The Keystone "B" Vent Zero Clearance Gas
Fireplace
Installer: Leave these instructions with the consumer.
Consumer: Retain these instructions for future use.
WARNING: If the information in this manual is not
followed exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS
● Do not try to light any appliance.
● Do not touch any electrical switch; do not use any
phone in your building.
● Immediately call your gas supplier from a neighbors
phone. Follow the gas supplier's instructions.
● If you cannot reach your gas supplier, call the fire
department.
- Installation and service must be performed by
a qualified installer, service agency, or the gas
supplier.
19400-3-0406

INSTALLATION INSTRUCTIONS

OWNER'S MANUAL
GAS-FIRED
AND
B-VENT
GAS FIREPLACE
MODEL SERIES
MILLIVOLT
BVD34FP30(F,L)N-1
BVD36FP32(F,L)N-1
BVP42FP32(F,L)N-1
DIRECT IGNITION
BVD34FP50(F,L)N-1
BVD36FP52(F,L)N-1
BVP42FP52(F,L)N-1
EFFECTIVE DATE
APRIL 2006
UL FILE NO. MH45034
NOT INTENDED FOR USE AS A PRIMARY HEAT
SOURCE. This appliance is tested and approved as
either supplemental room heat or as a decorative
appliance. It should not be factored as primary heat
in residential heating calculations.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certified
kit is used.
WARNING: If not installed, operated and maintained
in accordance with the manufacturer's instructions,
this product could expose you to substances in fuel or
from fuel combustion which can cause death or seri-
ous illness.
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BVD34FP30FN-1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for White Mountain BVD34FP30FN-1

  • Page 1: Installation Instructions

    INSTALLATION INSTRUCTIONS OWNER’S MANUAL The Keystone "B" Vent Zero Clearance Gas B-VENT Fireplace GAS FIREPLACE MODEL SERIES MILLIVOLT BVD34FP30(F,L)N-1 BVD36FP32(F,L)N-1 BVP42FP32(F,L)N-1 DIRECT IGNITION BVD34FP50(F,L)N-1 BVD36FP52(F,L)N-1 GAS-FIRED BVP42FP52(F,L)N-1 EFFECTIVE DATE APRIL 2006 UL FILE NO. MH45034 Installer: Leave these instructions with the consumer. Consumer: Retain these instructions for future use.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Section Important Safety Information ....................3 Safety Information for Users of LP Gas ..................4 Introduction ..........................5 Specifications ..........................6 Fireplace Dimensions ........................6 Clearances . Locating Fireplace ........................7 Gas Supply ..........................8-9 Installation .........................10-11 Venting ..........................12-13 Log Placement (BVD34 and BVD36) (5 Log Set) ..............14 Log Placement (BVP42) (3 Log Set) ..................15 Operating Instructions ......................16-17 Standing Pilot Wiring Diagram ....................18...
  • Page 3: Important Safety Information

    IMPORTANT SAFETY INFORMATION Before enclosing the vent pipe assembly, operate the appliance to ensure it is venting properly. • If this appliance is installed directly on carpeting, • Clothing or other flammable material should not be tile or other combustible material other than wood placed on or near the appliance.
  • Page 4: Safety Information For Users Of Lp Gas

    SAFETY INFORMATION FOR USERS OF LP GAS Propane (LP-Gas) is a flammable gas which can cause fires them point by point with the members of your household. and explosions. In its natural state, propane is odorless Someday when there may not be a minute to lose, everyone’s and colorless.
  • Page 5: Introduction

    INTRODUCTION Instructions to Installer Any alteration of the original design, installed other than 1. Installer must leave instruction manual with owner after as shown in these instructions or use with a type of gas not installation. shown on the rating plate is the responsibility of the person 2.
  • Page 6: Specifications

    SPECIFICATIONS BVD34FP BVD36FP BVP42FP Input Btu/hr Maximum 21,000 25,000 30,000 NOTE: Air shutter KWH (Maximum) settings are factory B-Vent Size 4" Diameter 6" Diameter 6" Diameter minimum settings. Some NAT. (Standard) venting configurations #44 (.086) #42 (.0935) #37 (.104) may require minor air Orifice P-252 P-286...
  • Page 7: Clearances

    CLEARANCES Mantel Chart (Figure 3) Clearance to Combustibles 12” (305mm) Back 0" (0 mm) 10” (254mm) Side 0" (0 mm) Floor 0" (0 mm) MANTEL Top Stand-off 0" (0 mm) Top Framing Edge 1" (25mm) COMBUSTIBLE TRIM AND MANTELS 8” ALLOWED IN SHADED AREA 6”...
  • Page 8: Gas Supply

    GAS SUPPLY The gas pipeline can be brought in through the right or left side of Installing a New Main Gas Cock the appliance. Consult the current National Fuel Gas Code, ANSI Each appliance should have its own manual gas cock. Z223.1 CAN/CGA-B149 (.1 or .2) installation code.
  • Page 9 GAS SUPPLY (CONT) Checking Manifold Pressures Both Propane and Natural gas valves have a built-in pressure regulator in the gas valve. Natural gas models will have a manifold pressure of approximately 3.5" w.c. (.871kPa) at the valve outlet with the inlet pressure to the valve from a minimum of 4.5" w.c. (1.120kPa) for the purpose of input adjustment to a maximum of 14.0"...
  • Page 10: Installation

    INSTALLATION Install the Fresh Air Kit - BVA1 Framing and Finishing A fresh air kit is available as an optional feature with this appliance. 1. Choose unit location. The fresh air kit helps to decrease the amount of room air taken by 2.
  • Page 11: Installation

    INSTALLATION (CONT) Combustible Surround Installation MANTELSHELF COMBUSTIBLE SURROUND FINISHED WALL 2 X 4 HEADER FRONT TRIM OR NON-COMBUSTIBLE MATERIAL MAY OVERLAP BLACK PAINTED STAND OFF FACE (INSTALLATION IS OPTIONAL) JOINT BETWEEN FINISHED WALL AND UNIT SEALED WITH 300° F 149 °...
  • Page 12: Venting

    VENTING Vent Runs Note that for steep roof pitches, the vent height must be increased. In planning the installation for the fireplace, it is necessary to install In high wind conditions, nearby trees, adjoining roof lines, steep certain components before the appliance is completely positioned pitched roofs, and other similar factors can result in poor draft, and installed.
  • Page 13 VENTING (CONT) Vent Size Offset Venting - With Elbows Model BVD34FP series uses a 4" B-Vent for operation. Maximum horizontal Models BVD36FP and BVP42FP series use a 6" B-Vent for distance is 50% of vertical vent height operation. Never downsize venting diameters. Clearances Vent clearances are per vent manufacturer's specifications Vent Configuration...
  • Page 14: Log Placement (Bvd34 And Bvd36) (5 Log Set)

    LOG PLACEMENT (5 LOG SET) Before you begin: if you are installing logs into the BVD34 or BVD36 model, then this fireplace is supplied with a set of five ceramic fiber logs. Do not handle these logs with your bare hands! Always wear gloves to prevent skin irritation from ceramic fibers.
  • Page 15: Log Placement (Bvp42) (3 Log Set)

    LOG PLACEMENT (3 LOG SET) Before you begin: If you are installing logs into the BVP42 model then this fireplace is supplied with a set of three ceramic fiber logs. Do not handle these logs with your bare hands. Always wear gloves to prevent skin irritation from ceramic fibers.
  • Page 16: Operating Instructions

    OPERATING INSTRUCTIONS 750 Millivolt System The OWNER should carefully read and follow these operating The standing pilot (750 millivolt system) is a continuous burning instructions at all times. Lower the door assembly to view the gas pilot. The pilot remains ON even when the main burner is OFF. controls for the fireplace.
  • Page 17: Operating Instructions

    OPERATING INSTRUCTIONS (CONT) Electric (120 volt) Operated Remote Control, FREC STANDING PILOT OPERATING INSTRUCTIONS The fireplace is equipped with a 15 foot length of wire that can CAUTION: Disconnect all electrical supply to the fireplace be used to connect the valve to a wall switch (installer provided) prior to installing the remote control optional equipment.
  • Page 18: Standing Pilot Wiring Diagram

