Lenovo ThinkCentre 3231 Hardware Maintenance Manual page 63

Hide thumbs Also See for ThinkCentre 3231:
Table of Contents

Advertisement

Diagnostic Error Code
001-040-XXX
System IRQ failure
001-041-XXX
System DMA failure
001-195-XXX
System Test aborted by user
001-196-XXX
System test halt, error threshold exceeded
001-197-XXX
System test warning
001-198-XXX
System test aborted
001-199-XXX
System test failed, cause unknown
001-250-XXX
System ECC error
001-254-XXX
001-255-XXX
001-256-XXX
001-257-XXX
System DMA error
001-260-XXX
001-264-XXX
System IRQ error
001-268-XXX
System IRQ1 failure
001-269-XXX
System IRQ2 failure
001-270-XXX
System IRQ3 failure
FRU/Action
1. Power-off/on system and re-test
2. System board
1. Power-off/on system and re-test
2. System board
Information only
Re-start the test, if necessary
1. Press F3 to review the log file
2. Re-start the test to reset the log file
1. Make sure the component that is called
out is connected and/or enabled. See
Chapter 6, "Using the Setup Utility," on
page 49
2. Re-run test
3. Replace the component that is called out
in warning statement
4. Replace the component under test
1. If a component is called out, make sure
it is connected and/or enabled. See
Chapter 6, "Using the Setup Utility," on
page 49
2. Flash the system and retest. See
"Updating (flashing) BIOS from a disc"
on page 746
3. Go to "Undetermined problems" on page
80
1. Go to "Undetermined problems" on page
80
2. Flash the system and re-test
3. Replace component under function test
System board
System board
System board
1. Device on IRQ1
2. System board
1. Device on IRQ2
2. System board
1. Device on IRQ3
2. System board
Chapter 7. Symptom-to-FRU index
57

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents