Control Panel

Clean Filter indicator light
2
Filter
Filter
Bucket
Full
Full
indicator
light
Cont.
Cont.
On
1
Timer
7
Continuous operation
Timer ON/OFF
ON indicator light
indicator light
1
Continuous Operation
Press to activate for continuous
dehumidifer operation.
2
Filter
The clean filter indicator light will
come on after 250 hours of operation.
After cleaning and replacing the filter,
push "Filter" to reset and the light will
go off.
3
Fan
Press to select either High or Normal
fan speed. Set to High for maximum
moisture removal. When humidity has
been reduced (or quieter operation is
preferred) set to Normal.
4
Power ON/OFF
NOTE: The Control Panel on the unit you purchased may be slightly different than shown.
High Fan indicator light
Turbo
Fan
8
3
Normal
Normal Fan
indicator light
Auto defrost
Off
4
6
5
Auto defrost ON
indicator light
5
7
Adjustment Keys
• SET HUMIDITY: From 35% to 85% RH
(Relative Humity) in 5% increments.
For drier air, press " – " to set a lower
percent value. For damper air press
" + " to set a higher percent value.
• SET TIMER: Set Auto Start and Auto
Stop values from 0.0 to 24.
6
Timer
Press to initiate the Auto Start and
Auto Stop feature. Use the " – " and
" + " keys to set values.
8
Digital Display
Shows humidity levels (35-80%) or
timer settings (00-24) while setting.
Also displays actual room humidity
levels (30-90% Relative Humidity)
during operation (±5% accuracy).
4

OTHER FEATURES

• Tank Full Light: Glows when tank is full,
removed or positioned incorrectly.
• Auto Shut Off: Dehumidifier shuts off after
30 seconds when the water tank is full,
missing or positioned incorrectly. Also, the
unit will shut off automatically when desired
humidity setting is reached (on some models
the fan motor may continue running).
• 3 Minute Delay: After the unit is stopped,
it will not resume operation until 3 minutes
have passed to protect internal components.
SETTING THE TIMER
1. If power is ON, press the "Timer" key and the "Timer Off" indicator light illuminates. This
indicates that the Auto Stop program is initiated. Press the "Timer" key again to initiate
the Auto Start program. If power is OFF, press the "Timer" key and the "Timer On" indicator
light illuminates. This indicates that the Auto Start program is initiated. Press the "Timer" key
again to intiate the Auto Stop program.
2. Press the
10 hours, then at 1 hour increments up to 24 hours. The control will count down the time
remaining until start. The selected time will register for 5 seconds and the system will
automatically revert back to displaying the previous humidity setting.
3. When the Auto Start and Auto Stop times are set within the same program sequence, the
"timer on" and "timer off" indicator lights illuminate to identify that both ON and OFF times
are now programmed.
4. Turning the unit ON or OFF at any time or adjusting the timer setting to 0.0 will cancel
the Auto Start and Auto Stop functions. When display window shows "P2" these functions
will also be cancelled.
6
ERROR/PROTECTION CODES
AS – Humidity sensor error. Unplug unit and plug back in. If error repeats, call for service.
ES – Temperature sensor error. Unplug unit and plug back in. If error repeats, call for service.
P2 – Water tank is full or in wrong position. Empty tank and replace correctly.
EC – Unit malfunction. Check to make sure working environment is between 41ºF/5ºC and
95ºF/35ºC. If so, and error repeats, call for service.
• Check Filter Light: The system begins
counting the time when the fan motor
switches on. At 250+ hours of operation,
the "Filter" light flashes once per second
to indicate air filter clearning is necessary.
After cleaning and replacing the filter, press
the "Filter" key and the light will go off.
• Auto Restart: If the unit stops due to a
power outage, it will automatically resume
operation at current settings when power
is restored.
(NOTE: Timer can be set with unit Power ON or OFF)
or
keys to adjust times up or down in increments of 0.5 hour up to
5
Control Panel