UT4500 Series Up Converter
Remote Control
5.6.4.10 P
ACKED
Packed Alarm Status:
Confirmation:
where:
5.6.5 S
TORED
The 100 alarms are date/time stamped and stored in memory as they occur. The alarm
entry is also updated with its date/time of clearance. The entry remains in memory until
it is removed by command.
5.6.5.1 T
S
OTAL
This command retrieves the total number of stored alarms and the time and date of the
most recent alarm.
Retrieve Total Alarms:
Confirmation:
where:
5.6.5.2 C
A
LEAR
Clear Alarms:
Confirmation:
A
S
LARM
TATUS
<DEV/PACRAS_'cr'
>DEV/PACRAS_abcdefghijk'cr''lf']
a = 1 if V15 Fault, else 0
b = 1 if V14 Fault, else 0
c = 1 if VCC Fault, else 0
d = 1 if V5D Fault, else 0
e = 1 if TEMP Fault, else 0
f = 1 if IFLO Fault, else 0
g = 1 if SUM Fault, else 0
h = 1 if COARSE Fault, else 0
I = 1 if FINE Fault, else 0
j = 1 if HSB Fault, else 0
k = 1 if EXT REF Fault, else 0
A
LARM
A
TORED
LARMS
<DEV/TSA_'cr'
>DEV/TSA_TOTAL:nn'cr'
LAST:hh:mm:ss mm/dd/yy'cr''lf']
nn = 0 to 99; the 100
hh.mm.ss = time in hour:minute:second
mm/dd/yy = date in month/day/year
S
A
LL
TORED
LARMS
<DEV/CAA_YES'cr'
>DEV/CAA_CLEARED'cr''lf']
th
alarm will be ER