V.

ELECTRICAL INSTALLATION

WARNING: REMOVE POWER FROM THE UNIT BEFORE INSTALLING, REMOVING OR MAKING
ADJUSTMENTS

GENERAL SAFETY

When using electrical equipment, you should always follow basic safety precautions, including the following:
The installation/wiring of this product must comply with all national, federal, state, municipal, and local
codes that apply.
Properly ground the enclosure to an adequate earth ground.
Do not modify any factory wiring. Connections should only be made to the terminals described in this
section.
All connections to the unit must use conductors with an insulation rating of 300 V minimum, rated for
105 C, a minimum flammability rating of VW-1, and be of appropriate gauge for the voltage and current
required (see specs).
Do not allow moisture to enter the electronics enclosure. Conduit should slope downward from the
housing. Install drip loops and seal conduit with silicone rubber product.

DISCONNECT REQUIREMENTS FOR PERMANENTLY INSTALLED EQUIPMENT

A dedicated disconnecting device (circuit breaker) must be provided for the proper installation of the unit. If
independent circuits are used for power input, individual disconnects are required. Disconnects must meet the
following requirements:
Located in close proximity to the device
Easily accessible to the operator
Appropriately marked as the disconnect for the device and associated circuit
Sized appropriately to the requirements of the protected circuit (See Specifications)

RS-485/RS-422 EQUIPMENT MATRIX

DEVICE
Bindicator 3D Level Scanner
Bindicator Mark-4/GP-4 Yo-Yo
Bindicator/Kistler-Morse ORB
Bindicator/Kistler-Morse ORB 4-20mA Input Box
Bindicator SonoTracker
Kislter-Morse Ultrawave
Kistler-Morse MVS
Kistler-Morse STXplus
Kistler-Morse SVS2000
Kistler-Morse Weigh II
Niagara Meters 5600 Controller
Note: RS-485 Communication will be programmed at a baud rate of 115200;
RS-422 Commuication will be programmed at a baud rate of 9600.
COMMUNICATION
RS-485
RS-422
x
x
x
x
x
x
x
x
x
x
x
x
6
www.bindicator.com
WRL180213 Rev. B