AEMC CA872 User Manual

Infrared thermometer with laser
Hide thumbs Also See for CA872:

Advertisement

Quick Links

CA872
INFRARED THERMOMETER
WITH LASER
E N G L I S H
User Manual

Advertisement

Table of Contents
loading

Summary of Contents for AEMC CA872

  • Page 1 CA872 INFRARED THERMOMETER  WITH LASER E N G L I S H User Manual...
  • Page 2 Owner’s Record The serial number for the Model CA872 is located inside the battery com- partment of the instrument. Please record this number and purchase date for your records. INFRARED THERMOMETER MODEL CA872 CATALOG #: 2121.31 SERIAL #: _______________________________________________ PURCHASE DATE: ________________________________________ DISTRIBUTOR: ___________________________________________...
  • Page 3: Table Of Contents

    Table of Contents 1. INTRODUCTION ..............2 1.1 International Electrical Symbols .............3 1.2 Receiving Your Shipment ...............3 1.3 Ordering Information ..............3 2. PRODUCT FEATURES ............4 2.1 Description ..................4 2.2 Button Functions ................5 2.2.1 Center (Yellow) Button - MEAS .........5 2.2.2 °C/°F Button ..............5 2.2.3 Back-light Button ...............5 2.2.4 Laser Button ..............5 3. SPECIFICATIONS ..............6 3.1 Electrical Specifications ..............6 3.2 General Specifications ..............7 3.3 Safety Specifications ..............7 4.
  • Page 4: Introduction

    • To prevent measurement errors, do not expose the thermom- eter to strong electrical or electromagnetic fields. • To prevent sensor damage and erroneous readings, do not put the sensor lens into contact with any body or foreign/loose material when measuring. Keep the sensor perfectly clean. • Do not touch the sensor when taking measurements as it may affect the readings. • When the meter is exposed to sudden temperature changes (hot or cold), allow 20 minutes of stabilization before taking a reading. • Be certain there is no condensation on the lens prior to taking measurements. Allow 10 minutes for condensation to dissipate as needed. • The Model CA872 is not waterproof or dust-proof. Take necessary precautions to protect it in wet or dusty environments. Infrared Thermometer Model CA872...
  • Page 5: International Electrical Symbols

    Save the damaged packing container to substantiate your claim. 1. Ordering Information Infrared Thermometer Model CA872........ Cat. #2121.31 Includes 9V Alkaline battery, rugged, shockproof, protective holster and user manual. Infrared Thermometer Model CA872...
  • Page 6: Product Features

    CHAPTER 2 PRODUCT FEATURES Description The AEMC Model CA872 is a portable, easy-to-use, compact-sized digi- ® tal infrared thermometer designed for simple one-hand operation. It uses an infrared sensor with a fixed emmisivity of 0.95. The thermometer is simply aimed at the target to be measured without any physical contact (non-contact temperature measurement). An aiming laser enables the user to pin-point the target. The thermometer is supplied with a protective holster and built-in sensor. The CA872 also features a back-light LCD display, an automatic data HOLD function, and Auto-OFF. IR THERMOMETER Model CA872 °C/°F Auto OFF MEAS 1. 3½ digit display 2. Temperature selector 3. Back-light button 4. Laser ON/OFF button 5. Power/measure button Infrared Thermometer Model CA872...
  • Page 7: Button Functions

    When the button is released, the meter will automatically HOLD (freeze) the last reading on the display for approximately 20 seconds before auto- matically shuting OFF. 2.2.2 °C/°F Button Pressing this button makes the thermometer toggle between °F and °C. The selected temperature type is displayed in the lower right hand corner of the LCD. At power-up, the thermometer is in °C by default. 2.2.3 Back-light Button Press the button to turn the Back-light ON. Press again to turn OFF. 2.2.4 Laser Button Pressing the button turns the laser ON or OFF. The symbol is displayed in the upper left hand corner when the laser is ON. Remove the laser cover before use. The laser is activated when the “MEAS” button is pressed during a mea- surement. NOTE: There is no ON/OFF button. The meter turns ON when the center “MEAS” button is pressed, and will automatically shut OFF after approxi- mately 20 seconds. Infrared Thermometer Model CA872...
  • Page 8: Specifications

    When the target diameter is small, it is Distance to object (mm) important to bring the ther- 1000 mometer closer to the target to ensure that only the target is measured, excluding the surroundings. Remember that the measurement size is one-tenth the dis- tance to the target. For example, if the thermometer is at 10", then the size measured is 1". Infrared Thermometer Model CA872...
  • Page 9: General Specifications

