1
Before you begin installing the fan, Switch power off
at Service panel and lock service disconnecting
means to prevent power from being switched on ac-
cidentally. When the service disconnecting means
cannot be locked, securely fasten a prominent warn-
ing device, such as a tag, to the service panel.
Remove the 6 screws attaching the Mounting
neck the mounting plate. Retain the 6 screws
for re-assembly.
7
Lift mounting neck to mounting Plate and align
screws.
© 2011 Monte Carlo Fan Company
2
Warning-Risk of fire, electric shock, or personal
injury. The fan in this box may be either directly
supported from a structural framing member of
a building and/or may be mounted to an outlet
box marked acceptable for fan support of of
31.8kg (70 lbs) or less. Most outlet boxes com-
monly used for the support of lumminaires may
not be acceptable for fan support and may need
to be replaced. Consult a qualified electrician if
in doubt.
5
BUILDING STRUCTURE METHOD
Outlet box
Mounting
Plate
Wood
Screws
Secure mounting plate directly to a joist from
the buliding structure via the two knock out
holes on the outlet box. Use only the appropri-
ate wood screws and washers included with
your fan. Caution: Wood screws must go
through into the building joist.
8
Secure mounting neck to the mounting plate
with 6 screws to become a complete mounting
bracket.
3
3
Remove Safety bar from mounting bracket by
loosing screws, sliding bar to side, and lifting it
off the 2 screws.
6
FAN BRACE AND BOX METHOD
Install the mounting Plate to approved fan
brace and box combination use only the hard-
ware provided with the fan brace and box.
9
Remove the keeper pin and cross pin.