Added Drive Reported As Defective; Error Message On Screen; Expansion Cards Or Onboard Devices Not Recognized - Fujitsu PRIMERGY TX200 S7 Operating Manual

Hide thumbs Also See for PRIMERGY TX200 S7:
Table of Contents

Advertisement

8.9

Added drive reported as defective

RAID controller is not configured for this drive
The drive was probably installed when the system was switched off.
Ê Reconfigure the RAID controller for the drive using the corresponding utility.
Information is provided in the documentation for the RAID controller.
or
Ê Remove and reinstall the drive while the system is switched ON.
If the hard disk drive continues to be shown as defective, then replace it (see
the "PRIMERGY TX150 S8 / TX200 S7 Server Upgrade and Maintenance
Manual").
I
Further information is provided in the "Integrated RAID for SAS User's
Guide" (on the ServerView Suite DVD 2 under Industry Standard Servers -
Expansion Cards - Storage Adapters - LSI RAID / SCSI Controllers) or in the
"Modular RAID Controller Installation Guide" (on the ServerView Suite
DVD 2 under Industry Standard Servers - Expansion Cards - Storage Adapters
- LSI RAID / SCSI Controllers).
For more information on configuring the controller, see section
"Configuring the server" on page
8.10

Error message on screen

The meaning of the error message is explained in the documentation for the
relevant components and programs on the ServerView Suite DVD 2.
8.11
Expansion cards or onboard devices not
recognized
When an expansion card is added, other expansion cards or onboard devices
might not be recognized.
Ê Reinstall the drivers for the expansion cards or onboard devices that are not
recognized.
TX200 S7
78.
Operating Manual
Troubleshooting and tips
89