represents a surface temperature of 90F° (50C°) above room temperature.
ued ...
It is the installer's responsibility to ensure that building materials with a low heat tol-
erance which may degrade at lower temperatures are protected to prevent degrada-
tion. Examples of low heat tolerance materials include vinyl siding, fabrics, some
plastics, filmy materials, etc.
VENT END CLEARANCE: Clearances from the vent pipe are determined by local or national
installation codes, but must not be less than 6 inches (15 cm). For 'unvented' installation, a
minimum distance of 24 inches (61 cm) is required from the end of heater to a combustible
surface.
WARNING
maintain the required clearances from the heater to the combustibles.
The signs must be posted either adjacent to the IR heating system thermostats or in the ab-
sence of such thermostats, in a conspicuous place.
For your convenience a "peel and stick" sign
is provided with this heater. Use a permanent
marker to record the required dimensions on
the sign.
To calculate the value 'H': (H = T - C)
 Measure the on site distance between bottom of
the heater and the floor = 'T' inches (cm).
 Refer to Table 1 to get the value 'C' that corre-
sponds to the model you are installing
 Subtract the clearance below the heater 'C' from
'T' to get value 'H'.
 Enter this value 'H' on the sign.
Refer to the information for the heater model
being installed in Figure 1 and Table 1 to get
the values for dimensions 'S', 'F' and 'B'.
S100/ITB I&O Manual
IM101230
RD: JAN 2012
RL: 6B- BA
In locations used for the storage of combustible materials: Signs
must be posted specifying the maximum permissible stacking height to
Post this sign as instructed above.