Eden HA2000 Installation & Operating Manual

Wirefree alarm system 20 zones

Advertisement

HA2000
HA2000Y
Wirefree Alarm System
20 Zones
Installation & Operating Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HA2000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Eden HA2000

  • Page 1 HA2000 HA2000Y Wirefree Alarm System 20 Zones Installation & Operating Manual...
  • Page 2: Introduction And Overview

      - Reliability:   All parts of the EDEN HA2000 system undergo high quality controls so as to ensure the security of your home for many years.   Each part has undergone a serious ratification by...
  • Page 3: Kit Contents

    The Alarm Sustem HA2000Y should contain the for PIR detector siren same elements as the kit HA2000 and these elements in addition: PROBLEM? Do not HESITATE to call us via our assistance hotline (at the end of the notice). Our technicians will have the pleasure to...
  • Page 4 Even if the EDEN HA2000 system allows you to manage up to 20 accessories, keep in mind that it is not necessary to protect all the rooms in your...
  • Page 5: Application Overview

    The main alarm was placed in the hall. Generally, current screen and returning to the it should be put in a central area of the house and previous screen etc. not visible from the windows. 6. “OK” Key HA2000E outdoor flash-siren warns To confirm the keyed-in data or confirm...
  • Page 6: Getting Started

    beep. “Alarm On” will be displayed on the first line of the screen indicating the system is in Away mode (this is the default mode) Step 3. Press “ 0 “ key on the keypad, the display will show. E n t e r C o d e * _ _ _ Step 4.
  • Page 7: Configuring Your System

    following items can be selected.   Walk Test Configuring your system  Gen. Settings. Devices +/- I. Entering Programming mode  Step 6. After making a selection by moving the cursor to the desired item, press “OK” to The Programming mode is for you to configure confirm the selection. The display will the system.
  • Page 8 Step 5. Follow the same steps to program and “User2” is used to regularly arm and disarm the activate User2, Cleaner and the Temp system. PIN codes respectively. The “Cleaner” code can only be used to Away < >   <...
  • Page 9: Exit Time

    s e c . Use “ ”,“ ” keys to switch between 2. Master PIN code options. Master PIN code is used for accessing the Press “OK” to confirm. programming mode and it is set to “0000” as factory default. Before you set your own Master 10 sec.
  • Page 10: Door Chime

    This is for you to decide whether to enable or “Chime Low” is set as factory default. disable the Control Panel Tamper protection. < >   < >   C . U . T a m p e r If “Chime Low” or “Chime High” is C .
  • Page 11: Add/ Delete Device

    sec. in case any fault condition persists. HA2000R Remote Controller - RC HA2000K Remote Keypad ---- KP 13. Language HA2000SOS Help Watch ---- HW Choose the language as you would like for the HA2000PB Panic button ---- PB control panel. HA2000NS Night Switch ---- NS E n g l i s h HA2000WS Water detector ---- W...
  • Page 12 The PIR detector is in zone 3, programmed for burglar Battery mode with an Instant attribute and is named “Hall”. The Remote Controller uses one “CR2032” 3V 230 mAh Lithium battery as its power source. Battery life is over 2 years in a normal Remote Controller HA2000R ...
  • Page 13 The example screen represents the Device Naming Remote Controller is installed in zone 3 Detectors can be given names and location and it is a “Personal Attack” Remote descriptions to help understand system events. Controller. The devices can be named when first installing StepC8.
  • Page 14 When the Open Contact is in Low battery condition, every time the Open Contact is activated (door opened or door closed), the 1. LED indicator LED will light. 2. Learn / Test button When the cover is opened and the tamper switch is violated, the LED will light.
  • Page 15 it will work in different modes. programmed). StepA5. After the detected Open Contact is “D” for Home Delay Open Contact confirmed, you are requested to choose When the system is in Arm mode, if a between “Burglar”, “Home Omit”, Open Contact “Home Delay”...
  • Page 16 “Burglar”, “Home Omit”& “Home flat surface or in a corner situation with a triangular Delay” device mode, but not available bracket for corner mounting. with “Entry” device mode. While “24 Provision for a tamper switch that will be activated Hour”, “Fire” device mode are assignd when the cover is detached from the base prevents to have Instant attribute by nature.
  • Page 17 If the Control Panel doesn’t receive the transmissions for the Control Panel to Supervisory signals transmitted from a certain display the status accordingly. PIR, an “Out-Of-Order” fault message will be For each installation, the battery is installed generated. in by the factory before shipment with an Insulator inserted.
  • Page 18 following Step A6 for adding the Door “P” for Personal Attack Help Watch Contact. Control Panel will give a Personal Attack StepB7. Make a selection and press “OK”. The alarm when the button is pressed for screen will change to: more than 2 seconds.
  • Page 19 Control Panel will give a Personal Attack < >   < >   alarm when the Panic Button is pressed for more than 2 seconds. “IA” Internal Alarm Detector/Water Detector “M” for Medical Button When the Internal Alarm detector is Control Panel will give a Medical alarm activated, only the Control Panel will when the Panic Button is pressed for...
  • Page 20 completed. Remote Keypad is not assigned to any mode < >   < >   Smoke Detector automatically assigned to Fire mode Device Mode by Alarms Home Instant Alarm definitions by Device Type of Device Mode Delayed Chime Accessorises Mode Mode mode Sirens (Ext, Int and Control panel) Burglar (B) √...
  • Page 21: Remove Devices

