DO NOT modify or substitute any Clemco parts with other The products described in this material may be combined by types or brands of equipment. Unauthorized modification...
Page 3
ALWAYS attach safety cables at ALL air hose AND blast 1910.244). hose coupling connections. Cables relieve tension on hose and control whipping action in the event of a coupling blow-out. • NEVER modify OR substitute remote control parts. Parts from different manufacturers are NOT compatible with Clemco...
• Training and Educational Programs. free of the rightful claim of any third party by way of patent Clemco Industries Corp. offers a booklet, Blast-Off 2, infringement or the like. developed to educate personnel on abrasive blast equipment 6. This warranty is conditioned upon seller’s receipt within ten function and surface preparation techniques.
Page 5
PREFACE □ □ 3. Clean, properly maintained NIOSH-APPROVED 8. BLAST HOSE with ID 3 to 4 times the nozzle orifice. SUPPLIED-AIR RESPIRATOR. ALL components should Lines MUST be run AS STRAIGHT AS POSSIBLE from ALWAYS be present. NEVER operate without inner lens in machine to work area with NO sharp bends.
Page 6
CMS-2 Carbon Monoxide Monitor ....22925 components with this respirator. Safety Alerts 1.2.1 Clemco uses safety alert signal words, based on ANSI Z535.4-1998, to alert the user of a potentially hazardous situation that may be encountered while operating this equipment. ANSI’s definitions of the signal words are as follows: This is the safety alert symbol.
Page 8
1000 to all Apollo Series Respirators based on the simulated workplace protection factor studies Cautions and Limitations Clemco has performed. These studies are available A - Not for use in atmospheres containing less than 19.5 for download from Clemco’s Website percent oxygen.
Page 9
NOTE: If the respirator does not include an approved Clemco respirator hose, and if one is not at the work site 1.8.3 Face and Eye: The Apollo inner lens meets for use with the respirator, one or more alternate hoses impact and penetration requirements under ANSI Z87.1-...
Page 11
Use any " the respirator in this manner may damage the 25-foot, 50-foot and 100-foot Clemco respirator hoses in tube or helmet inlet. Any leaks or breaks in the any combination as noted in the table in Section 4.4, not breathing tube will alter the air flow through the to exceed 300 ft.
The employer is responsible for ensuring that CMS-3 CO Monitor Option, Respirator Mounted The Clemco supplied air respirator model Apollo 600 HP breathing air shall meet the requirements for Grade D or is NIOSH approved with the accessory CMS-3 personal...
4.4.3.1 This optional accessory kit contains parts and inside. Holding the chin strap while donning the helmet instructions to convert an Apollo 600 respirator from high will make it easier to position it once the helmet is on. pressure (65 to 100 psi) to low pressure (6 to 20 psi).
Page 15
6.1.1 Web Suspension with Sweatband 6.2.1 Clemco’s ACV air-control valve allows the user to increase or decrease the volume of breathing-air while 6.1.1.1 Remove the cape from the helmet per Section wearing the supplied-air respirator. The valve provides a 9.4.
Connect the breathing tube and use the tube for leverage to tighten the inlet fitting. Do not use a wrench Apollo 600 HP Less Respirator Hose, with: to tighten the fitting, as it may damage the helmet. Leave the breathing tube connected until the cyanoacrylate has Description Stock No.
Page 22
APOLLO HIGH PRESSURE SUPPLIED-AIR RESPIRATOR Page 17 HELMET MODEL 600 10.4 Accessories 10.2 Apollo 600 HP DLX Supplied-Air Respirator Systems with DLX Padded Suspension and Description Stock No. Alternate Accessories Hearing protection muffs, Apollo 600 HP DLX Supplied-Air Respirator Low profile noise reduction muffs Less Respirator Hose, with: for use with web suspension w/sweatband only.