Installer Testing; Operating Instructions - Heat & Glo ST-HVBI-AU Installation And Operation Instructions Manual

Fireplaces
Table of Contents

Advertisement

1.9 INSTALLER TESTING

The space heater must be tested and be operating accord-
ing to manufacturers specifications prior to the installer leav-
ing the site. Note: the tips of the flames should never hit
the top of the firebox after the unit has warmed up. Please
contact your dealer or a qualified service person to replace
injector or adjust valve.
Upon completing the gas line connection, a small amount
of air will be in the lines. When first lighting the pilot light, it
will take a few minutes for the lines to purge themselves of
this air. Once the purging is complete, the pilot and burner
will light and operate as indicated in the Lighting Instruc-
tions.
Subsequent lightings of the appliance will not require such
purging.
Follow the Safety Information and Lighting Instructions
pages of this manual to light the appliance.
To obtain proper operation, it is imperative that the pilot and
main burner flame characteristics are steady, not lifting or
floating. Typically, the top 3/8-inch (9.5mm) of the flame
sensor rod should be engulfed in the pilot flame (see Figure
36).
Pilot Assembly
Figure 36.
Heat & Glo • ST-HVBI-AU • 2082-900 Rev. C • 8/06
Figure 37.
Burner flame patterns are shown in Figure 37.
Follow TROUBLESHOOTING section for adjusting the ap-
pliance to operate properly.

2.0 OPERATING INSTRUCTIONS

This appliance is a balanced flue heater and is designed to
operate with all combustion air being siphoned from the
outside of the building and all exhaust gases expelled to
the outside of the building.
WARNING: THIS UNIT IS NOT FOR USE WITH
!
SOLID FUEL.
The control system for this model employs an electronic
pilot ignition. It consists of a 6V gas control valve/variable
regulator, an electronic module, a thermocouple and a re-
mote control. The controls are located in the lower com-
partment behind the lower door, and access is gained by
lifting the door up. See Figure 1.
WARNING: DO NOT CONNECT 220-240 VAC TO
!
THE GAS CONTROL VALVE OR CONTROL WIR-
ING SYSTEM OF THIS UNIT.
When lit for the first time, the appliance will emit a slight
odor for an hour or two. This is due to paint and lubricants
used in the manufacturing process. Additionally, for the first
few minutes after each lighting, vapor may condense and
fog the glass and the flames may be blue. After a few min-
utes this moisture will disappear and within 15-30 minutes
the flames should become yellow.
The heater may produce a noise, caused from metal expan-
sion and contraction as it heats up and cools down. This
noise is similar to one that a furnace or heat duct may pro-
duce and does not affect the operation or longevity of the
heater.
27

Advertisement

Table of Contents
loading

Table of Contents