KIT CONTENTS The Alarm System should contain the following components. 1 x Control Panel 1 x Wirefree Motion Sensor 1 x Wirefree Door/Window Contact Detector 1 x Remote Controller Also included: 4 x 1.5V LR20 size battery 1 x 2m telephone connection lead SC401 Control Panel Installation &...
INTRODUCTION AND OVERVIEW SYSTEM ZONING ALARM DURATION The detector(s) may be set to operate on either Zone 1, This is the length of time that the alarm will sound for, Zone 2 or panic. For ease of alarm verification it is following an intrusion.
Page 3
LEARNING ID CODE In order to prevent any unauthorized attempt to operate or disarm your system, you must configure your system to accept radio signals only from your own system devices. All detectors and Remote Controllers have their unique ID code, the Control Panel must learn their codes individually for the system to operate correctly.
Page 4
PLANNING AND EXTENDING YOUR WIREFREE ALARM SYSTEM optimum security. Use this as a guide for your The following example below shows a typical property installation in conjunction with the recommendations incorporating the suggested positions for the Control contained in this manual for planning your intruder Panel, Motion and Door/Window Contact Detectors for alarm system.
CONTROL PANEL For remote controller, press any key on it so as to emit CHOOSING THE DETECTOR TYPE ID code to the Control Panel automatically. Zone 1 provides standard intruder monitoring with If failed refers to UI_Error indication for confirmation. normal ARM and PART-ARM function.
Page 6
further consideration should be given to keeping 4. Refit battery cover. the units out of their reach. 5. Connect the Control Panel to the telephone connection lead by inserting small RJ11 plug into 3. The Control Panel should be mounted within a socket.
Page 7
down the Control Panel to get into the L-shaped metal mounting bracket. 8. Tighten the screw on the L-shaped metal mounting bracket to secure the Control Panel.
Page 8
A. Panic LED I. Keyhole Slot B. Zone 2 LED J. Tamper Switch C. Zone 1 LED K. RJ11 D. STATUT LED L. AC Adapter Socket E. Low battery LED M. Cable Track F. Microphone N. L-shaped Metal Mounting Bracket G.
*1: During alarm condition, LED flashes once every second. *2: LED will flash according to the corresponding zone number. *3: The low battery LED can be cleared when the system enters test mode. *4: Under chime mode, it will reveal via UI_Dingdong. *5: Zone trigger will be occurred only under arm mode.
TESTING THE SYSTEM across the devices field of vision. If movement is detected an alarm signal will be emitted. With the Control Panel in Disarm Mode Note: Motion Sensors will also detect animals, so ensure that pets are not permitted access to areas Press fitted with Motion Sensors when the system is armed.
Page 11
Note: When the system is armed, household pets should not be allowed into an area protected by a motion sensor as their movement would trigger the motion sensor and generate an alarm. INSTALLING THE MOTION SENSORS Ensure that the system is in Test Mode. 1.
Page 12
3. Using the rear cover as a template, mark the 1. DIP1 of SW2 is used to configure the Motion positions of the fixing holes on the wall. Sensor for walk test mode, which allows the operation of the sensor to be checked during 4.
Page 13
Control Panel will ding dong. Normal High/Low LED does not light up. mode Sensitivity If necessary adjust the detection range by changing the mounting position of the PCB within In summary, the setting of DIP1 & DIP2 of SW2 is the sensor housing.
Page 14
CHOOSING A MOUNTING LOCATION casing. 6. Fit the Magnet to the moving part of the The Door/Window Contact Detector is suitable for door/window opposite the Detector using the mounting in dry interior locations only. adhesive tape or 19mm fixing screws. Decide which doors/windows are to be protected by Ensure that the parallel gap between the Magnet Door/Window Contact Detectors, (usually the front and...
FACTORY DEFAULTS Disarm Mode Disarm User Access Code 1 2 3 4 Key Tone On (enable) Activation Type 1 Siren/Dialer enable Alarm Duration 1 minute Jamming Detection Off (disable) Entry Delay 15 sec Off (disable) Internal connection External wired connection for arm/part-arm DIP 1: ON Only the internal contact will be...
Page 16
DIP SWITCH There is a row of 8 DIP switches. These switches set the House Code for the Control Panel and must be set to the same ON/OFF combination as the House Code DIP switches in the wireless siren.
PROGRAMMING INSTRUCTIONS When full alarm condition occurs, disarm the alarm ARM MODE using remote controller, wireless keypad or the keypad on the Control Panel as mentioned above. Press RECORDING ALARM MESSAGE User access code Upon receipt of trigger signal, the Control Panel will Press generate alarm condition right away.
Page 18
press keypad ; Zone 2, press keypad confirmation. During input, any incorrect digit number whereas Panic zone, press keypad on the can be erased by pressing each time. Up to 4 Control Panel. set of phone numbers can be memorized. Note: It is recommended that the smoke detector and flood detector are assigned to panic zone.
Page 19
Default setting: siren/dialer enable seconds, the Control Panel will only dial up the first preset phone number. Press ALARM DURATION User access code ACTIVATION TYPE 2 This is the maximum length of time that the Control Panel will sound for, following an intrusion. Alarm This feature allows the dialer dial up the preset phone duration can be set for either 1 or 3 minutes.
is entered 3 times, the Control Panel will exit this mode of which UI indication refers to “UI_Error”. ENTRY DELAY Default setting: off Press User access code The entry delay is set for 15 seconds configured for arm and part-arm mode. The maximum allowable length of selecting entry delay for on or off is 15 seconds.
OPERATING INSTRUCTIONS switch on the remote controller or Control Panel. When leaving the premises, the system must be Armed. Control Panel However, before doing so, check that all windows are Press more than 3 seconds will generate full closed and locked, all protected doors are closed and alarm condition.
BATTERIES button has been pressed. Before removing the battery cover on any device to Under normal battery conditions the LED will replace the battery, ensure that the system is put into extinguish when the button is released. Test mode to avoid initiating an Alarm. Motion Sensors The specifications for replacement batteries are as Under low battery conditions the LED behind the...