Page 1
Networked DVR 16CH /9CH/4CH NW-STA-5016/5009/5004 NW-STA-5016/5009/5004 USER MANUAL USER MANUAL Networked DVR Product Feature 16/9/4 CH Multiple camera Input Embedded XP O/S of DOM(Disk On Memory) solution Mounted Pentapllex Multi tasking for Monitoring And recording and searching and networking Able to record the CIF size(320*240) video...
• All shipment for repair should be prepaid and properly packed with a note outlining the defect. • Send the product with purchase number or other related documents obtaining from Fore Tech or its agent as proof purchasing the product. Page: NW-STA-5016/5009/5004 User Manual...
4 CH audio recording and two way audio communication. CD, DVD RW, USB external saving devices Ethernet 10/100Mbps, RS-232C network support Maximum 16 ports sensor input and 4 port alarm output X-plex multitasking, recording, playback, backup and network. STATIC, DHCP, PPPOE support Page: NW-STA-5016/5009/5004 User Manual...
Page 5
Firmware upgrade using network and USB port. Remote upgrade using CMS Free alarm (max 30secs), port alarm (max 120secs) recording Watermarking Private backup viewer E-Map’s layout mapping able to install maximum 4 HDD to save 2.5T Page: NW-STA-5016/5009/5004 User Manual...
Page 6
User Manual Chapter 3 General product operation Page: NW-STA-5016/5009/5004 User Manual...
Page 7
Output video through USB port for use the USB memory backup S-VIDEO comport and USB update. 8) AUDIO OUT 9) ETHERNET: Out put audio Port for Cross cable. by 1 port ( Possible to Remote Surveillance.) Page: NW-STA-5016/5009/5004 User Manual...
Page 8
Output video through USB port for use the USB memory backup S-VIDEO comport and USB update. 8) AUDIO OUT 9) ETHERNET: Out put audio Port for Cross cable. by 1 port ( Possible to Remote Surveillance.) Page: NW-STA-5016/5009/5004 User Manual...
Page 9
Output video 7) ETHERNET: through S-VIDEO DC12V Adaptor by IV-STA-5004 : Port for Cross cable comport BNC 4Port ( Possible to Remote (75Ω AUTO) 11) POWER Surveillance.) System Power On/Off 8) RS-232 Connect Port for Program Debug. Page: NW-STA-5016/5009/5004 User Manual...
③ select ‘OK’ button after the message “ system will shutdown”. Press ‘Enter’ button. ④ press the power switch at the back to be ‘Off’. System Login Input password Input the password using number buttons at the password box. ☞ The default value is ‘0000’. Page: NW-STA-5016/5009/5004 User Manual...
Page 11
B : slave hard Remote controller status C : master hard D : slave hard * color icon indications blue : HDD installed. yellow : recording in progress orange : Hard disk is full red : Hard disk error Page: NW-STA-5016/5009/5004 User Manual...
-If you press another channel number that is not being displayed in the current quad screen, it turns another quad screen including the channel you selected. 1 CAM01 2 CAM02 5 CAM05 6 CAM07 3 CAM03 4 CAM04 7 CAM07 8 CAM08 Page: NW-STA-5016/5009/5004 User Manual...
Page 13
POP screen mode *only for 9Ch & 16Ch products -press ‘POP’ button, it will display a certain channel larger than other channels. OSD mode - press ‘OSD’ button, icons and channel status phrases will appear or disappear. OSD button Page: NW-STA-5016/5009/5004 User Manual...
Page 14
(4) you can move the small screen using arrow buttons. Sequence playback screen mode - If you press ‘SEQ’ button, full screen or quad screen will be displayed in sequence. - you can setup duration time at system menu. Page: NW-STA-5016/5009/5004 User Manual...
Page 15
Camera 1 ~ Camera 4 Camera 5 ~ Camera 8 Camera 5 ~ Camera 8 Camera 9 ~ Camera 12 Camera 6 ~ Camera 9 Camera 13~ Camera 16 [IV-STA-5009] [IV-STA-5016] ▷you can setup duration time at system menu. Page: NW-STA-5016/5009/5004 User Manual...
