AEMC CA876 User Manual

Infrared k-thermometer with laser
Hide thumbs Also See for CA876:

Advertisement

Quick Links

CA876
INFRARED K-THERMOMETER
WITH LASER
E N G L I S H
User Manual

Advertisement

Table of Contents
loading

Summary of Contents for AEMC CA876

  • Page 1 CA876 INFRARED K-THERMOMETER  WITH LASER E N G L I S H User Manual...
  • Page 2 Owner’s Record The serial number for the Model CA872 is located inside the battery com- partment of the instrument. Please record this number and purchase date for your records. INFRARED THERMOMETER MODEL CA872 CATALOG #: 2121.31 SERIAL #: _______________________________________________ PURCHASE DATE: ________________________________________ DISTRIBUTOR: ___________________________________________...
  • Page 3: Table Of Contents

    Table of Contents 1. INTRODUCTION ..............2 1.1 International Electrical Symbols .............3 1.2 Receiving Your Shipment ...............3 1.3 Ordering Information ..............3 2. PRODUCT FEATURES ............4 2.1 Description ..................4 2.2 Button Functions ................5 2.2.1 Center (Yellow) Button - MEAS .........5 2.2.2 Mode Button ..............5 2.2.3 Back-light and ▲ Button ..........6 2.2.4 Laser and ▼ Button ............6 3. SPECIFICATIONS ..............7 3.1 Environmental Specifications .
  • Page 4: Introduction

    • Do not touch the sensor when taking measurements as it may affect the readings. • When the meter is exposed to sudden temperature changes (hot or cold), allow 20 minutes of stabilization before taking a reading. • Be certain there is no condensation on the lens prior to taking measurements. Allow 10 minutes for condensation to dissipate as needed. • The Model CA876 is not waterproof or dust-proof. Take necessary precautions to protect it in wet or dusty environments. • Repeated sharp flexing can cause the thermocouple leads to break. To prolong sensor life, avoid sharp bends in the thermo- couple, especially near the connector. Infrared K-Thermometer Model CA876...
  • Page 5: International Electrical Symbols

    Ordering Information Infrared Thermometer Model CA876........ Cat. #2121.34 Includes K-thermocouple, 9V Alkaline battery, rugged, shockproof, protective safety holster and user manual. Infrared K-Thermometer Model CA876...
  • Page 6: Product Features

    The thermometer is simply aimed at the target to be measured without any physical contact when in the IR mode (non-contact temperature mea- surement). An aiming laser enables the user to pinpoint the target. The K-type thermocouple input may also be used. The thermometer includes a programmable Alarm, which triggers on Hi or Lo, and a MIN or MAX Hold function. The thermometer is supplied with a protective holster, built-in sensor, and a K-type bead thermocouple. It also features a back-light LCD display, an automatic data HOLD function, and Auto-OFF. Auto OFF 1. 3½ digit display 2. Mode selector 3. Back-light/Increase button 4. Laser/Decrease button 5. Power/Measure button Infrared K-Thermometer Model CA876...
  • Page 7: Button Functions

    ALM Lo: The Lo alarm set point is adjusted using the  and  buttons. When this set point is reached the beeper will sound and ALM Lo will be displayed. MAX: The Max value measured will be displayed during measurement. While in the MAX mode and when measuring, the MODE button will toggle the mea- surement between MAX – MIN – Present reading – MAX. MIN: The Min value measured will be displayed during measurement. While in the MIN mode and when measuring, the MODE button will toggle the mea- surement between MIN – Present reading – MAX – MIN. K: The lower display will indicate the reading from the K-type thermocouple. NOTE: If the thermometer is OFF, pressing the “MEAS” button for more than 4 seconds will set the thermometer in the MIN/MAX record mode when pow- ered up. Infrared K-Thermometer Model CA876...
  • Page 8: Back-Light And ▲ Button

    ON or OFF. The symbol is displayed in the upper left hand corner when the laser is ON. Remove the laser cover before use. The laser is activated when the “MEAS” button is pressed during a mea- surement. ε In the settings , ALM Hi and ALM Lo, the  button decreases the numeri- cal value displayed in the lower smaller display area. If held down, the value change will decrease in speed. NOTE: There is no ON/OFF button. The meter turns ON when the center “MEAS” button is pressed, and will automatically shut OFF after approxi- mately 15 to 20 seconds. Infrared K-Thermometer Model CA876...
  • Page 9: Specifications

    3.1 Environmental Specifications 3.1.1 INFRARED Temperature Scale: Celsius (°C) or Fahrenheit (°F) user-selectable Temperature Range: -4°F to 1022°F (-20°C to 550°C) Display Resolution: 1°F / 1°C Accuracy: < 212°F (100°C) ± 10°F (5°C) > 212°F (100°C) ± 2% of Reading or ± 6°F (3°C), whichever is greater @ 64.4 to 82.4°F (18 to 28°C) ambient operating temperature. Temperature Coefficient: Changes in accuracy operating temperature above 82.4°F/28°C or below 64.4°F/18°C: ±0.2% of Reading or ± 0.36°F/0.2°C, whichever is greater. Response Time: 1 second Laser: Red, <1mW (670nm) Class II, 2 - 50 ft range Spectral Response: 6 to 14μm nominal Emissivity: Pre-set @ 0.95, user-selectable from 0.10 to 1.00 Detection Element: Thermopile Optical Lens: Fresnel Lens Infrared K-Thermometer Model CA876...
  • Page 10: K-Type

