Specifications
Function
Range and Resolution
Humidity
10.0 to 90.0%RH
90.0 to 100.0%RH
Temperature
Wet Bulb
0 to 80°C (32 to 176°F)
Dew Point
-30 to 100°C (-22 to 199°F)
0 to 1120 GPP (grains per pound)
Mixing Ratio
0 to 160 g/kg (grams per kilogram)
Display
Response Time:
Operating Conditions 0 to 50
Storage Conditions
Power Supply
Battery Life
Dimensions / Weight 200 x 45 x 33mm (7.8 x 1.7 x 1.3"); 200g (7 oz.)
Copyright © 2009 Extech Instruments Corporation
All rights reserved including the right of reproduction in whole or in part in any form.
0.0 to 10.0%RH
o
-22.0 to – 3.9
F
o
-30.0 to -19.9
C
o
-20.0 to 70.0
C
o
-4.0 to 158.0
F
o
70.1 to 100.0
C
o
158.1 to 199.0
F
Dual LCD
<30 seconds (90% of final value in moving air)
o
o
C (32 to 122
F); < 80% RH non-condensing
o
o
-40 to 85
C (-40 to 185
F); <99% RH non-condensing
9 Volt battery
Approx. 24 hours
6
Accuracy
±3%RH
±2%RH
±3%RH
o
±2.7
F
o
±1.5
C
o
±1
C
o
±1.8
F
o
±1.5
C
o
±2.7
F
Calculated from RH and air
temperature measurements
RH490-EU V2.0 12/06