Installation & Operating Manual
TO BOILER
FROM BOILER
Figure 4-2 Recommended domestic water piping
NOTICE
Please note that these illustrations are meant to show
system piping concept only, the installer is
responsible for all equipment and detailing required
by local codes.
1 6 |
SHOCK ARRESTOR
UNION
(TYPICAL)
ANTI-SCALD
MIXING VALVE
SST SERIES TANK
SHUTOFF VALVE
SHUTOFF
VALVE
SHUTOFF
VALVE
EXPANSION
TANK
TANK SENSOR / AQUASTAT
CHECK VALVE
RECIRCULATION
PUMP
DRAIN
( FIELD SUPPLY)
Indirect Fired Water Heaters Installation and Operating Manual
SHUTOFF
VALVE
BACKFLOW
PREVENTER