CAMERA ELI‐EVC / ELI‐EEVC  USER MANUAL
 
2. Use the mounting base as a guide to mark the locations for screw and cable management holes 
on the mounting surface. Drill a starter hole at each marked location. Drill a cable management 
hole in the center at least 14mm in diameter to permit the camera's cable to be inserted 
through the mounting surface. If necessary, insert drywall anchors into the screw holes. 
3. Place the mounting base into location. Insert a screw through each of the screw holes in the 
base and into the mounting surface and then tighten each screw until the base is secure. 
4. Feed the camera's cable through the access hole; position the dome onto the mounted base, 
and twist the mounting ring clockwise to secure loosely. This will allow you to adjust the 
position of the hood and the camera. After the camera has been adjusted, tighten the mounting 
ring securely. 
Caution: Once power is supplied, do not remove the camera from the mounting base due to risk of 
electrical shock. 

Connections

1. Use a BNC connector to connect the camera's VIDEO OUT to the monitor's (or DVRs) VIDEO IN. 
Use the following recommendations for cable types and distances: 
Type of Coaxial Cable 
RG‐59/U 
Recommended Max 
250 M 
Cable Length 
825 ft 
 
2. The power is DC 12V (+/‐ 10%) / 350mA.  Use the following recommendations for cable types 
and distances: 
Copper Wire Size 
#24 
(AWG) 
(0.22 mm
Resistance (Ω/m) 
0.078 
Resistance (Ω/ft) 
0.024 
Use the formula below to calculate the power cord and power supply. "L", "R", "VA", "I" shall satisfy the inequality below: 
10.8  V DC ≤ VA ‐ 2 (R x I x L)  ≤ 16 V DC 
L = Cord length (m or ft) 
R = Resistance  of copper wire (Ω/m or Ω/ft} VA = DC output voltage of power supply unit  
I = DC current consumption (A). 
 
3. Connect power supply to the camera's POWER IN terminal.  
Maximum Cable Length 
RG‐6/U 
500 M 
1650 ft 
12V DC Recommended Wire Size and Resistance (68°F) 
#22 
2
(0.33 mm
0.050 
0.015 
Page | 6 
RG‐11/U 
600 M 
1980 ft 
#20 
2
2
(0.52 mm
0.03 
0.009 
 
     eLineTechnology.com 
RG‐15/U 
800 M 
2640 ft 
#18 
2
(0.83 mm
0.018 
0.005 