Connecting Cables (not included)
Power wire and wiring are very important to the
Secondary Icons
performance of the inverter. Because the inverter has a
low voltage, high current input, low resistance wiring is
essential between the battery and inverter. This is so it
can deliver the maximum amount of energy to the load.
Notice
Caution
Use only copper wire. Aluminum wire has about one-third
more resistance than copper wire of the same size, plus it
is difficult to make good, low-resistance connections to
aluminum wire.
We recommend #4 AWG copper cable (90°C insulation
rating) as the minimum size for connections between
the battery and inverter.
Keep the cable length as short as possible, no more
than four feet (one and a half meters). This will keep the
voltage drop to a minimum.
If the cable has too much voltage drop, the inverter may
shut down when drawing higher currents because voltage
at the inverter may drop below 10 volts. If you must use
Main Icons
longer cables, choose thicker cables, such as #2 AWG,
and trim the ends of the cable to fit the terminals.
To connect the cables between the
inverter and the battery:
Intro
1. Press the Power Button on the inverter to the off
position. If the power source is a DC power supply,
switch it off as well.
Power Button
Secondary Icons
8
Warranty
Notes
Warning
Operation
Customer
Warranty
Assistance
Installation
Notes
Notice
Caution
Warning
Intro
Operation
Installation
Installation
2. On the end of the cable that connects to the inverter,
strip back the insulation about one-half inch (one and
Secondary Icons
one-half cm), exposing the bare copper conductor.
Strip the Insulation
Notice
3. Connect cable to the Power Input Terminals on input
end of the inverter. The red terminal is positive (+) and
the black terminal is negative (-). Insert the bare ends
of the cables into the terminals and tighten the screws
to clamp the wires securely.
It is a good idea to check and tighten these screws
from time to time. They can become loose by
vibrations or thermal cycling.
Insert Bare Cables
4. Connect cables to the power source:
a. Connect the cable from the Negative (Black)
Terminal of inverter to the Negative Terminal
of the power source. Make a secure connection.