5.
Display shows
760 Watts continuous power.
Cycle inverter power OFF and ON.
If problem persists, use a larger inverter or a smaller
device.
6.
Display shows
Increase ventilation to inverter.
Move inverter to a cooler area.
Reduce the power consumption of the device.
Inverter will automatically reset after cooling.
PROBLEM: Inverter Does Not Turn On
Reason/Solution
Poor contact at terminals.
1.
Unplug and reinsert PID-760.
2.
fuse is blown.
A blown fuse is usually caused by reverse polarity or
a short circuit within the inverter. To replace, contact
a qualified service technician who will diagnose the
inverter and replace the fuse(s) with the appropriate
replacement(s).
.
Inverter may be defective.
See warranty and call Customer Service 800-621-5485
(Hours: 7 a.m. – 4:0 p.m. CST).
HiP
. Device demands more than
HoT
. Inverter is too hot.
9