    0.1 times the applicable accuracy specification per °C from 0° to 18°C and 28° to 50°C Input Protection: or 24Vrms maximum input voltage on any combination of inputs Sample Rate: 2.5 times per second Input Connector: Standard miniature thermocouple connectors (flat blades spaced 7.9mm, center-to-center) Temperature Response: Temperature indication follows Reference Temperature/Voltage Tables N.I.S.T. Monograph 175 Revised to ITS-90 for K-type thermocouples Infrared K-Thermometer Model CA876...
  • Page 11: General Specifications

    Sample Rate: 2.5 times per second, nominal Operating Temperature: 32° to 122°F (0° to 50°C) at < 80% RH Storage Temperature: -4° to 140°F (-20° to 60°C), 0 to 80% RH with battery removed Auto Power Off: 15 seconds approx Altitude: 2000m max Input Protection: 24V or 24rms maximum input voltage on any combi- nation of inputs Battery: Standard 9V battery (NEDA 1604, 6LR61 or equivalent) Battery Life: 100 hours (continuity) typical with carbon zinc battery (back- light not illuminated) Dimensions: 6.81 x 2.38 x 1.5" (173 x 60.5 x 38mm) Weight: Approx 9 oz (255g) including battery 3.3 Safety Specifications EN 61010-1 (1995-A2), Protection Class III Overvoltage Category (CAT III, 24V), Pollution Degree 2 Indoor Use *All specifications are subject to change without notice Infrared K-Thermometer Model CA876...
  • Page 12: Operation

    Emissivity values range from 0.10 for a very reflective object to 1.00 for a black body. Factory set emissivity value of 0.95 will cover 90-95% of typical applications. If frost or other material/substance covers the measured surface, clean it to expose the surface. If the surface to be measured is highly reflective, apply dull masking tape or matte black paint over the surface. If the ther- mometer seems to be giving incorrect readings, check the front sensor. There may be condensation or debris obstructing the sensor. Only clean per instructions. Infrared K-Thermometer Model CA876...
  • Page 13: Recommendations Before Operating

    Recommendations before Operating • If the measured surface target diameter is less than 2"/50mm Ø, then place the sensor as close as possible to the target surface (<20"/50cm away). See Field of View (FOV) information under Specifications. • If the target surface is covered with frost or any matter, clean it before taking a measurement. • If the target surface is highly reflective put some matte tape, or matte paint, over it before measuring. • If the thermometer is erratic, or seems not to be measuring properly, make sure that the sensor is clean and not covered by condensation. Infrared K-Thermometer Model CA876...
  • Page 14: Infrared Operation

    6. If the measured temperature is outside the measurement range, will be displayed. 7. The thermometer will continue measuring as long as the MEAS button is pressed. When the button is released the measurement will be held in the display for 15-20 seconds. HOLD is displayed in the lower left- hand corner of the display. 8. The IR thermometer will shut OFF automatically after 15-20 seconds. K-Thermocouple Operation 1. Connect the K-thermocouple to the instrument input. 2. Press MEAS to turn the thermometer ON. 3. Press the MODE button (six times) to enter the thermocouple mode. K will be displayed in lower right hand corner of the display. 4. Put the thermocouple near or on the sample tested. 5. Press MEAS button to measure. Thermocouples need a certain time to respond. Take the reading when the measurement has stabilized. The reading is displayed in the smaller lower display in front of the K symbol. The main larger display is the IR temperature reading. 6. The thermometer will continue measuring as long as the MEAS button is pressed. When the button is released, the measurement will be held in the display for 15-20 seconds. Infrared K-Thermometer Model CA876...
  • Page 15: Setting The Temperature Scale: °C Or °F

    MEAS button. This will set the thermometer in the continuous mode. HOLD will not be displayed in the continuous mode and the laser sighting will not run. • When finished, press MEAS once. HOLD will be displayed and the thermometer will shut down in 15-20 seconds. Alternatively, press MEAS again to re-enter the continuous mode. Infrared K-Thermometer Model CA876...
  • Page 16: Maintenance

    CHAPTER 5 MAINTENANCE Use only factory specified replacement parts. AEMC will not be held ® responsible for any accident, incident, or malfunction following a repair done other than by its service center or by an approved repair center. Replacing the Battery The symbol appears on the LCD display when replacement is needed. Replace with a standard 9-volt alkaline battery (NEDA 1604, 6LR61). To replace the battery: • Turn the meter OFF. • Remove the rubber holster.
  • Page 17: Repair And Calibration

    NOTE: You must obtain a CSA# before returning any instrument. Technical and Sales Assistance If you are experiencing any technical problems, or require any assistance with the proper operation or application of your instrument, please call, mail, fax or e-mail our technical support team: Chauvin Arnoux , Inc. d.b.a. AEMC Instruments ® ® 200 Foxborough Boulevard Foxborough, MA 02035 USA Phone: (800) 343-1391 (508) 698-2115 Fax: (508) 698-2118 E-mail: techsupport@aemc.com www.aemc.com NOTE: Do not ship Instruments to our Foxborough, MA address. Infrared K-Thermometer Model CA876...
  • Page 18: Limited Warranty

    ® For full and detailed warranty coverage, please read the Warranty Coverage Information, which is attached to the Warranty Registration Card (if enclosed) or is available at www.aemc.com. Please keep the Warranty Coverage Information with your records. What AEMC Instruments will do: ®...
  • Page 19 Notes:...
  • Page 20 06/04 99-MAN 100246 v4 Chauvin Arnoux , Inc. d.b.a. AEMC Instruments ® ® 15 Faraday Drive • Dover, NH 03820 USA • Phone: (603) 749-6434 • Fax: (603) 742-2346 www.aemc.com...

This manual is also suitable for:

Ca872

Table of Contents