Sharp R-380D Service Manual page 20

Microwave oven
Hide thumbs Also See for R-380D:
Table of Contents

Advertisement

R-380D
Pin No.
Signal
I/O
24
P25
OUT
25-26
P26-P27
OUT
27-29
P30-P32
OUT
30-34
P33-P37
OUT
35
CVCC
IN
36
VSS
IN
37-38
V3-V2
IN
39-40
V1-V0
IN
41
VCC
IN
42-45
OUT
COM4-COM1
46-65
OUT
SEG1-SEG20
66-79
P74-P91
OUT
80-85
OUT
SEG35-SEG40
86
P40
OUT
87
P41
IN
88
P42
IN
89
IRQ0
IN
90
AVCC
IN
91
AN0
IN
92
AN1
IN
93
AN2
IN
94
AN3
IN
95-98
AN4-AN7
IN
99
AN8
IN
100
AN9
IN
Magnetron high-voltage circuit driving signal.
To turn on and off the cook relay (RY2). The
signals holds "L" level during microwave cooking
and "H" level while not cooking. In other cooking
modes (variable cooking) the signal turns to "H"
level and "L" level in repetition according to the
power level.
Terminal not used.
Terminal not used.
Used for initial balancing of the bridge circuit (absolute humidity sensor).
Connected to GND.
Power source voltage: -5.0V.
The power source voltage to the LSI is input to VSS terminal. Connected to VC.
Terminal not used.
Power source voltage input terminal.
Standard voltage for LCD. Connected to GND.
Power source voltage: GND (0V).
The power source voltage to drive the LSI is input to VCC terminal.
Terminal not used.
Terminal not used.
Data output terminal to LCD driver IC3.
Terminal not used.
Terminal not used.
Signal similar to AN10.
When either G13 line on key matrix is touched, a corresponding signal will be input into
P41.
Signal similar to AN10.
When either G12 line on key matrix is touched, a corresponding signal will be input into
P42.
Signal synchronized with commercial power source frequency.
This is the basic timing for time processing of LSI.
A/D converter power source voltage.
The power source voltage to drive the A/D converter in the LSI. Connected to GND.
Used for initial balancing of the bridge circuit (absolute humidity sensor). This input is an
analog input terminal from the AH sensor circuit, and connected to the A/D converter built
into the LSI.
AH sensor input.
This input is an analog input terminal from the AH sensor circuit, and connected to the
A/D converter built into the LSI.
To input signal which communicates the door open/close information to LSI.
Door close "H" level signal (0V). Door open "L" level signal (-5V).
Connected to VC through resistor.
Terminal to change cooking input according to the Model.
By using the A/D converter contained in the LSI, DC voltage in accordance with the Model
in operation is applied to set up its cooking constant.
Input terminal to judge the model.
The signal out of P14 will be input into AN8 through G4 line on key matrix. The LSI will
judge the model by this signal.
Signal similar to AN10.
When either G11 line on key matrix is touched, a corresponding signal will be input into
AN9.
Description
HIGH
M.HIGH
(ON and OFF times for other power level.)
18
OFF
H : GND
ON
L : -5V
OFF
OFF
H : GND
24 sec.
8 sec.
ON
L : -5V
H : GND
L : -5V
20.0 msec.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents