2. After preparing a through hole cut out a 25 mm (1'') deep recess for laying of the cables and the contact sockets connected to the
mounting plate.
The recommended recess profi le is shown in the drawing on the right.
max 200 mm(max 7 7⁄8")
max 90 mm
(max 3 9⁄16")
R100
(R4")
3. Install a telescopic air duct inside the wall. The telescopic air duct end must protrude to the distance A stated below:
Inside
4. Connect the mounting plate following the wiring diagram, page 12.
Prepare four fastening holes and fi x the mounting plate on the wall with fours 4x40 screws and 6x40 dowels (included into the delivery
set).
Align the telescopic air duct with respect to the mounting plate and fi ll the gaps between the wall and the telescopic air duct with a
mounting foam. The telescopic air duct must not protrude from the mounting plate surface.
VENTILATOR MOUNTING
While mounting several connected in series ventilators provide a
recess for the cable layout during the hole preparation to enable series
connection of several ventilators.
Outdoors
max A
Ventilator model
А, mm
TwinFresh Comfo RA-50
10 (
3
/
TwinFresh Comfo RA1-50
10 (
3
/
3
TwinFresh Comfo RA-50-2
10 (
/
3
TwinFresh Comfo RA1-50-2
10 (
/
9
'')
8
'')
8
5
'')-110(4
/
'')
8
16
5
'')-110(4
/
'')
8
16