American Eagle SHD-138 Owner's Manual

Hydraulic air compressor

Advertisement

Quick Links

Owner's Manual
Safety, Installation, Maintenance, and Operation
Model SHD-138
American Eagle, Inc.
740 N. State Street
PO Box 169
Garner, IA 50438
800-392-3015
Fax: 641-923-9099
www.americaneagleacc.com
Subject to Change without Notification.
Last Revision: 01/27/12
© 2012 American Eagle

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SHD-138 and is the answer not in the manual?

Questions and answers

Summary of Contents for American Eagle SHD-138

  • Page 1 Owner’s Manual Safety, Installation, Maintenance, and Operation Model SHD-138 American Eagle, Inc. 740 N. State Street PO Box 169 Garner, IA 50438 800-392-3015 Fax: 641-923-9099 www.americaneagleacc.com Subject to Change without Notification. Last Revision: 01/27/12 © 2012 American Eagle...
  • Page 2 This manual please contact AE Technical Support at 800- is not binding. American Eagle reserves the 321-3741 or email at right to change, at any time, any or all of the service@americaneagleacc.com...
  • Page 3: Table Of Contents

    Table of Contents Safety Page 3 Specifications Page 4 Operation Page 5 Head Unloading System Page 6 Maintenance Page 7 Installation Page 8 Assembly Drawings Page 12 Replacement Parts Page 16 Troubleshooting Page 17 Warranty Page 19 SHD-138 Manual...
  • Page 4: Safety

    Carefully read the operators manual before starting the unit. Failure to adhere to the instructions could result in serious bodily injury or property damage. The SHD-138 Hydraulic Air Compressor will all hose connections are tight, both air and provide safe and dependable service if operated hydraulic.
  • Page 5: Specifications

    800 lbs. (dry) • Delivery: 60 SCFM @ 175 PSI • Maximum Working Pressure: 175 PSI • Electrical: 12 VDC @ 10 amp • Crankcase Oil Capacity: 4 Quart • Cylinders: Two Cylinder(Dual Stage) • Maximum Compressor Speed: 1000 RPM SHD-138 Manual...
  • Page 6: Operation

    145 psi Never use plastic pipe or improperly rated metal and the air pressure valve disengages the pipe. Improper piping materials can burst and intake valve hold-open mechanism to allow the cause injury or property damage. SHD-138 Manual...
  • Page 7: Head Unloading System

    4.) Be careful not to move the threaded cap (1). 3.) After pressure is set, tighten locknut (2). Be careful Differential Pressure Adjustment: Proceed with the not to move nut (3) following while the compressor is running. SHD-138 Manual...
  • Page 8: Maintenance

    The following table is a list of routine maintenance items, including service intervals. Service intervals are listed as hours, days, or weeks, whichever occurs first. American Eagle recommends that these service intervals be followed. Before performing any maintenance function “Lock Out” or “Tag Out”...
  • Page 9: Installation

    The electric speed control installation of the PTO. (American Eagle P/N C0873) is used on most gasoline engines. The electronic speed controls Compressor Assembly: are used only on Ford 6.0 and 7.3L diesel Prepare the mounting location of the engines.
  • Page 10 Note: The case drain line from the hydraulic motor is also routed to the oil reservoir. American Eagle recommends a sufficient sized reservoir be provided which includes the proper suction and return filters. The cooler on the compressor is designed and sized to cool the air compressor efficiently.
  • Page 11 Typical Hydraulic Circuit for Single Stage Pump with PN 30533 Multiple Components Typical Hydraulic Circuit for Tandum (Two Part) Pump with PN 30532 Multiple Components SHD-138 Manual...
  • Page 12: With Auxiliary Cooler

    Typical Hydraulic Circuit for Compressor with Auxiliary Cooler HYDRAULIC RESERVOIR FILTER FILTER SCREEN AUXILIARY COOLER SUCTION PORT SINGLE HYDRAULIC PUMP COMPRESSOR RETURN PRESSURE SHD-138 Manual...
  • Page 13: Assembly Drawings

    FTG 0.75-45 DEG ELBOW BRASS C2274 FTG HOSE BARB .25 HOSE X .25 MNPT D0847 BRKT 11.00 TWIST 45 DEG SHD66DD B0843PC ANGLE TIGHTENER CPRSR WLDMT C1088 CPRSR CHMP R40A-HU 8697 CAP SCR 0.50-13X6.00 ALL THREAD GR5 C4941 CLAMP MUFFLER 1 1/8 SHD-138 Manual...
  • Page 14 R40 Breakdown Assembly SHD-138 Manual...
  • Page 15 ” , t e t ” , t e t ” e l f l f f l l a Connecting rod assembly (includes items 43, 44, 45 & 46) Z658 n i l a l f SHD-138 Manual...
  • Page 16 & e t i & Z656 Valve set with gaskets (items 60, 61, 62, 63, 64, & 66) e t i & Intake manifolds shown for Start-Stop units only. See page 26 for Head Unloader manifolds. SHD-138 Manual...
  • Page 17: Replacement Parts

    13731 Valve Assembly (Low Pressure Intake) 13732 Valve Assembly (Low Pressure Exhaust) 13733 Valve Assembly (High Pressure Intake) 13734 Valve Assembly (High Pressure Exhaust) 4563 Complete Valve Gasket Set 4564 Complete Valve Set W/Gaskets C1183 Pressure Relief Valve SHD-138 Manual...
  • Page 18: Troubleshooting

    Clean or replace check valve. Dirty after cooler or intercooler tubing. Remove and clean. Compressor runs hot: Faulty compressor values. Clean or replace valves. Dirty intake muffler. Clean or replace. Low crankcase oil level. Add compressor oil as needed. SHD-138 Manual...
  • Page 19 Check valve leaking. Clean or replace. Chassis engine RPM Faulty pressure switch. Replace pressure switch. continue to operate at high speed when air receiver Pressure switch wiring. Wires place on pressure switch incorrectly or reaches maximum capacity: loose ground wire. SHD-138 Manual...
  • Page 20: Warranty

    Warranty service will be performed by any American Eagle new equipment distributor, or by any American Eagle-recognized service center authorized to service the type of product involved, or by the American Eagle factory in the event of a direct sale. At the time of requesting warranty service, the owner must present evidence of date of delivery of the product.