Check before recording !! (1) Check if hard disk is formatted. (2) Check the camera output. (3) Check if each channel names are correct. (4) Set each channel’s recording quality. (5) Set each channel’s recording frames. Page: NW-STA-5016/5009/5004 User Manual...
Page 17
(2) select the date and time using arrow keys. Press ‘Enter’ button. (3) lastly, select ‘OK’ and press ‘Enter button’. SEARCH BY CALENDER 2008/ 2 SU MO TU WE TH FR SA 1011 1718 2008/02/16 13:00 CLOSE Page: NW-STA-5016/5009/5004 User Manual...
Page 18
- Playback by frame during pause. ▶ Playback Playback the recorded screen. ∥ Pause Pause the screen. Fast forward -Fast forward during playback. ▶▶ Frame playback -Playback by frame during pause. ■ stop Stop the playback. Page: NW-STA-5016/5009/5004 User Manual...
Page 19
FORMAT – format the media before backup. CHANNEL – select channels to backup. FROM – input the date/time to start backup. TO – input the date/time to finish backup. (4) Select ‘BACKUP’ and press ‘Enter’ button. NW-STA-5016/5009/5004 User Manual Page:...
Page 20
(3) playback : playback the backup data. (playback, pause, speed playback, playback by frame) (4) division : 1 division, 4 division, 9 division, 16 division (5) watermark : check if there is any modification of data. (6) status box : display the status of backup viewer. Page: NW-STA-5016/5009/5004 User Manual...
Page 21
User Manual Open file (1) Click ‘Open file’ button from the main screen. (2) Select files to playback. (3) After loading backup file is completed, you can playback backup data and save it as bmp files. Page: NW-STA-5016/5009/5004 User Manual...
Page 22
(2) Select and playback the channel, which audio is saved, it playbacks audio data at the same time. Save (1) Save backup data. (2) Select screen division. (3) Click ‘save’ button. (4) Name the ‘Bmp’ file and save. Image of saved bmp file as 9 division screen Page: NW-STA-5016/5009/5004 User Manual...
Page 23
(3) Click playback or speed playback button. (4) It shows the image with error message if there is any modification of data. It shows ‘Ok’ in the status box if there is no modification of data. Page: NW-STA-5016/5009/5004 User Manual...
Page 24
NOTE: you can set ‘Preset’ at System menu. NOTE: you can set ‘Preset’ at System menu. [Menu camera setup preset] [Menu camera setup preset] you can set ‘Scan list’ at System menu. you can set ‘Scan list’ at System menu. [Menu camera setup scan point] [Menu camera setup scan point] Page: NW-STA-5016/5009/5004 User Manual...
2007/08/29 00:00:00 SEARCH CLOSE event type – select types of event to search from – input date/time to start searching to – input date/time to finish searching select ‘Search’ and press ‘Enter’ button to start log search. NW-STA-5016/5009/5004 User Manual Page:...
Page 26
(1) press ‘DVR-ID’ button on the remote-controller. (2) it will beep. Then you can input ‘Remote-controller ID’. (3) press the DVR ID to operate using number buttons. R:01 Not working Remote-controller ID : 02 working R:02 Page: NW-STA-5016/5009/5004 User Manual...
User Manual Chapter 4 System setup Page: NW-STA-5016/5009/5004 User Manual...
Page 28
‘Enter’ button to activate the selected menu or to go to sub menu. press ‘Menu’ button to close system setup or go to the previous menu. LIVE-SEQ(FULL) LIVE-SEQ(FULL) LIVE-SEQ(QUAD) LIVE-SEQ(QUAD) SPOT-SEQ(FULL) SPOT-SEQ(FULL) SPOT-SEQ(QUAD) SPOT-SEQ(QUAD) MISC MISC Page: NW-STA-5016/5009/5004 User Manual...
Page 29
CAMERA - PTZ PROTOCOL BAUD PELCO_D 4800 PELCO_D 4800 PELCO_D 4800 PELCO_D 4800 PELCO_D 4800 PELCO_D 4800 PELCO_D 4800 PELCO_D 4800 9-16 CANCEL 1 ~ 8 9 ~ 16 Press button to move to the next menu page. Page: NW-STA-5016/5009/5004 User Manual...
