Troubleshooting

problem
Charge Meter
Defective battery.
display reads
maximum.
No Charge Meter
1. Battery not connected.
reading.
2. No power to charger.
3. Battery cables not making connection.
4. Two-amp charge rate being used.
Charging current
1. Battery is partially charged.
not to full output.
2. Defective battery, will not
Charge Meter needle
1. Reversed battery connections.
moves up to full
charge, then drops
to zero. Makes
2. Battery is completely dead.
"clicking" noise.
3. Defective battery.
4. Charger is resetting itself
5. Circuit breaker is cycling.
Follow all safety precautions whenever diagnosing or servicing the tool.
Disconnect power supply before service.
Record product's Serial Number Here:
Note: If product has no serial number, record month and year of purchase instead.
Note: Internal parts are not user-serviceable and are not available.
Item 60431
possible causes
hold full charge.
after circuit overload.
For technical questions, please call 1-888-866-5797.
Likely Solutions
Check or replace battery.
1. Connect battery to charger. Charge Meter
will have no reading until battery attached.
2. Check power and cable outlet connections.
3. Clean battery cables and reset cable clamps.
4. None, meter will not indicate at this rate.
1. Continue charging battery.
2. Check and/or replace battery.
1. Double-check connection polarity.
If wrong, shut off charger and correct
cable lead connections.
2. Continue charging battery.
Charger will continue to reset itself until
the battery reaches a chargeable level.
3. Check and/or replace battery.
4. Wait until Charger automatically resets itself.
5. May be the wrong switch position.