    STANDING PILOT WIRING DIAGRAM (OPTIONAL) REMOTE CONTROL RECEIVER (FACULTATIVE) CONTROLE E DISTANCE DU RECEPTEUR WALL SWITCH INTERRUPTEUR MURAL LIMIT SWITCH THERMOPILE GAS VALVE (OPTIONAL) THERMOSTAT PILOT (FACULATIVE) THERMOSTAT VEILLEUSE WALL SWITCH/REMOTE CONTROL RECEIVER/ THERMOSTAT CONTROLE E DISTANCE DU RECEPTEUR GAS VALVE VALVE DE GAZ Figure 23 Page 18...
  • Page 19: Standing Pilot Lighting Instructions

    STANDING PILOT LIGHTING INSTRUCTIONS FOR YOUR SAFETY, READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE A. This appliance has a pilot which must be lighted by hand. •...
  • Page 20: Standing Pilot Troubleshooting

    STANDING PILOT TROUBLESHOOTING With proper installation and maintenance, your new Gas Fireplace will provide years of trouble-free service. If you do experi- ence a problem, refer to the Trouble Shooting Guide below. This guide will assist a qualified service person in the diagnosis of problems and the corrective action to be taken.
  • Page 21: Standing Pilot Propane/Lp Gas Conversion

    STANDING PILOT PROPANE/LP GAS CONVERSION PARTS LIST "B-VENT" FIREPLACES Conversion Kit BVCK34P BVCK36P BVCK42P Model Conversion Kit Model Model (Part Number) Part Kit No. 19160 Kit No. 19161 Kit No. 19162 Quantity BVD34FP3 SERIES BVCK34P (19160) Description Supplied BVD36FP3 SERIES BVCK36P (19161) Fireplace BVD34FP3...
  • Page 22 BURNER ORIFICE CONVERSION - Slope style burners The burner flame and pilot flame must be checked for proper 8b. On model BVP42FP3 series fireplaces, you will have a flame characteristics, as outlined in this manual. rectangular slope style burner. To gain access to the main V E R I F Y I N G I N P U T R AT E O F C O N V E R T E D orifice, disconnect the gas supply tubing at the air shutter.
  • Page 23: Direct Ignition Wiring Diagram

    DIRECT IGNITION WIRING DIAGRAM GAS VALVE SPARK IGNITOR VALVE DE GAZ (OPTIONAL) WALL SWITCH ÉTINCELLE ALLUMER INTERRUPTEUR MURAL (FACULTATIVE) CONTROL MODULE (OPTIONAL) REMOTE CONTROL AUTORITÉ MODULE RECEIVER 120V (FACULATIVE) CONTROLE E DISTANCE DU RECEPTEUR 120 VAC LINE BLACK NOIR 120 VAC RTN BLACK NOIR WHITE BLANC LIMIT SWITCH...
  • Page 24: Direct Ignition Lighting Instructions

    DIRECT IGNITION LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE. A. BEFORE LIGHTING smell all around the appliance area for •...
  • Page 25: Direct Ignition Troubleshooting

    DIRECT IGNITION TROUBLESHOOTING With proper installation and maintenance, your new Gas Fireplace will provide years of trouble-free service. If you do experience a problem, refer to the troubleshooting guide below. This guide will assist a qualified service person in the diagnosis of problems and the corrective action to be taken.
  • Page 26: Direct Ignition Propane/Lp Gas Conversion

    DIRECT IGNITION PROPANE/LP GAS CONVERSION 1. Turn off the gas supply. 18. Loosen screw and attach a manometer or pressure gauge to 2. Turn off the electrical supply to the appliance if so the outlet pressure tap of the control valve. equipped.
  • Page 27: Maintenance And Service

    MAINTENANCE AND SERVICE PLEASE NOTE It is normal for appliances fabricated of steel to give off some expansion and/or contraction noise during the start up or cool down cycle. Similar noises are found with your furnace heat exchanger or car engine. It is not unusual for your gas fireplace to give off some odor the first time it is burned.
  • Page 28: Bvd34 And Bvd36 Parts List