Page 30
Left margin – adjust the left margin of OSD. Right margin – adjust the right margin of OSD. Top margin – adjust the top margin of OSD. Bottom margin - adjust the bottom margin of OSD. Top margin Left margin Right margin Bottom margin NW-STA-5016/5009/5004 User Manual Page:...
Page 31
Screen display setup – spot sequence scanning (full screen) Setup duration time for spot sequence scanning in full screen. NOTE : can input maximum 99 second. NOTE : can input maximum 99 second. DISPLAY - SPOT-SEQ(FULL) TIME TIME CANCEL Page: NW-STA-5016/5009/5004 User Manual...
Page 32
720X480 or 720X576 resolution. Event popup if any motion/ sensor activity is detected, detected channel will show in full screen. Event Page: NW-STA-5016/5009/5004 User Manual...
Page 33
VIDEO DETECT AUTO DETECT AUTODETECT AUTODETECT SWITCH SWITCH NTSC NTSC SWITCH : detect video signals according to main-board jumper within the product. NTSC : set video signal as NTSC. PAL : set video signal as PAL. Page: NW-STA-5016/5009/5004 User Manual...
ID – input camera IDs. protocol – select the registered protocol. baud – select the registered baud. CAMERA - PTZ PROTOCOL BAUD PELCO_D 4800 PELCO_D 4800 PELCO_D 4800 PELCO_D 4800 PELCO_D 4800 PELCO_D 4800 PELCO_D 4800 PELCO_D 4800 9-16 CANCEL NW-STA-5016/5009/5004 User Manual Page:...
Page 35
– clear all the setup values. (1) Select camera. (2) Select ‘Set’ button. (3) Then the channel turns PTZ mode. (4) Move the camera to get the position you want. (5) Press ‘Enter’ button to save the preset. PTZ-CH1 NW-STA-5016/5009/5004 User Manual Page:...
Page 36
– clear all setup values. CAMERA – SCAN POINT CAMERA LIST PRESET PRESET PTZ01 PTZ09 PTZ04 PTZ25 CLEAR ALL CANCEL Camera 1 will move following the path as below. PTZ01 3sec PTZ09 3sec PTZ04 3sec PTZ25 3sec PTZ01 …….. NW-STA-5016/5009/5004 User Manual Page:...
Page 37
DEFAULT CANCEL Camera setup – adjusting position camera – select a camera right/left – move the camera to right and left. default value – set it as default value. CAMERA - POSITION CAMERA LEFT/RIGHT DEFAULT CANCEL NW-STA-5016/5009/5004 User Manual Page:...
– set recording quality for each channel. Recording quality Display quality HDD capacity needed Basic Small Normal Normal Medium High Good Large best Very good Very large Frame rate set frame rate for each channel. NW-STA-5016/5009/5004 User Manual Page:...
Page 39
(2) Select day/time to record and press ‘Enter’ button. (3) it shifts to different type as you press ‘Enter’ button. RECORD - SCHEDULE ALL 0 SU C C C C C E E E E C: Continuous E: Event CHANNEL CANCEL Page: NW-STA-5016/5009/5004 User Manual...
Page 40
– automatically delete data after set date. continuous record – you cannot stop recording while it is in process as it continuously records. watermark – activate watermarking function. RECORD MISC OVERWRITE AUTO-DELETE DAYS (0-99) CONTINUE REC WATER-MARK CANCEL Page: NW-STA-5016/5009/5004 User Manual...
(3) off – do not detect motion. sensitivity – select level of motion sensitivity. level of sensitivity : 0 < 1 < 2 < ….. <9 Alarm out – set to activate alarm system when any motion is detected. Page: NW-STA-5016/5009/5004 User Manual...
Page 42
– activate buzzer when the event occurs. alarm out time – set duration time to operate alarm system. EVENT - ALARM PRE-REC TIME SEC (0-30) POST-REC TIME SEC (0-120) BUZZER OUT TIME SEC (0-120) CANCEL Page: NW-STA-5016/5009/5004 User Manual...
