Quanser VoltPAQ-X2 User Manual page 12

Linear power amplifier
Hide thumbs Also See for VoltPAQ-X2:
Table of Contents

Advertisement

VoltPAQ X2 & X4 User Manual
Figure 9: Backside of VoltPAQ-X4 has 4 fuses.
There is one fuse per channel. So, for example, in the VoltPAQ-X2, there are 2 fuses. If
your voltage input is 100-132 VAC use the following fuses: Slow Blow 1.5A – Digikey part
number F2551-ND.
If your voltage input is 200VAC-240VAC use the following fuses: Slow Blow 1A –
Digikey part number F2543-ND
Remove the existing fuse by pushing inward and turning the fuse approximately 90 degrees,
then pull the cap out. Replace the fuse, push back in and twist to lock.