    BVD34 & BVD36 PARTS LIST INDEX PART NUMBER DESCRIPTION BVD34L BVD34F BVD36L BVD36F 19506 19506 19507 19507 TOP SHIELD 17301 17301 17301 17301 TOP STANDOFF (2 REQUIRED) 10554 10554 10554 10554 NAILING FLANGE (4 REQUIRED) M163 M163 M178 M178 FLUE OUTLET GASKET 19387 19387 19422...
  • Page 29: Bvd34 And Bvd36 Parts View

    BVD34 & BVD36 PARTS VIEW MILLIVOLT BURNER ASSEMBLY DIRECT IGNITION BURNER ASSEMBLY 5 PIECE LOG ASSEMBLY 19400-3-0406 Page 29...
  • Page 30: Bvp42 Parts List

    BVP42 PARTS LIST INDEX NO. PART NUMBER PART NUMBER DESCRIPTION BVP42L BVP42F 19508 19508 TOP SHIELD 17247 17247 TOP STANDOFF (2 REQUIRED) 10554 10554 NAILING FLANGE (4 REQUIRED) M178 M178 FLUE OUTLET GASKET 19422 19422 FLUE OUTLET ASSEMBLY 19398 19398 DOWNDRAFT BAFFLE 19467 19467...
  • Page 31: Bvp42 Parts View

    BVP42 PARTS VIEW MILLIVOLT BURNER ASSEMBLY DIRECT IGNITION BURNER ASSEMBLY 3 PIECE LOG ASSEMBLY 19400-3-0406 Page 31...
  • Page 32: Fbb4 Optional Variable Speed Blower Installation Instructions

    FBB4 OPTIONAL VARIABLE SPEED BLOWER INSTALLATION Attention: Install blower assembly before connecting gas inlet 5. Insert blower assembly into interior, bottom of fireplace. supply line Position blower assembly behind gas valve, align notch on back of blower assembly with center screw on fireplace back Note: Junction box on right side of fireplace must be pre-wired at and push blower assembly against fireplace back.
  • Page 33 FBB4 OPTIONAL VARIABLE SPEED BLOWER INSTALLATION FBB4 BLOWER ASSEMBLY COMPLETE R7649 FAN CONTROL R4192 SPEED CONTROL KNOB R4186 SPEED CONTROL Figure 26 110 VOLT AC JUNCTION BOX Figure 27 19400-3-0406 Page 33...
  • Page 34: Junction Box Wiring Installation Instructions

    JUNCTION BOX WIRING INSTALLATION INSTRUCTIONS STANDARD MILLIVOLT VALVE MODELS CAUTION: ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH ALL LOCAL, CITY AND STATE BUILDING CODES. BEFORE MAKING THE ELECTRICAL CONNECTION, MAKE SURE THAT MAIN POWER SUPPLY IS DISCONNECTED.
  • Page 35: Optional Accessories

    OPTIONAL ACCESSORIES The following accessory parts can be obtained from your Empire Comfort Systems dealer. If you need additional information beyond what your dealer can furnish, contact Empire Comfort Systems Inc., Nine Eighteen Freeburg Ave., Belleville, Illinois 62220-2623. Accessory Description Model Number Fan Kit This fan kit was designed to provide forced air flow (for...
  • Page 36: Decorative Accessories

    DECORATIVE ACCESSORIES Decorative Louver Mission Decorative Louver Arch Decorative Louver Leaf Decorative Frame Rectangle Decorative Door Mission Decorative Door Leaf Decorative Door Plain with hinges Rectangle Rectangle Rectangle Decorative Frame Arch with Decorative Door Leaf Arch Decorative Door Mission Arch Decorative Door Plain Arch hinges Bottom Trim Frame...
  • Page 37: How To Order Repair Parts

    SERVICE NOTES HOW TO ORDER REPAIR PARTS Parts can be ordered only through your service person or dealer. For best results, the service person or dealer should order parts through the distributor. Parts can be shipped directly to the service person/dealer. All parts listed in the Parts List have a Part Number.
  • Page 38: Service Notes

    SERVICE NOTES Page 38 19400-3-0406...