The CMC100 automatically controls humidity in confined areas in many types of spaces, including facili-
ties, marine environments and in residential areas such as crawlspaces, attics and basements.
R E A D A N D S A V E T H E S E I N S T R U C T I O N S
WARNING
Read and understand manual before operating.
WARNING! Electric shock hazard, rotating fan, hot surface
hazards. Unplug unit before opening cover for cleaning or
servicing.
WARNING! Unit must be grounded.
• Keep motor and wiring dry. Keep out of standing water
and do not install in area likely to be subject to water intru-
sion. Do not expose to rain, water or snow.
• Insert three-prong plug on power cord into a matching
electrically grounded outlet. Do not use adapter. Never cut
off third prong. Do not use an extension cord.
• To reduce the risk of fire or electric shock, do not use this
unit with any solid-state speed control device.
FIRE HAZARD
• Keep away from open flames and heat sources.
• Do not use or store where vapors from gasoline, solvents,
thinners or other flammable materials may be present.

SAFETY INSTRUCTIONS

WARNING! Unplug unit before cleaning or servicing.
• Turn off unit and unplug before lifting or moving.
• Handle the unit carefully. Always operate the unit on a
stable, level surface. Do not drop, throw, or place where it
could fall. Rough treatment can damage the unit, and may
create a hazardous condition or
void the warranty.
• Inspect the power cord before
use. If cord is damaged, do not
use. Always grasp the plug (not
the cord) to unplug.
• The unit must be operated on a
115V/60 Hz circuit protected by a
07-01637F F391-A 2012-01 Warranty 07-01651
Owner's Manual
CMC100 Dehumidifier
DRI-EAZ PRODUCTS, INC.
15180 Josh Wilson Road, Burlington, WA 98233
Phone: 800-932-3030 Fax: (360) 757-7950
Upon receipt of your CMC100,
inspect it carefully for damage.
Set up and test unit in a tempo-
rary location for proper operation
before installing permanently.
http://cmc-100.dri-eaz.com
Ground Fault Interrupter (GFI) device.
• This appliance is not intended for use by persons (includ-
ing children) with reduced physical, sensory or mental ca-
pabilities, or lack of experience and knowledge, unless
they have supervision or have been given instruction con-
cerning use of the appliance by a person responsible for
their safety.
• Do not attempt to repair the unit. For Authorized Service
Centers, call Dri–Eaz Service at 800-932-3030.
INTRODUCTION
The CMC100 reduces humidity in enclosed structural environ-
ments by removing water vapor from the air. With proper use,
the CMC100 can help to dry out damp structural materials,
insulation, and contents, and maintain a healthy level of humid-
ity. Using the CMC100 may also prevent secondary damage
caused by high humidity.
How the CMC100 works
The CMC100 refrigerant dehumidifier uses a fan to draw moist
air in and condenses it into water that collects in a tray and is
automatically pumped out through a drain hose. A humidistat
automatically shuts the unit off when the desired level of hu-
midity has been achieved.
Features:
• Industrial-quality dehumidifier removes up to 70 pints (33
liters) of water per day.
• Automatic humidistat control means set-and-forget con-
venience.
• Ductable outlet for flexible application.
• Recessed handles for easy positioning in confined spac-
es.
• Interchangeable intake and output panels allow for use is
a wide variety of settings.
• Quiet operation and low power consumption.
NOTICE:
1
• The CMC100 has been awarded
the ENERGY STAR
INSTALLATION
Location
The CMC100 works best in an en-
closed area, as this creates a drying
chamber. Excessive infiltration of
damp air will increase operating time.
Dri-Eaz Products, Inc.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CMC100 and is the answer not in the manual?

Questions and answers

Summary of Contents for Dri-Eaz CMC100

  • Page 1: Safety Instructions

    Phone: 800-932-3030 Fax: (360) 757-7950 http://cmc-100.dri-eaz.com The CMC100 automatically controls humidity in confined areas in many types of spaces, including facili- ties, marine environments and in residential areas such as crawlspaces, attics and basements. R E A D A N D S A V E T H E S E I N S T R U C T I O N S Ground Fault Interrupter (GFI) device.
  • Page 2: Optional Configurations

    NOTICE: The CMC100 must be kept in an upright position. If it is necessary to place the unit on its side, such as during the installation of the feet, return the unit to the upright position and wait at least 10 minutes before starting the unit.
  • Page 3: Operation

    No user intervention hose higher than 3 ft. (1 m) above the top of the CMC100. is required. The CMC100 is controlled by an electronic touchpad hu- The CMC will automatically enter the DEFROST mode as midistat.
  • Page 4: Monthly Maintenance

    Inspect and Clean Filter Element Vacuum cleaner with crevice tool The CMC100 is equipped with a washable filter. Inspect the filter by removing the four filter door screws and sliding it out of the filter door panel (see Figure 2). If the filter shows excessive buildup, vacuum it clean and wash it in mild detergent.
  • Page 5 3 ft. (1 m) above the top of the CMC100. See “Keep Unit 7. Reattach the impeller housing to the pump assembly. Be- Level,”...
  • Page 6: Specifications

    Water removal at AHAM (80°F/60% RH) Power 6.2 amps, 115V FOR PARTS AND SERVICE CALL YOUR LOCAL DISTRIB- UTOR or the Dri-Eaz Service Department at 800-932-3030. Water removal efficiency 4.4 pts/kWh | 2.1 L/kWh www.dri-eaz.com (Energy factor) Condensate pump Included –...