Quincy Compressor QSD 65040-AB Instruction Manual page 55

Oil-free rotary screw air compressor
Table of Contents

Advertisement

Power$ync II
uses military time (i.e., 8:00AM is 08:00
and 2:00PM is 14:00).
TIME MENU
TO VIEW CURRENT TIME
TO SET TIME AND DATE
PRESS ENTER TO RETURN
To view the current time and date without changing
them, press F1.
TIME AND DATE MENU
CURRENT TIME ON THIS CONTROL
CURRENT DATE ON THIS CONTROL
PRESS ENTER TO RETURN
Press ENTER to return the display to the Time
Menu.
To reset the time and date, press F2 at the Time Menu.
Because changing the time or date can disrupt schedule
information, the control will display the following
warning:
NOTICE
YOU ARE ABOUT TO RESET THE CLOCK
TO CHANGE THE TIME AND DATE
TO ABORT PRESS ENTER
Press F3 to move the display to the Set Time Menu.
SET TIME MENU
CURRENT TIME
PRESS ENTER TO ACCEPT VALUE
When this menu is displayed, the hours number
will be flashing. Use the UP or DOWN arrow key
to change the hour setting. When the hour setting
is correct, press ENTER, the minute setting will
now be flashing. Follow the above procedure to
change the minute setting and press ENTER to
accept the change. The control will briefly display
a message that it is transferring the new time
setting to all on-line compressors. There is no need
to reset each compressor in a network. The control
will automatically synchronize the network clocks.
Section VIII - Power$ync II
The control will now move to the Set Date Menu.
PRESS F1
PRESS F2
00:00
00/00/00
From Compressor Maintenance Menu 1, press the UP
PRESS F3
arrow key to move the display to Compressor
Maintenance Menu 2. This menu allows the operator to
test the lift valve system or to check various control
settings.
00:00
Quincy Compressor
SET DATE MENU
CURRENT DATE
PRESS ENTER TO ACCEPT VALUE
Follow the same procedure used to change the
time. When the correct date has been entered or
confirmed, the display will ask for the day of the
week.
SET DAY MENU
CURRENT DAY
PRESS ENTER TO ACCEPT VALUE
The current setting for the day of the week will be
flashing. If it is incorrect, use the UP or DOWN
arrow key until the correct day of the week is
shown. Then press ENTER to accept. The display
will indicate that the control is transferring the
updated date and day information to the other
compressors on the network.
COMPRESSOR MAINTENANCE MENU 2
COMPRESSOR CONTROL TEST
COMPRESSOR INFORMATION
UP FOR NEXT MENU/DOWN FOR PREVIOUS MENU
To test the operation of the Power$ync II
press F1. To move to another maintenance menu,
use the UP or DOWN arrow keys.
®
- QSD™
Operation
00/00/00
MONDAY
PRESS F1
PRESS F2
®
valves,
53

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qsd series

Table of Contents