The Faucet and Indicator Lights
Faucet and Electronics— The countertop faucet
dispenses filtered drinking water when opened.
It has a hand-operated, spring-loaded lever to
prevent waste. You can keep the faucet open by
pushing upward on the lever, until it locks
against the faucet spout.
To comply with plumbing codes, an air gap is
built into the faucet drain water connection.
The electronic faucet provides an integrated
TDS monitor. As water is taken from the faucet,
the indicator lights show how the Reverse
Osmosis system is operating to provide high
quality drinking water.
Flashing Green Light— The Reverse Osmosis
system is providing high quality drinking water.
If the Reverse Osmosis Filtration System Is Connected to Your Icemaker
Before you service the filter, change the filters, or purge the Filtration system, YOU MUST turn off the icemaker by raising
the feeler arm. Four hours after servicing your unit, lower the feeler arm to resume icemaking.
Purging the Reverse Osmosis System
Required upon initial installation or after the
Reverse Osmosis cartridge is replaced.
CAUTION: The Reverse Osmosis cartridge
contains a food grade preservative that should
be purged from the system before first use or
whenever the Reverse Osmosis cartridge is
replaced. The preservative will give product
water an unpleasant taste and odor.
Make sure all tubing connections are
1
tightened.
Make sure the red tank shutoff valve is
2
open. Turn on the water supply valve to
the Reverse Osmosis system.
In about four hours, pressure will start
3
to build in the Reverse Osmosis system.
At that time, carefully check all fittings
and tubing connections for any water
leaks. Correct leaks if any are found.
NOTE: If the Reverse Osmosis system is connected
to the refrigerator, this light will also flash when the
icemaker or water dispenser is in use. The green
light may stop flashing when the supply of Reverse
Osmosis water is nearly gone and flow from the
RO faucet decreases. This is a normal condition.
Flashing Amber "FILTER" Light— The prefilter and
postfilter cartridges need replacing. See the Care
and Cleaning section.
Flashing Amber "RO" Light— The Reverse Osmosis
cartridge is no longer removing at least 75% of the
TDS from the supply water and needs replacing.
See the Care and Cleaning section for Reverse
Osmosis cartridge replacement. NOTE: Disregard
initial or short periods (a few seconds) of the
flashing "RO" light. Long periods of limited or
non use can cause the TDS levels to temporarily
change.
Open the RO water faucet to drain the
4
storage tank.
Close the RO water faucet after draining.
5
Wait four hours until system has refilled.
Then open the RO faucet to drain the
storage tank.
Repeat the purging process for a total of
6
four times.
The system is ready to make product water
7
for your use.
Water supply valve
Drain line
Sink p-trap
Tank shutoff valve
1/4" tubing, marked
CLOSED
WATER SUPPLY
Electronics box
Battery pack
www.GEAppliances.com
RO product
water faucet
3/8" tubing, marked FAUCET
1/4" tubing, marked
1/4" BARB
Automatic shutoff
assembly
OPEN
Leadwires
5