Selectable Jumpers; Trimpot Adjustments - Baldor NEMA 1 / IP40 Installation And Operation Manual

Adjustable frequency drive
Table of Contents

Advertisement

1.4 SELECTABLE JUMPERS

Table 1-4 outlines the positions of Selectable Jumpers used to
tailor the control for specific application requirements.
Feature
AC Line Input Voltage
Selection (115/230 Volts AC)
J1. Refer to Section 6.1.
Motor Horsepower (1/8, 1/4,
1/2, 3/4, 1 HP) J2. Refer to
Section 6.2.
Automatic or Manual Start
and Reset. J3. Refer to
Section 6.3.
Motor Frequency (50/60 Hz)
J5. Frequency Multiplier (1X,
2X) J4. Refer to Section 6.4.1
and 6.4.2.
"Run" or "Fault" Output
Relay Operation. J6. Refer to
Section 6.5.

1.5 TRIMPOT ADJUSTMENTS

Table 1-5 outlines the Trimpot Adjustments of the control.
Trimpot
Minimum Speed (MIN). Refer
to Section 7.1.
Maximum Speed (MAX). Refer
to Section 7.2.
Acceleration (ACCEL). Refer
to Section 7.3.
Deceleration (DECEL). Refer
to Section 7.4.
Slip Compensation (COMP).
Refer to Section 7.5.
Current Limit (CL). Refer to
Section 7.6.
Table 1-4 Selectable Jumpers
Factory set for 208/230VAC (Install Jumper
for 115VAC Operation).
Selectable for the motor use.
Factory set for Auto. Can be set for
Automatic start or Manual start (Optional
FSR Switch required).
Factory set for 60 Hz. Must be set for the
motor being used. In addition, the drive
may be set for up to 2X the motor's rated
RPM.
Factory set to RUN position. Set to either
Run or Fault for intended application.
Table 1-5 Trimpot Adjustments
Sets the minimum speed of the motor.
Sets the maximum speed of the motor.
Sets the amount of time for the motor to
accelerate from zero speed to full speed.
Sets the amount of time for the motor to
decelerate from full speed to zero speed.
Sets the amount of Volts/Hz to maintain set
motor speed under varying loads.
Sets the current limit and limits the
maximum current (torque) to the motor.
Description
Description
11