  • Page 1 K2000F DIGITAL THERMOMETER ST2-2000 TEMPERATURE PROBE Battery Test F˚ E N G L I S H User Manual...
  • Page 2 Limited Warranty The Thermometer Models K2000F and ST2-2000 are warranted to the owner for a period of 2 years from the date of original purchase against defects in manufacture. This limited warranty is given by AEMC Instru- ® ments, not by the distributor from whom it was purchased. This warranty...
  • Page 3: Table Of Contents

    Table of Contents 1. Description ..................3 2. Ordering Information .................4 3. Specifications..................5 Digital Thermometer Model K2000F ..........5 Temperature Probe Model ST2-2000..........5 Linearity Correction Curve ............6 4. Operation ..................7 5. Battery Replacement ................7 6. Sensors And Probe Extensions ............8 General Notes ................8 Isolation..................8...
  • Page 4: Description

    6. ON/OFF Push Button A range of 6 specialized sensors and interchangeable probe extensions are available to enable you to adapt the K2000F and ST2-2000 to suit your own requirements (see Section 6). Digital Thermometer Model K2000F and Temperature Probe Model ST2-2000...
  • Page 5: Ordering Information

    (-58°F to 482°F - Length = 5.9”) CK1 1M Extension Temperature Probe ....... Cat. #6529.09 CK2 2M Extension Temperature Probe ....... Cat. #6529.10 CK4 4mm Extension Temperature Probe ......Cat. #6529.14 Digital Thermometer Model K2000F and Temperature Probe Model ST2-2000...
  • Page 6: Specifications

    1850°F to 1999°F: 2% R plus linearity Operating Temperature: 32°F to 122°F (0°C to +50°C) Influence of Temperature: ± 1°C/10°C in reference range 68°F to 122°F (20°C to 50°C) (± 0.3% reading in other ranges) Digital Thermometer Model K2000F and Temperature Probe Model ST2-2000...
  • Page 7: Linearity Correction Curve

    Example: Reading: +1100°F Linearity Correction: -5°F Corrected Reading: 1100°F ± 1% ± 2°F = ± 13°F 1100°F - 5°F = 1095 ± 13°F Deg. F Digital Thermometer Model K2000F and Temperature Probe Model ST2-2000...
  • Page 8: Operation

    4. OPERATION • Select the range required: up to +200°F or +2000°F for Model K2000F or select mV input for Model ST2-2000. • Make sure that the sensor connected is suitable for the measurement about to be taken. • Position the sensor at the point of measurement.
  • Page 9: Sensors And Probe Extensions

    (intrinsic response time). If the thermal medium is unfavorable (e.g. calm air) the actual response time could attain 100 times or more of the thermocouple itself. Values for the K2000F and ST2-2000 sensors have been established under the following conditions: •...
  • Page 10: Sensors

    Hold the probe perpendicular to the surface to ensure good contact. The surface should be flat. Change the position of the probe slightly if necessary to obtain the highest reading. The use of silicon grease can improve the contact quality. Digital Thermometer Model K2000F and Temperature Probe Model ST2-2000...
  • Page 11: Surface Sensor Sk5

    During measurement in still air conditions, it is recommended that the probe should be waved from side to side, or up and down if you prefer. Digital Thermometer Model K2000F and Temperature Probe Model ST2-2000...
  • Page 12: Extension Leads

    (type K thermocouples), thus enabling connection of the SK1 to SK7 sensors range. The black plug corresponds to the thermocoupler “–” and the red to “+”. Digital Thermometer Model K2000F and Temperature Probe Model ST2-2000...
  • Page 13: Repair And Calibration

    Chauvin Arnoux , Inc. ® d.b.a. AEMC Instruments ® Phone: (800) 343-1391 (508) 698-2115 Fax: (508) 698-2118 www.aemc.com Digital Thermometer Model K2000F and Temperature Probe Model ST2-2000...
  • Page 14 08/18 99-MAN 100248 v2 Chauvin Arnoux , Inc. d.b.a. AEMC Instruments ® ® 15 Faraday Drive • Dover, NH 03820 USA • Phone: (603) 749-6434 • Fax: (603) 742-2346 www.aemc.com...