Page 43
SHOW: show saved file info of HDD of connected USB type. STORAGE – HDD FORMAT TYPE ▼ USB-1 /dev/sda FORMAT SHOW ▼ USB-2 /dev/sdb FORMAT SHOW ▼ USB-3 NONE FORMAT SHOW ▼ USB-4 NONE FORMAT SHOW CANCEL Page: NW-STA-5016/5009/5004 User Manual...
Page 44
00:0E:00:00:00:00 PPPOR ID PASSWORD **** CANCEL PPPOE – ADSL only, input registered ID and password. NETWORK - SETUP TYPE ADSL(PPPOE) IP ADDRESS 192.168.000.138 GATEWAY 192.168.000.001 NET MASK 255.255.255.000 MAC ADDRESS 00:0E:00:00:00:00 PPPOR ID PASSWORD **** CANCEL NW-STA-5016/5009/5004 User Manual Page:...
Page 45
– select web port to connect to web browser. bandwidth - limit transmitting data capacity through the network. DVR-ID - input DVR name to connect CMS S/W. NETWORK - CLIENT PASSWORD **** CLIENT PORT 7620 - 7624 WEB-PORT 0080 BANDWIDTH UNLIMITED DVR-ID CANCEL Page: NW-STA-5016/5009/5004 User Manual...
Page 46
IP addresses, do not register any IP. User you can add user’s ID and password for network connection. NETWORK – ACCESS LIST USER-ID PASSWORD NET-ID 1 **** NET-ID 2 **** NET-ID 3 **** NET-ID 4 **** CANCEL Page: NW-STA-5016/5009/5004 User Manual...
Page 47
PORT – input connection port of CAMS CC. (default value: 6500) CMM IP – input connection info of CAMS CMM. PORT – input connection port of CAMS CMM. (default value:7600) NETWORK – SERVER CC IP 192.168.000.131 PORT 6500 CMM IP 192.168.000.131 PORT 7600 CANCEL Page: NW-STA-5016/5009/5004 User Manual...
Page 48
Save configuration – save the values set in the current menu. SYSTEM - CONFIG SAVE CONFIG LOAD CONFIG SAVE CONFIG Device /dev/ sda DEFAULT FILE NAME config_16_00.cfg CANCEL CANCEL Default value – set it as default value. NW-STA-5016/5009/5004 User Manual Page:...
Page 49
Time zone – select the time different from standard time of time-server. Summer time set summer time period. (1) starting time : input starting date/time of summer time. (2) ending time : input ending date/time of summer time. Page: NW-STA-5016/5009/5004 User Manual...
Page 50
– set whether to input user password or not when it starts/ends recording. search check – set whether to input user password or not when searching record. backup check – set whether to input user password or not when backup. Page: NW-STA-5016/5009/5004 User Manual...
Page 51
KEYBOARD – control the system using keyboard contoller. Key-tone – set buzzer sound on/off for pressing button. Audio – set audio output on/off. System – System shutdown Select ‘’System shutdown’. If you see the message “system will shutdown”, you can shutdown system. Page: NW-STA-5016/5009/5004 User Manual...
/dev/sda File List flash-gui16-ft_16-080 CANCEL (6) Device – select USB device with firmware file. (7) File list – select the right firmware file. (8) Select ‘OK’. System automatically upgrades. System will reboot after upgrade is completed. Page: NW-STA-5016/5009/5004 User Manual...
(4) Select ‘Server IP’ with firmware file and file name. then select ‘OK’. (5) You can manually input server IP and file name if the system appointed server IP and file name is different. (6) System will automatically reboot after upgrade is completed. Page: NW-STA-5016/5009/5004 User Manual...
Some states/countries do not allow the exclusion or limitation of liability for consequential or incidental damages so the above limitation may not apply to you. Page: NW-STA-5016/5009/5004 User Manual...
User Manual1200 Standalone DVR/GUI Standalone DVR/GUI USER MANUAL USER MANUAL 12000 Ford Rd, Suite 110, Dallas, TX 75234 Tel: 972-247-1203 Fax: 972-247-1291 www.idview.com Page: NW-STA-5016/5009/5004 User Manual...
Need help?
Do you have a question about the NW-STA-5016 and is the answer not in the manual?
Questions and answers