also check for corrosion free secure connections to the battery. Please call
technical support for further assistance (800.742.2740).
30 & 60% RED BLINKING LEDS ............FORMING STAGE TIMEOUT SHUTDOWN
This indication occurs if the battery voltage has not risen above 1.75 volts per cell within the first 3 hours of charging. This
indicates that a possible battery problem exists and that the charge cycle has been terminated at this point. Please call
technical support for further assistance (800.742.2740).
30, 60 & 90% RED BLINKING LEDS ............................OVERALL TIMER SHUTDOWN
This indication occurs if the charger has not completed the charge cycle within the allowable factory set time period. This
indicates that a possible battery problem exists and that the charge cycle has been terminated at this point. Please call
technical support for further assistance (800.742-2740).
30, 60, 90% RED and 100% GREEN BLINKING LEDS.......................INTERNAL OVERTEMP SHUTDOWN
This indication occurs if the charger circuitry has detected operating temperatures inside the charger enclosure that are
above factory specified levels. This could indicate that a possible charger problem exists and that the charge cycle has been
terminated. Please call technical support for further assistance (800.742.2740).
Note: Disconnecting and reconnecting the AC power supply cord will reset the charger.
LIMITED WARRANTY
Pro Charging Systems, LLC (PCS) makes this Limited Warranty only to the original retail purchaser.
PCS warrants this battery charger for three years from the date of retail purchase against defective materials and/or
workmanship. If such defects should occur, this unit will either be repaired or replaced at the discretion of the manufacturer.
It is the responsibility of the original purchaser to return the charger along with proof of purchase, transportation, and/or any
mailing or handling charges prepaid to the manufacturer or its authorized representative.
This limited warranty is void if the product is misused, improperly maintained, handled carelessly or incorrectly operated.
Additionally, this warranty is void if the charger is disassembled, the charger's charge cables are cut, the power cord is cut
off, the charger is altered without authorization from PCS, the serial number is removed, or repair is attempted by anyone
other than an authorized representative.
PCS makes no other warranty other than this limited warranty and expressly excludes any implied warranty, including
warranty for any incidental or consequential damages.
This is the only expressed limited three year warranty authorized by PCS and does not authorize anyone to assume or make
any other obligation towards the product other than this three year Limited Warranty. Some states do not allow limitation of
incidental or consequential damages.