WI 9 ME WI 14 ME Montage- und Gebrauchsanweisung Installation and Operating Instructions Instructions d’installation et d’utilisation Wasser/Wasser- Water-to-Water Pompe à chaleur Wärmepumpe für Heat Pump for eau-eau pour Innenaufstellung Indoor Installation installation intérieure Bestell-Nr. / Order no. / N de commande : 452232.66.17...
Please Read 1.3 Energy-Efficient Use of the Immediately Heat Pump By operating this heat pump you are helping to protect our envi- ronment. Both the heating system and the heat source must be 1.1 Important Information properly designed and dimensioned to ensure efficient operation. It is particularly important to keep water flow temperatures as low ATTENTION! as possible.
The side panel assemblies must be removed for this purpose. Any commercially available length of pipe can be used as a carrying aid. ATTENTION! Do not use the holes in the panel assemblies for lifting the device! Evaporator Switch box Liquifier Compressor www.dimplex.de...
Set-up Installation 5.1 General Information 6.1 General Information The unit may only be installed indoors in rooms with low humidity The following connections need to be established on the heat on a level, smooth and horizontal surface. The entire base of the pump: frame should lie directly on the floor to ensure a good soundproof Flow and return flow of the well system...
13° C 18° C 11 K 19° C 25° C 12 K Any faults occurring during operation are displayed on the heat pump controller and can be corrected as described in the operat- ing manual of the heat pump controller. www.dimplex.de...
Maintenance and 8.4 Water Quality Requirements Cleaning The ground water should not contain any substances that could form deposits. The limit values for iron (< 0.2 mg/l) and manga- nese (< 0.1 mg/l) must be adhered to prevent iron ochre sedi- 8.1 Maintenance mentation in the heat pump system.
The specified values, e.g. W10 / W55, have the following meaning: Heat source temperature 10 °C and heating water flow temperature 55 °C. 2. Note that additional space is required for pipe connections, operation and maintenance. 3. See CE declaration of conformity 4. The heat circulating pump and the heat pump controller must always be ready for operation. www.dimplex.de...
3.4 Legende / Legend / Légende Drahtbrücke, muss eingelegt werden, wenn kein Wire jumper, must be inserted if no blocking con- Le cavalier à fil doit être inséré en absence de dis- Sperrschütz benötigt wird tactor is required joncteur de blocage du fournisseur d'énergie Drahtbrücke, muss bei Verwendung des 2ten Sper- Wire jumper, must be removed if the 2nd disable Cavalier à...
5 Konformitätserklärung / Declaration of Conformity / Déclaration de conformité www.dimplex.de A-XI...
Page 20
Glen Dimplex Deutschland GmbH Irrtümer und Änderungen vorbehalten. Geschäftsbereich Dimplex Subject to alterations and errors. Am Goldenen Feld 18 Sous réserve d’erreurs et modifications. D-95326 Kulmbach +49 (0) 9221 709 565 www.dimplex.de...