12 Device Information

1
Type and order code
2
Design
2.1
Model
2.2
Degree of protection according to EN 60 529
2.3
Installation Location
3
Performance data
3.1
Operating temperature limits:
Heating water flow
Brine (heat source)
Antifreeze
Minimum brine concentration (-13 °C freezing temperature)
3.2
Temperature spread of heating water (flow/return flow)
Heat output / COP
3.3
Sound power level
3.4
Heating water flow with an internal pressure differential of m³/h / Pa
3.5
Free compression of heat circulating pump (level 3)
3.6
Brine throughput with an internal pressure differential
(heat source) of
3.7
Free compression of brine circulating pump (level 3)
3.8
Refrigerant; total filling weight
4
Dimensions, connections and weight
4.1
Device dimensions without connections
4.2
Device connections to heating system
4.3
Device connections to heat source
4.4
Weight of the transportable unit(s) incl. packing
5
Electrical connection
5.1
Nominal voltage; fuse protection
5.2
Nominal power consumption
5.3
Starting current with soft starter
Nominal current B0 W35 / cos ϕ
5.4
6
Complies with the European safety regulations
7
Additional model features
7.1
Water in device protected against freezing
7.2
Performance levels
7.3
Controller internal/external
1. This data indicates the size and capacity of the system. For an analysis of the economic and energy efficiency of the system, both the bivalence point and the regulation should
also be taken into consideration. The specified values, e.g. B10 / W55, have the following meaning: Heat source temperature 10 °C and heating water flow temperature 55 °C.
2. Note that additional space is required for pipe connections, operation and maintenance.
3. See CE declaration of conformity
4. The heat circulating pump and the heat pump controller must always be ready for operation.
E-8
°C
°C
at B0 / W35
K
1
at B-5 / W55
kW / ---
1
at B0 / W45
kW / ---
1
at B0 / W50
kW / ---
1
at B0 / W35
kW / ---
dB(A)
Pa
m³/h / Pa
Pa
type / kg
2
H x W x L mm
Inch
Inch
kg
V / A
1
B0 W35
kW
A
A / ---
4
SIK 7TE
SIK 9TE
Compact
Compact
IP 20
IP 20
Indoors
Indoors
Up to 58
Up to 58
-5 to +25
-5 to +25
Monoethylene
Monoethylene
glycol
glycol
25%
25%
9.9
5.0
10.5
5.0
5.6 /
7.7 /
2.2
2.3
6.6 /
8.7 /
3.0
3.2
6.7 /
9.0 /
2.9
3.1
6.9 /
6.8 /
9.2 /
9.0 /
4.3
4.1
4.4
4.2
51
51
0.6 /
1.2 /
0.75 /
1.6 /
2500
11600
4500
20500
47500
30400
43500
18500
1.7 /
1.6 /
2.3 /
2.2 /
10000
9300
16000
15000
55000
56200
44000
46000
R407C / 1.5
R407C / 1.8
1115 × 652 × 688 1115 × 652 × 688 1115 × 652 × 688 1115 × 652 × 688
R 1¼" external
R 1¼" external
R 1¼" external
R 1¼" external
179
180
400 / 16
400 / 16
1.6
1.66
2.07
2.14
30 (without SS)
15
2,89 /
3 /
3,77 /
3,86 /
0,8
0,8
0,8
0,8
3
3
Yes
Yes
1
1
Internal
Internal
SIK 11TE
SIK 14TE
Compact
Compact
IP 20
IP 20
Indoors
Indoors
Up to 58
Up to 58
-5 to +25
-5 to +25
Monoethylene
Monoethylene
glycol
glycol
25%
25%
10.1
5.0
9.6
5.0
9.4 /
12.5 /
2.4
2.6
11.2 /
14.1 /
3.2
3.5
11.3 /
14.2 /
3.0
3.4
11.8 /
11.7 /
14.5 /
14.4 /
4.4
4.2
4.5
4.3
51
51
1.0 /
2.0 /
1.3 /
2.5 /
3500
14800
3500
16500
65500
48200
64500
42500
3.0 /
2.7 /
3.5 /
3.3 /
13000
11400
13000
11600
40000
44600
34000
38400
R407C / 2.0
R407C / 2.3
R 1¼" external
R 1¼" external
R 1¼" external
R 1¼" external
191
203
400 / 16
400 / 16
2.66
2.79
3.22
3.37
26
26
4,84 /
5,03 /
5,81 /
6,08 /
0,8
0,8
0,8
0,8
3
3
Yes
Yes
1
1
Internal
Internal

Advertisement

loading

This manual is also suitable for:

Sik 11 meSik 16 meSikh 6 teSikh 9 te