USER MANUAL VoltPAQ-X2/X4 Amplifiers Set Up and Configuration CAPTIVATE. MOTIVATE. GRADUATE.
Page 2
Fax: 1-905-940-3576 Printed in Markham, Ontario. For more information on the solutions Quanser Inc. offers, please visit the web site at: http://www.quanser.com This document and the software described in it are provided subject to a license agreement. Neither the software nor this document may be used or copied except as specified under the terms of that license agreement.
CONTENTS Presentation Components Specifications Fuse Installation Cable Nomenclature Troubleshooting Technical Support v 1.0 VOLTPAQ-X2 AND -X4 User Manual...
1 PRESENTATION The Quanser VoltPAQ-X2 and VoltPAQ-X4 are multi-channel, linear voltage-based power amplifiers. The VoltPAQ- X2 is a two-channel amplifier and the VoltPAQ-X4 is a four-channel system. They have the following features: • Supply up to ± 24 V and 4A continuous.
2 COMPONENTS The components on the front panel of the VoltPAQ-X2 and -X4 are depicted in Figure 2.1. Each component on the amplifier has an identification number that corresponds to a short description given in Table 2.1. Name Description Electrical...
Page 6
(a) Front panel (b) Back panel Figure 2.1: VoltPAQ-X4 components VOLTPAQ-X2 AND -X4 User Manual...
3 SPECIFICATIONS The specifications for the VoltPAQ-X2 and -X4 systems are given in Table 3.1 below. Specification VoltPAQ-X2 VoltPAQ-X4 Mass 4.4 kg 5.4 kg 0.39m × 0.33m × 0.10m 0.39m × 0.33m × 0.10m Dimension Minimum Amplifier Specifica- No load: -23.3 V to +21.8 V tions 2A load: -22.3 V to +20.8 V...
2. Make sure the amplifier power cable is disconnected. 3. Remove the fuse holder. There are three fuses in the VoltPAQ-X2 and five in the VoltPAQ-X4. To do this, push and twist the knob counter-clockwise and pull the fuse holder out as illustrated in Figure 4.1.
5 CABLE NOMENCLATURE Table 5.1 provides a description of the standard cables used in the wiring of the VoltPAQ-X2 and -X4. Cable Type Description 4-pin DIN to 6-pin This cable connects the amplifier to the load. To apply DIN motor cable...
Amplifier does not power up. • Make sure the power cable is firmly connected to the power connector on the back of the VoltPAQ-X2 and -X4. • Verify that the fuse is not burnt. If the fuse is burnt refer to Section 4.
7 TECHNICAL SUPPORT To obtain support from Quanser, go to http://www.quanser.com/ and click on the Tech Support link. Fill in the form with all the requested software and hardware information as well as a description of the problem encountered. Also, make sure your e-mail address and telephone number are included.
Page 12
QPID Board Quanser’s range of control peripherals includes amplifiers and data acquisition boards. They can be purchased separately to control educational or research-grade plants. Mix and match these peripherals with Quanser plants and control design software to accelerate control system design and implementation.