If you are using a wireless wall thermostat or a
hand held thermostatic remote control, you can
locate the receiver behind the stove's back panel,
on the right end side, just below the terminal
block. Most receivers are already equipped with
quick-connect terminals. Simply unplug the PC
board wires connected to the back of the terminal
block and connect them directly with the receiver's
terminals. Location of the thermostat is very
important to obtain the best comfort and efficiency
from your ECO-65. The thermostat should be
mounted 50 inches from the floor on a wall
located 15 to 20 feet from the stove. You should
avoid an installation directly in front of the stove to
avoid cycling.(See figure 19)

2.13.2. Thermostatic mode

To use this mode, the "MODE" button must be pushed to "Thermostat" upon starting the stove. The heat
setting is then selected using the "Heat Level" selector "+ or –". When set in thermostatic mode, the stove
will automatically run at the heat level selected until the set room temperature is reached. When that occurs,
the stove will switch to heat setting #1 (lowest) until the thermostat calls for heat again. The convection
blower will also slow to its lowest speed. When the thermostat calls for heat again, the stove will increase its
feed rate to match the heat setting selected.
N.B.:
If the room temperature remains stable and the thermostat does not call for heat during at least
45 minutes, the stove will shut down. When the thermostat calls for heat again, the stove will start an ignition
cycle. Once the ignition cycle is completed, the stove will increase its feed rate to match the heat setting
selected.
FIGURE 19
Thermostat location
FIGURE 18
Rear view