  • Page 1 Domestic AC Fans – 230V Installation and Operating Guide 230V AC Base Models: iCON eco15 – 72683501 iCON15 – 72591501 iCON30 – 72591601 iCON60 – 72591701...
  • Page 2: Installation/Maintenance/Use

    The external opening should be covered by a suitable external grill, available separately from Airflow Developments Ltd. Airflow iCON / iCON eco Model Options 72683501 - eco15 -100mm Axial Fan with maximum capacity of 18.6 l/sec.
  • Page 3: Front Cover Removal

    Ensure free running of the fan impeller and that flexible duct connections are not over tightened to the fan outlet spigot. Airflow recommend that rigid ducting is used instead of flexible ducting, this will ensure maximum performance Front Cover Removal The front cover fan has a bayonet type fitting.
  • Page 4: Recessing Fans In The Wall

    Recessing Fans in the Wall The iCON 15 and iCON eco15 requires a 110mm diameter hole through the wall lined with a 100mm id (internal diameter) duct. The iCON30 requires a 110mm diameter hole through the wall, counter bored 160mm to a depth of 75mm.
  • Page 5: Surface Mounting Fans On Ceiling

    The iCON 15 and iCON eco15 requires a 110mm diameter hole through the ceiling. The fan should be fixed, with the screws provided, through the plaster board into the support. The iCON30 will require a 160mm diameter hole and the iCON60 a 190mm hole.
  • Page 6: Electrical Installation

    Electrical Installation All electrical installation to be carried out by an approved electrician in accordance with Part “P” U.K. Building Regulations and to the latest IEEE standards, or the appropriate regulations in the country of installation. iCON Domestic Fans require a 230V 50Hz supply, it is double insulated so therefore does not require an earth.
  • Page 7: Troubleshooting Tip

    Extended to 3 when registered @ airflow.com. Warranty only covers the fan, not the reinstallation of this if required. In the event of any defective parts being found, Airflow Developments Ltd reserve the right to repair or at our discretion replace without charge provided that the unit: 1.
  • Page 8: Range Of Optional Modules

    Web: airflow.de Fax: +44 (0) 1494 461073 Email: info@airflow.cz Email: info@airflow.com Web: airflow.cz Web: airflow.com AIRFLOW DEVELOPMENTS Limited reserve the right in the interest of continuous development to alter any or all specifications without prior notice. Page 8 of 8...