QuickSpecs
Configuration Information
HP 36GB 3G 15K 2.5-inch SAS SFF SP HDD (MSA70 only)
HP 72GB 3G 15K 2.5-inch SAS SFF SP HDD (MSA70 only)
HP 72GB 3G 10K 2.5-inch SAS SFF DP HDD
HP 146GB 3G 10K 2.5-inch SAS SFF DP HDD
HP 36GB 3G 15K 2.5-inch SAS SFF DP HDD
HP 72GB 3G 15K 2.5-inch SAS SFF DP HDD
ProLiant Small Form Factor (SFF) SATA drives for MSA2324fc and MSA70 JBOD
ProLiant Small Form Factor (SFF) SATA drives for MSA2324fc and MSA70 JBOD
ProLiant Small Form Factor (SFF) SATA drives for MSA2324fc and MSA70 JBOD
ProLiant Small Form Factor (SFF) SATA drives for MSA2324fc and MSA70 JBOD
HP 60 GB 1.5 G 5.4K 2.5-inch SATA SFF HDD
HP 120 GB 1.5G 5.4K 2.5-inch SATA SFF HDD
Step 2c - Drive Enclosure Options
Step 2c - Drive Enclosure Options
Step 2c - Drive Enclosure Options
Step 2c - Drive Enclosure Options
Should you want a drive enclosure, the model you choose depends on which array model it attaches to. If it is a single controller
array, then choose the JBOD designated as "Single I/O". If it is attaching to a dual controller array then choose the "Dual I/O" JBOD
HP StorageWorks MSA2000 Single I/O 3.5-inch 12 Drive Enclosure
(use with single controller array heads. Ships with two .6m SAS to SAS cables)
HP StorageWorks MSA2000 Drive Enclosure I/O Module
(Use to upgrade the Single I/O model to dual I/O. No cable included)
HP StorageWorks MSA2000 Dual I/O 3.5-inch 12 Drive Enclosure
(use with dual controller array heads. Ships with two .6m SAS to SAS cables)
HP StorageWorks 70 Modular Smart Array (MSA70) SFF 2.5-inch drive Single I/O JBOD
Single I/O, single domain. 25 Small Form Factor (SFF) drive bays
(use only with MSA2324fc array head. Includes one miniSAS to miniSAS cable)
HP StorageWorks Dual Domain I/O Module for MSA70
Makes the standard MSA70 (above) into a dual I/O, dual domain JBOD
(Includes one miniSAS to miniSAS cable)
MSA70 NOTE:
MSA70 NOTE:
MSA70 NOTE: Only Dual Port (DP) drives will work in the Dual Domain environment. Dual Domain environment requires the HP
MSA70 NOTE:
StorageWorks Dual Domain I/O Module Option (# AG779A).
For more information on the MSA70, go to the MSA70 Home Page:
http://h18006.www1.hp.com/storage/disk_storage/msa_diskarrays/drive_enclosures/msa70/index.html
Step 2c - SAS Cable Options
Step 2c - SAS Cable Options
Step 2c - SAS Cable Options
Step 2c - SAS Cable Options
miniSAS to miniSAS Cables:
miniSAS to miniSAS Cables:
miniSAS to miniSAS Cables:
miniSAS to miniSAS Cables:
Connecting MSA2300fc controller to MSA70 JBOD if a longer cable is desired.
HP Ext miniSAS to miniSAS 1m Cable
HP Ext miniSAS to miniSAS 2m Cable
SAS to miniSAS Cables:
SAS to miniSAS Cables:
SAS to miniSAS Cables:
SAS to miniSAS Cables:
Connecting MSA2300fc controller to MSA2000 3.5-inch Disk Enclosure
HP SAS to miniSAS .5m Cable
HP SAS to miniSAS 1m Cable
HP SAS to miniSAS 2m Cable
SAS Cables (SAS to SAS)
SAS Cables (SAS to SAS)
SAS Cables (SAS to SAS)
SAS Cables (SAS to SAS)
Older MSA2000fc controller to MSA2000 3.5-inch Disk Enclosure or cascading two
MSA2000 3.5-inch Disk Enclosures if included .6m cables is not of sufficient length
HP Ext SAS to SAS 1m Cable
DA - 13187
EMEA — Version 2 — February 10, 2009
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart Array
HP StorageWorks 2000fc G2 Modular Smart Array
431933-B21
431935-B21
384842-B21
418367-B21
418369-B21
418371-B21
379306-B21
458924-B21
AJ749A
AJ751A
AJ750A
418800-B21
AG779A
407337-B21
407339-B21
419569-B21
419570-B21
419571-B21
389665-B21
Page 20