The EB1400 is a highly transportable system, offering cooling, heating and dehumidification. It's ductable for spot cooling
WARNING
Read and understand manual before operating.
ELECTRIC SHOCK HAZARD
WARNING! Unit must be grounded.
Use indoors only.
Keep out of water.
Keep electrical components dry. If they get wet, allow
them to dry before using the EB1400.
Insert 3-prong plug on power cord into a matching
electrically grounded outlet. Never cut off third prong.
FIRE HAZARD
Keep air intakes clear of obstructions and dirt.
Reduced airflow can cause motor to overheat. Keep
away from draperies or other material that could block
air intakes. See maintenance instructions.
Keep air filter clean. Keep filter clear of clogging, oil,
grease or other contaminants that can be drawn into
the EB1400.

SAFETY INSTRUCTIONS

WARNING! Unplug unit before opening housing for
cleaning or servicing.
Turn off unit and unplug before lifting or moving.
Handle the unit carefully. Always operate the unit on a
stable, level surface. Do not drop, throw, or place
where it could fall. Rough treatment can damage the
unit, and may create a hazardous condition or void
the warranty.
07-01583B 06-07 Copyright 2007 Dri-Eaz Products, Inc.
Owner's Manual –
®
Dri-Eaz
EnviroBoss
DRI-EAZ PRODUCTS, INC.
15180 Josh Wilson Road, Burlington, WA USA 98233
Fax: (360) 757-7950 Phone US: (360) 757-7776
and directing conditioned air or heat into specific spaces.
Read And Save These Instructions
1400
www.dri-eaz.com
Inspect the power cord before use. If cord is
damaged, do not use. Replace with a cord of the
same type and amperage rating. Protect cord from
damage by turning off unit before unplugging. Always
grasp the plug (not pulling on the cord) to unplug.
The unit is designed to operate on a 115V/60 Hz,
15-amp circuit. Make sure that the electrical outlet is
grounded.
Secure during transport to prevent sliding and
possible injury to vehicle occupants.
Keep children away from unit. Be sure unit is
inaccessible to children when unattended.
Do not attempt to disassemble or repair the unit.
For Authorized Service Centers, go to
www.dri-eaz.com/HOWTOBUY
Service at 800-932-3030.
INTRODUCTION
The EB1400 is a versatile unit providing dehumidification, 1-ton
cooling with 470 CFM across the evaporator and 750 CFM
across the condenser, plus focused heating and ventilation.
The unit is ductable for spot cooling and directing conditioned
air or heat into specific spaces while filtering room air and
pumping out condensate.
FEATURES:
Ducts to and from unit for heating and cooling.
Note: Duct adapters for condenser inlet and outlet
and evaporator outlet. No duct adapter for evaporator
inlet
Refrigeration system that dehumidifies while it heats
or cools
Uniform 8" ducting size for all outlets
Digital temperature control
Durable rotomolded duct rings and housing
Wheel casters for ease of transport
1
or call Dri-Eaz

Advertisement

Table of Contents
loading

Summary of Contents for Dri-Eaz EnviroBoss 1400

  • Page 1: Safety Instructions

    Do not drop, throw, or place Wheel casters for ease of transport where it could fall. Rough treatment can damage the unit, and may create a hazardous condition or void the warranty. 07-01583B 06-07 Copyright 2007 Dri-Eaz Products, Inc.
  • Page 2: Parts Identification

    (Heat inlet back temperature. Rotomolded of unit) shell ESTING AND ROGRAMMING HERMOSTAT IGITAL ONTROLS Cord Digital screen pocket Left side Wheel casters Reset Back and Left Side View Down Cool Heat Auto 07-01583B 06-07 Copyright 2007 Dri-Eaz Products, Inc.
  • Page 3 Transport the unit on stairs or over rough surfaces upright on the Unimover or hand truck and hold in place using straps. WARNING! Take care when loading the unit on a hand truck; the unit could tip over resulting in personal 07-01583B 06-07 Copyright 2007 Dri-Eaz Products, Inc.
  • Page 4: Maintenance

    Use a clean 3M™ HAF Filter (below). Replace (114.3 cm x 63.5 cm x 78.7 filter every four months or earlier if necessary. For Parts and Service call your local distributor, or the Dri-Eaz Service Amperage 11.7 amps Department at 800-932-3030 or (360) 757-7776.
  • Page 5: Peligro De Descarga Eléctrica

    DRI-EAZ PRODUCTS, INC. 15180 Josh Wilson Road, Burlington, WA USA 98233 Fax: (360) 757-7950 Teléfono en EE.UU.: (360) 757-7776 www.dri-eaz.com El EB1400 es un sistema muy portátil, que ofrece enfriamiento, caldeo y deshumidificación. Está entubado a fin de ofrecer enfriamiento localizado y proporcionar aire acondicionado o calor en espacios específicos.
  • Page 6: Identificación De Piezas

    RUEBAS Y PROGRAMACIÓN DEL TERMOSTATO ONTROLES DIGITALES Pantalla digital Compartimient o cable de alimentación Lado izquierdo Reponer Bajar Subir Ruedecillas Ventilador Vista posterior izquierda Encendido 07-01583B 06-07 Copyright 2007 Dri-Eaz Products, Inc. Frío Apagado Calor Auto...
  • Page 7 B a la sección frontal o posterior temperatura sube por encima de 99 °F (37 °C), el termostato apaga la unidad. de la unidad para evitar que se dañe. Nota: No exponga 07-01583B 06-07 Copyright 2007 Dri-Eaz Products, Inc.
  • Page 8: Antes De Cada Uso

    Si usted procurar levantar la unidad. necesita ayuda adicional, entre en contacto con el departamento de servicio de Dri-Eaz en 800-932-3030 o Almacene con el lado izquierdo de la unidad contra la (360) 757-7776.
  • Page 9 Pas d'adaptateur de conduit soulever ou de le déplacer. pour l'entrée de l'évaporateur. • Manipuler l'appareil avec précaution. Toujours utiliser l'appareil sur une surface stable et plane. Ne pas 07-01583B 06-07 Copyright 2007 Dri-Eaz Products, Inc.
  • Page 10: Identification Des Pieces

    Écran numérique (entrée de chaleur au Coque dos de rotomoulée l'appareil) Remise à Poche du l’état initial cordon Haut Roulettes Côté gauche Ventilateur Vue arrière et latérale gauche Marche Froid Arrêt Chaleur Auto 07-01583B 06-07 Copyright 2007 Dri-Eaz Products, Inc.
  • Page 11 A (entrée de chaleur) en dehors de actuellement affichée correspond à la température la structure. ambiante. • : climatisation ponctuelle avec ESHUMIDIFICATION déshumidification par canalisation de la sortie D. Aucune canalisation n'est nécessaire pour déshumidifier l'ensemble de la zone. 07-01583B 06-07 Copyright 2007 Dri-Eaz Products, Inc.
  • Page 12: Entretien

    Si vous avez besoin dessus de l'eb 1400 et fixez-l'à l'Unimover ou davantage d'd'aide, entrez en contact avec le service après vente de Dri-Eaz à 800-932-3030 ou (360) à 757- remettez le camion avant d'essayer de soulever 7776.

This manual is also suitable for:

Eb1400

Table of Contents