    Sample Rate: 2.5 times per second, nominal Operating Temperature: 32° to 122°F (0° to 50°C) at < 80% RH Storage Temperature: -4° to 140°F (-20° to 60°C), 0 to 80% RH with battery removed Auto Power Off: 15 seconds approx Altitude: 2000m max Input Protection: 24V or 24rms maximum input voltage on any combi- nation of inputs Battery: Standard 9V battery (NEDA 1604, 6LR61 or equivalent) Battery Life: 100 hours (continuity) typical with carbon zinc battery (back- light not illuminated) Dimensions: 6.81 x 2.38 x 1.5" (173 x 60.5 x 38mm) Weight: Approx 6.5 oz (183g) including battery 3.3 Safety Specifications EN 61010-1 (1995-A2), Protection Class III Overvoltage Category (CAT III, 24V), Pollution Degree 2 Indoor Use *All specifications are subject to change without notice Infrared Thermometer Model CA872...
  • Page 10: Operation

    Infrared radiation, which is emitted from the object, is focused into an infra- red radiation sensor through an optical system. This system includes an optical lens, which is transparent to infrared radiation, and a 5.3μm cut off filter. The output signal from the infrared radiation sensor is input to an electronic circuit, along with the output signal from a standard temperature sensor, to calculate the temperature and display it on the meter display. Recommendations before Operating • If the measured surface target diameter is less than 2"/50mm Ø, then place the sensor as close as possible to the target surface (<20"/50cm away). See Field of View (FOV) information under Specifications. • If the target surface is covered with frost or any matter, clean it before taking a measurement. • If the target surface is highly reflective put some matte tape, or matte paint, over it before measuring. • If the thermometer is erratic, or seems not to be measuring properly, make sure that the sensor is clean and not covered by condensation. Infrared Thermometer Model CA872...
  • Page 11: Operating Instructions

    0.80 to 0.95 Water 0.92 to 0.96 Lacquer (matte) 0.97 0.96 to 0.98 Rubber (black) 0.94 Snow 0.83 Plastic 0.85 to 0.95 Glass 0.90 to 0.95 Timber 0.90 Ceramic 0.90 to 0.94 Paper 0.70 to 0.94 Marble 0.94 Chromium oxide 0.81 Plaster 0.80 to 0.90 Copper oxide 0.78 Mortar 0.89 to 0.91 Iron oxide 0.78 to 0.82 Brick (red) 0.93 to 0.96 Textiles 0.90 Infrared Thermometer Model CA872...
  • Page 12: Maintenance

    CHAPTER 5 MAINTENANCE Use only factory specified replacement parts. AEMC will not be held ® responsible for any accident, incident, or malfunction following a repair done other than by its service center or by an approved repair center. Replacing the Battery The symbol appears on the LCD display when replacement is needed. Replace with a standard 9-volt battery (NEDA 1604, 6LR61). To replace the battery: • Turn the meter OFF. • Remove the rubber holster.
  • Page 13: Repair And Calibration

    NOTE: You must obtain a CSA# before returning any instrument. Technical and Sales Assistance If you are experiencing any technical problems, or require any assistance with the proper operation or application of your instrument, please call, mail, fax or e-mail our technical support team: Chauvin Arnoux , Inc. d.b.a. AEMC Instruments ® ® 200 Foxborough Boulevard Foxborough, MA 02035 USA Phone: (800) 343-1391 (508) 698-2115 Fax: (508) 698-2118 E-mail: techsupport@aemc.com www.aemc.com NOTE: Do not ship Instruments to our Foxborough, MA address. Infrared Thermometer Model CA872...
  • Page 14: Limited Warranty

    ® For full and detailed warranty coverage, please read the Warranty Coverage Information, which is attached to the Warranty Registration Card (if enclosed) or is available at www.aemc.com. Please keep the Warranty Coverage Information with your records. What AEMC Instruments will do: ®...
  • Page 15 Notes:...
  • Page 16 06/04 99-MAN 100245 v3 Chauvin Arnoux , Inc. d.b.a. AEMC Instruments ® ® 15 Faraday Drive • Dover, NH 03820 USA • Phone: (603) 749-6434 • Fax: (603) 742-2346 www.aemc.com...

Table of Contents