SECTION 2
PWRCHECK.DOC
12/22/92
2.16
2.16.1
2.16.2
2.16.3
2.16.4
2.16.5
2.16.6
2.16.7
2.16.8
K2000 POWER-UP CHECK OUT
VISUAL:
Inspect unit for signs of damage or omissions.
Verify the correct power entry module is configured
for proper AC voltage.
USA units should have white nylon dot in the 120
volt positions.
When converting to another voltage; fuse value may
require change.
(Refer to appendix 4 of Musicians Guide)
POWER UP:
Normal sequence is: LCD back light comes on.
All eight LEOs blink in unison once.
LCD displays "Welcome" message.
Program mode LED lights and LCD displays Program
mode data.
(Refer to chapter 2 of Musicians Guide)
LEOs BLINK TWO TIMES:
If the Pitch Wheel range is not within 120 to 136
range.
LEOs BLINK THREE TIMES:
If the battery voltage is below 3.2 volts.
Note that scanner also reports a low voltage to the
engine board which will display low voltage.
POWER ON DIAGNOSTICS:
Power on diagnostics are limited.
The engine board
checks a few locations in non-volatile
RAM,
(program
RAM)
to determine whether to use stored data or
regenerate factory defaults.
The effects processor performs basically the same
type tests for its non-volatile
RAM.
SCANNER DIAGNOSTICS:
Test digital circuits portion of audio/power supply
board (appendix Al-3).
To enter this mode, press buttons 4, 5, and 6
together.
The eight LEOs should blink in order and
the display will display "K2061 Scanner ..• " etc.
BATTERY VOLTAGE:
4.2 Volts, three penlight cells
(AA
size).
Typically 4.2 to 4.3 volts.
Less than 3 volts, replace batteries or correct wire
connection.
WHEEL CENTER:
A minimum of 120 to a maximum 135, 127 or 128 is
mid-point.
Moving the pitch up or down should
11

Advertisement

loading