Clemco 60 HP Instruction Manual

Supplied-air respirator

Advertisement

Quick Links

NOTICE
This supplied air respirator conforms to all NIOSH
specifications and standards and carries NIOSH
approval. As manufactured, this respirator complies
only with those foreign approvals that accept NIOSH
certification. Specifically, it has not been manufactured
to European CE standards and does not carry the
European CE-mark.
© CLEMCO INDUSTRIES CORP.
One Cable Car Drive
Washington, MO 63090
Phone (636) 239-4300
Fax (636) 239-0788
APOLLO 60 HP SUPPLIED-AIR RESPIRATOR
CLEMCO SUPPLIED AIR RESPIRATOR
MC FILE NUMBER:
DATE OF ISSUE:
REVISION:
Do not proceed with
these instructions until
you have READ the
orange cover of this
MANUAL and YOU
UNDERSTAND its
content.* These
WARNINGS are
included for the health
and safety of the
operator and those in
the immediate vicinity.
*If you are using a Clemco
Distributor Parts and Maintenance
Guide refer to the orange warnings
insert preceding the Index before
continuing with the following
instructions.
®
MODEL 60 HP
O.M. 10533
690-0985
09/85
K, 05/15/98
W A R N I N G

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Clemco 60 HP and is the answer not in the manual?

Questions and answers

Summary of Contents for Clemco Clemco 60 HP

  • Page 1 APOLLO 60 HP SUPPLIED-AIR RESPIRATOR NOTICE This supplied air respirator conforms to all NIOSH specifications and standards and carries NIOSH approval. As manufactured, this respirator complies only with those foreign approvals that accept NIOSH certification. Specifically, it has not been manufactured to European CE standards and does not carry the European CE-mark.
  • Page 2 Scope of manual 1.1.1 This manual covers setup, operation, mainte- nance, replacement parts, and important warnings for safe operation of the Clemco Apollo 60 HP Supplied-Air Respi- rator. 1.1.2 OSHA requires the employer to establish a com- prehensive respiratory protection program per regulations 29 CFR 1910.134(a)(b) and 29 CFR 1926.103, to include...
  • Page 3 Exposure to dangerous levels of lead or other APOLLO 60 HP SUPPLIED-AIR RESPIRATOR toxic or hazardous dust is not restricted to blast operators. There may be an equal or greater...
  • Page 4 Refer to users instructions, and/or maintenance manuals for information on use and maintenance of these respirators. Special Use Limitations APOLLO 60 HP SUPPLIED-AIR RESPIRATOR 1.5.1 of attachment is where the respirator supply hose is connected to the respirable air source) must be main- tained at pressures between the minimum pressure as shown in the table in Section 4.2.4 and the maximum of...
  • Page 5 1.7.3 cessory kit contains parts and instructions to convert the Apollo 60 HP, (respirator for use with Grade “D” Com- pressed Air) to Apollo 60 LP (respirator for use with ambient air pump). The kit is listed in Section 10.1.
  • Page 6 If the gasket is not adequately supported, leaks can occur which could permit entry of toxic and hazardous dust or abrasive into the helmet. APOLLO 60 HP SUPPLIED-AIR RESPIRATOR 3.2.1 rator assembly. The helmet is supplied with an inner lens, secured by a thick rubber gasket.
  • Page 7: Air Supply

    G-7.1., titled Commodity Specification For Air, published by Compressed Gas Association Inc., Arlington, VA. (42 CFR Chapter 1). APOLLO 60 HP SUPPLIED-AIR RESPIRATOR 4.1.3 manual and all instructions, labels, and warnings relating to the compressed air source. Take special care to abide by all warnings from the compressor manufacturer regard- ing compressor use.
  • Page 8: Operation

    Use the table below to determine the minimum pressure setting and maximum respirator hose length, based on the air control device as shown in Section 1.7.2. APOLLO 60 HP SUPPLIED-AIR RESPIRATOR * Do not use these control devices at distances greater than 200 ft.
  • Page 9 Put the belt and control valve on over the cape. Buckle the belt around the waist, and tighten it by pulling the belt end through the buckle insert. APOLLO 60 HP SUPPLIED-AIR RESPIRATOR 5.11 the respirator in a clean, non-hazardous environment where the air is safe to breathe.
  • Page 10: Maintenance Program

    It is important that the adjustment be made evenly on both sides. Press the selected slots firmly onto the lugs on the front band. APOLLO 60 HP SUPPLIED-AIR RESPIRATOR 6.2.5 suspension. 6.2.6 suspension.
  • Page 11 Place the bag in a clearly marked carton and APOLLO 60 HP SUPPLIED-AIR RESPIRATOR store it in a clean, dry place. [Reference OSHA Regula- tions 1910.134 (f)(5)].
  • Page 12: Service & Maintenance

    Up to five outer lenses can be installed at one time. For maximum visibility, install only enough lenses to last during a work period. APOLLO 60 HP SUPPLIED-AIR RESPIRATOR Lens Replacement 9.2.2 permit lenses to be pulled off easily by a user wearing heavy gloves.
  • Page 13: Replacement Parts

    Cool-air tube with belt ... 04410 Climate control tube with belt ... 04411 Filter kit, air control valve ... 04381 Low pressure conversion kit. Converts Apollo 60 HP (high pressure) (Grade “D” Compressed Air) respirator to LP (low pressure, ambient air) respirator ... 22079 Page 12 Stock No.
  • Page 14 Adaptor, 3/8" hose to 1/4" pipe ... 01019 Acoustical foam kit, sides ... 04369 (16) (23) (18) (17) (24) (20) (21) APOLLO 60 HP SUPPLIED-AIR RESPIRATOR Stock No. (10) (11) (12) (15) (22) (19) Gasket, window ... 04452 Inner lens, .040" package of 5 ... 04367 Outer lens, .0075", perforated,...

This manual is also suitable for:

Clemco o.m. 10533Apollo 60 hp

Table of Contents