    Z o n e 0 1 Z o n e 0 2 J o h n ..H a l l ..Z o n e 0 2 P I R Z o n e 0 3 H a l l .
  • Page 22 C o n f i r m Siren A/T On, Siren A/T Off C o n f i r m O f f The Siren tamper switch can be enabled and disabled remotely. Add Siren Disable the Siren tamper switch by If there is any detector or Remote selecting “Siren A/T Off”...
  • Page 23: Operation

    button on the Remote Controller or triggering The Control Panel is battery powered, to conserve the the sensor, if the Control Panel received the battery power and to prolong the battery life, the signal, it will sound a high volume door chime Control Panel is put in Power Saving mode in the and the display will show you which sensor following two cases.
  • Page 24: Stopping The Exit Delay

    system, it will beep once and the strobe will flash once after the Exit Delay has A flashing cursor will underline the first character of expired. the menu selected; the total menu list consists of: A w a y A r m 2.
  • Page 25: Entering The Home Mode

    Remote Keypad Remote You can also put the system into the Controller. Home mode by pressing the “Home” button on the Remote Controller and the 2. Door Chime Remote Keypad, however, there will be no Exit Delay by this command. If an “Entry”...
  • Page 26: Disarmed Mode

    attribute is triggered again, the Control During the Entry Delay period, if a sensor with Panel will activate the alarm immediately. Instant attribute is triggered, the Control Panel will activate the alarm immediately, otherwise the If “Home Delay” Door Contact or PIR is control Panel will not respond.
  • Page 27: Stopping The Alarm

    Panel is sounded. will show the source of the alarm: 2. The Control Panel will sound swept frequency A l a r m e d P I R alarm tone in high volume. Z 0 1 ... . “Water Alarm”...
  • Page 28: Fault Message Display

    When any of Door Contact, PIR detector, Remote The Control Panel is capable of detecting Keypad or Control Panel is sabotaged, the Control following fault events: Panel will respond as below: Control Panel Low Battery When the system is in Disarmed mode, the Device Low Battery Control Panel will generate an Internal alarm Device and Control Panel Tamper...
  • Page 29: Installation

    “Tamp” means Tamper where “Rest”. is H o m e short for restore. I n t e r f e r e n c e L B . R e s t o r e Z 0 1 H A L L 4.
  • Page 30 Mounting Method The PIR is designed to be mounted on either a flat surface or in a corner situation with fixing screws and plugs provided. The base has knockouts, where the plastic is thinner, mounting purpose. Four knockouts are for surface fixing and four Enable the Control Panel Tamper protection knockouts are for corner fixing as shown in in the Programming mode under General...
  • Page 31 Step 9. Insert the wall plugs if fixing it into plaster degreaser. or brick. Step 2. Remove the protective covering from one Step 10. Screw the base into the wall plugs side of the double-sided adhesive pad and firmly apply to the back of the Step 11.
  • Page 32 enable the LED indicator to flash every Contact remotely. time the Door Contact is operated. More than one window and door can be Step 2. Fit the base on the door frame using protected by a Open Contact using the either the double sided adhesive pad or additional magnet and extension magnet the screws provided.
  • Page 33: Changing The Batteries

    Extension Terminal alone with internal magnet switch being bypassed or to use both of them together. If you choose to have both of the internal magnetic Switch and Extension Terminal work together, then. When the protected door is being opened or the enteral device is triggered, the Open Contact is activated and will transmit a violation signal...
  • Page 34: Reset To Factory Default Setting

    Step 3. Release both the “ ” key and the The Control Panel can clear all programmed “RESET BUTTON” when a long beep is parameters by the following sequence: heard, “Enter Code” will be displayed. Step 1. Disable tamper protection by putting the Control Panel into Programming Mode.
  • Page 35 -press both 4 and 6 to trigger fire alarm Orange LED indicates Away Mode 13. A Key Orange LED flash indicates Home Mode. -press both 1 and 3 to trigger panic alarm Green LED indicates Disarm Mode. 14. Mounting Hole Green LED flash indicates failure due to the following reasons: 15.
  • Page 36 with regular signal transmissions for the Using the 2 mounting holes as a template, Control Panel display status mark off the hole positions in the most accordingly. appropriate place. Before shipment, the battery is pre-installed Insert the wall plugs if fixing into plaster or by the factory.
  • Page 37 Press “#”, HA2000K sounds a long beep Step 1 Remove one of the batteries and release the tamper Step 6. Press” ” twice to exit Test mode and Step 2 Press “3” while inserting the removed the installation is completed. battery back in Functions Overview: Step 3 Continue pressing “3”...
  • Page 38: Specifications

    Alarm record Complete the following information during installation for future reference when adding to your system and to assist Trouble Shooting. Type Detector Final Entry Away Home Zone Location Chime Type(s) device Exit Delay mode • Modulation/ Demodulation: FM Narrow You may make a note of your User Password and band over 15KHz bandwidth with Installer Password below.
  • Page 39 • • Rolling code for remote controls and Transmitted signals: Opening, Closing, keypads. Weak battery, Tamper, Tamper closed, • Supervision and Test Mode. Fixed code for other accessories with over • 16 millions possible combinations. Battery life: Over 3 years assuming 50 •...
  • Page 40 • French Speaking Weight : 190g Eden: 0033 825 560 650 Outdoor Siren / Flashlight HA2000E • 8 functions: Intrusion, Fire, arming + disarming confirmation, weak batteries, Germany: tamper, tamper fault, anti jamming. • Noise level: 104db @ 1m •...
  • Page 41 PROBLEM? Do not HESITATE to call us via our assistance hotline (at the end of the notice). Our technicians will have the pleasure to help you make a perfect installation.

This manual is also suitable for:

Ha2000y

Table of Contents